CDA ECP72SS ECP & ECN Extractors User Manual
- June 5, 2024
- CDA
Table of Contents
ECP & ECN Extractors
User Manual
Important
The CDA Group Ltd cannot be held responsible for injuries or losses caused by
incorrect use or installation of this product. Please note that CDA reserve
the right to invalidate the guarantee supplied with this product following the
incorrect installation or misuse of the appliance or use in a commercial
environment.
This appliance is not designed to be used by people (including children) with
reduced physical, sensorial or mental capacity, or who lack experience or
knowledge about it, unless they have had supervision or instructions on how to
use the appliance by someone who is responsible for their safety.
Under no circumstances should any external covers be removed for servicing or
maintenance except by suitably qualified personnel.
Appliance information:
Please enter the details on the appliance rating plate below for reference, to
assist CDA Customer Care in the event of a fault with your appliance and to
register your appliance for guarantee purposes.
Appliance Model :
Serial Number :
Declarations of Conformity:
This appliance has been manufactured to comply with all EU & UK statutory
requirements and complies with all applicable legislation and the following
European Directives:
- The Low Voltage Directive 2014/35/EU
- Electromagnetic Compatibility Directive 2014/30/EU.
The product has been marked with the UKCA and CE symbols. This appliance is
marked according to the European directive 2004/104/EC on Waste Electrical and
Electronic equipment (WEEE). I
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH
EC DIRECTIVE 2012/19/EU.
At the end of its working life, the product must be taken to a special local
authority waste collection center or to a dealer providing appliance recycling
services.
Disposing of a household appliance separately avoids possible negative
consequences for the environment and health. It also enables the constituent
materials to be recovered, saving both energy and resources. As a reminder of
the need to dispose of household appliances separately, the product is marked
with a crossed-out wheeled dustbin.
Please note:
- Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system.
- Do not vent the extractor into an attic or loft space.
- Only house the extractor in rooms with adequate ventilation. Remember that the extractor is powerful and whatever air is extracted needs to be replaced.
- Do not tile the extractor in. It should be removable for service or maintenance.
- Do not use silicone sealant to secure the hood to the wall.
- You must be able to isolate the extractor from the mains electrical supply after installation.
- This extractor has been designed to be used in a room with a volume of less than 36m3.
- Steam cleaners must not be used when cleaning this appliance
- The performance of your extractor will vary depending on a number of factors. These inthe clude type of extraction, length of ducting, room volume, ventilation available and cleanliness of the filters.
Using your Extractor
For best performance, you should switch on the extractor 15 minutes before
starting to cook and leave it to run for approximately 15 minutes after the
end of cooking.
Control Panel
A – Power off button
B – Speed level buttons
C – Light button
To switch the extractor light on or off
- Press button “C”.
To switch on the extractor or to change the speed at any time whenthe extractor is running
- Press the relevant “B” button for the first, second or third speed level as required.
To switch the extractor off
- Press the “A” button.
Care and Maintenance
IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR
WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY
Cleaning
You should use a non-abrasive cleaner. Any abrasive cleaner (including Cif)
will scratch the surface and could erase the control panel markings.
You can clean your extractor effectively by simply using a dilute solution of
water and mild detergent and drying to a shine with a clean cloth, for
example, a microfibre cloth. Cleaning the grease filter
should be kept clean to minimize the risk of fire. At least once a month you
should remove and clean the grease filter with hot soapy water. You can also
wash the grease filter in a dishwasher, ensuring that you place it in an
upright position to prevent damage from other items in the dishwasher.
To remove the grease filter, push in the button on the handle and then pull
down on the filter at the front as shown in figure 2. When you have released
it at the front, then you can pull the filter out completely. After rinsing
and drying, reassemble the grease filter to the hood by reversing the removal
process.
Please note:
Cleaning the grease filter in the dishwasher may lead to discoloration. This
is normal and does not constitute a fault with the appliance.
Changing the charcoal filter (re-circulating only) To ensure the best
performance of your extractor, you should replace the charcoal filter every
four to six months, depending on use.To attach a new charcoal filter, first,
remove the grease filters as described above. Offer up the charcoal filter so
that the magnetic pins are facing upwards, one to the rear and one to either
side. The filter will be held in place by magnetic force. Finally, replace the
grease filters.
Mains Electricity Connection
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON,
USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED
BY A 3A FUSE.
We recommend that the appliance is connected by a qualified electrician, who
is a member of the N.I.C.E.I.C. and who will comply with the I.E.T. and local
regulations.
The wires in the mains lead of this appliance are colored in accordance with
the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
As the colors of the wires in the mains lead for the appliance may not
correspond with the colored markings identifying the terminals connecting to
the fuse spur, proceed as follows:
- The wire which is colored green and yellow must be connected to the terminal marked E (Earth) or colored green.
- The wire which is colored blue must be connected to the terminal marked N (Neutral) or colored black.
- The wire which is colored brown must be connected to the terminal marked L (Live) or colored.
Note: Use a 3A Fuse.
Assembly and electrical connection should be carried out by specialized
personnel.
When installing this product we recommend you seek the help of another
individual.
LED lighting
In case of malfunction of the illumination system contact the technical
service. Replaceable (LED only) light source by professional Contact details
is on page 10
Electrical Information
Mains electrical voltage: 230 – 240Vac
Total rated power consumption: 104W
Troubleshooting
Please note:
Your extractor is equipped with a motor protection device that will switch off
the motor to prevent damage from overheating. This may happen during cooking
when most or ll f the zones/burners are being used simultaneously, or if your
extractor is installed incorrectly, lower than the recommended height.
This is normal, and the extractor will work again once the motor has cooled
sufficiently.
If your extractor is not working:
- Check that the mains supply has not been switched off.
- Check that the fuse in the spur has not blown.
Contact CDA Customer Care
A: Customer Care Department, The CDA Group Ltd, Harby Road, Langar,
Nottinghamshire, NG13 9HY
T: 01949 862 012
F: 01949 862 003
E: customer.care@cda.eu
W: www.cda.eu
Mounting your Extractor
When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must exceed 600mm for ceramic and solid plate hobs and 550mm for induction Hobs.
When the extractor is to be installed above a gas hob, the minimum distance between the hob and extractor must exceed 650mm.
| EXP| ECN
---|---|---
A| 53| 72
B| 226| 226
C| 512| 512
D| 105| 105
E| 75| 75
F| 73| 73
If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 650mm, then that is the distance that should be observed; this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported under RIDDOR (the height should be measured from the top of the burners).
IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 650mm. The width of any hob must not be greater than the width of the extractor installed above it.
Installation
The metal casing of this appliance has been coated with a preservative to protect it during transport and storage. This should be removed during installation by using a non-abrasive stainless steel cleaner. Always follow the instructions given with the cleaner being used.
Ducting and Ventilation
For best performance and lowest noise output, we recommend the use of 125mm
ducting. 100mm ducting may be used but this will reduce performance and
increase the noise f the extractor. The ducting used should be rigid circular
pipe and must be manufactured from fire retardant material, produced to BS 476
or DIN are as follows:
- 4 meters with 1 x 90° bend.
- 3 meters with 2 x 90° bends.
- 2 meters with 3 x 90° bends.
Longer ducting can be used but the performance of the extractor will likely be reduced.
|
---|---
Tools required| Mark wall as required (see table 2)
|
Drill holes| Fit wall fixings and top screws – Ensure that any fixings you
use are appropriate for the wall type.
|
Secure hood (tighten all screws)| Fit ducting adaptor
IMPORTANT SAFETY WARNING: ONLY USE THE SCREWS PROVIDED WITH THE EXTRACTOR TO MOUNT` THE DUCTING ADAPTOR. THE USE OF LONGER SCREWS MAY CAUSE DAMAGE TO THE INTERNAL WIRING WHICH WILL NOT BE COVERED BY THE WARRANTY.
|
---|---
Mount upper and lower chimney brackets| Fix ducting (seal joint)
|
Mount the chimney| Adjust and secure the chimney
E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.
Energy Efficiency Information
Attribute| Symbol| Value| Units
Model Identification| | ECN62/72/92| ECP62/72/82| ECP92/102/112|
Annual Energy Consumption| AECHOOd| 60| 60| 60| kWh
Time increase factor| f| 2.| 2.| 2.|
Fluid Dynamic Efficiency| FDEHOOd| 10.| 10.| 9.|
Energy Efficiency Index| EEIHOOd| 88.| 88.| 88.|
Measured airflow at Best Efficiency Point| QB| 228.| 228.| 219.| m3/h
Measured Pressure at Best Efficiency Point| PBEM| 141.0| 141.0| 137.0| Pa
Maximum airflow| °MAX| 391.| 391.| 377.| m3/h
Measured electric power at Best Efficiency Point| WBEP| 92.| 92.| 92.| W
Nominal lighting power| WL| 4| 4| 4| W
Average illumination of the lighting system on the cooking surface| Eddie|
475| 475| 475| Lux
Measured power consumption in standby| Ps| N/A| N/A| N/A| W
Measured power consumption off mode| Po| 0.0| 0.0| 0.0| W
Sound power level| L| 60.0| 60.0| 60.0| dBA
Grease Filter Efficiency| GFEHOOd| 71.4 (D)| 71.4 (D)| 76.7 (C)| %
Lamp efficiency| LaHood| 118 (A)| 118 (A)| 118 (A)| %
E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.
For service or queries relating to your product please contact:
The Customer Care Department on 01949 862 012 or email
customer.care@cda.eu
Customer Care Department. The CDA Group Ltd, Harby Road, Langar,
Nottinghamshire, NG13 9HY
T: 01949 862 012 F: 01949 862 003 E:
customer.care@cda.eu
For more information please contact:
The Sales Department on 01949 862 010 or email
sales@cda.eu
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>