Whitecroft Lighting CNSLD20 Starline Multiflex Instruction Manual

October 31, 2023
Whitecroft lighting

Whitecroft Lighting CNSLD20 Starline Multiflex

Product specification

Ambient Temperature -40 to +50°C
Voltage 24V DC
Ingress Protection IP00

Starline Multi-Flex Low Density LD

Starline Multi-Flex LD| Code| Lumens per reel| Watts per reel| LL/CW
---|---|---|---|---
5.6W/m, 542 lmIm. 2700K, 14m| SFLD127K| 7588| 78| 97
8.6W/m, 1084 lm/m, 2700K, 7m| SFLD227K| 7588| 60| 126
15.4W/m, 1616 lm/m, 2700K, 4.2m| SFLD327K| 6787| 65| 105
5.6Wim. 542 lm/m, 3000K, 14m| SFLD130K| 7588| 78| 97
8.6W/m, 1106 lm/m, 3000K, 7m| SFLD230K| 7742| 60| 129
15.4W m, 1684 lm/m, 3000K, 4.2m| SFLD330K| 7073| 65| 109
5.6W/m, 575 lm/m, 4000K, 14m| SFLD140K| 8050| 78| 103
8.6W/m, 1160 lm/m, 4000K, 7m| SFLD240K| 8120| 60| 135
15.4W,m, 1811 lm/m, 4000K, 4.2m| SFLD340K| 7606| 65| 117

Maximum number of LED reels per driver

Driver type| Code| 14m , 78W| 7m, 60W| 4.2m , 65W
---|---|---|---|---
Fixed output 20W| CNSLD20| 1 (max 2mJ| 1 (max 2m)| 1 (max 1m)
Fixed output 100W| CNSLD100| 1| 1| 1
Fixed output 180W| CNSLD180| 2| 2| 2
Fixed output 250W| CNSLD250| 2| 3| 3
Dali dimming SOW| CSFOYBO| 1 Imax 12m}| 1| 1
Dali dimming 150W| CSFDY150| 1| 2| 2

Note: Multiple reels should be wired in parallel, not in series

Information to consider before install:
  • Map layout abnd orientation before making any cuts.
  • Check polarity will be correct on loyout.
  • Allow 20-30mm extra trunking if being used so end caps can be fitted correctly.
  • Avoid mechanical stress on the tape, for example any sharp bends that may cause kinks in the tape.
  • Make sure surface is clean and smooth to get a strong bond.
  • Cut length 70mm
Soldering

Lead wires can be soldered on to the tape using the designated soldering pads, polarity MUST be checked before soldering. The maximum soldering time is 3 seconds and the solder temperature must not exceed 662°F (350°C). Once soldered the connection can be shrink wrapped using a heat gun(both not provided).

Quick Connect

The tape can connected using a Quick connector(not included see website). To apply peel back the back off the tape roughly 15-20mm and place it in open connector making sure the polarity is correct and the contact pads are engaged, once correct close the connector.

Surface preperation

If the tape is being applied directly to a surface make sure it is clean and smooth to get a goobond with the tape. If not use a alcohol solution to wipe down the surface and leave to dry. If the surface is not smooth then paint or primer can be added to help the bond.

GENERAL INFORMATION

  1. A qualified electrician, in accordance with IEE wiring regulations should carry out connection to mains wiring.
  2. Electrical Class I or II luminaire – see wiring diagrams below
  3. Ensure that the rated voltage and frequency requirements are compatible with the available mains supply.
  4. Cleaning of reflectors and lenses should be carried out using clean, soft and lint free cloths and anti-static cleaning fluid
  5. Do not carry out high voltage insulation test, i.e. 500/1000v this may damage internal components.

General Information

CUSTOMER SUPPORT

TECHNICAL SUPPORT

Telephone: 0161 331 5700
E-mail: technical@whitecroftlight.com
http://www.whitecroftlighting.com/

Whitecroft Lighting Limited

Burlington Street, Ashton-under-Lyne, Lancashire OL7 0AX
Telephone 0161 330 6811 Facsimile: 0161 331 5855
Registered No. 3848973 England Registered Office: As above

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Whitecroft lighting User Manuals

Related Manuals