CAMDEN DOOR CONTROLS CX-91S-06-TDS Single Door Magnetic Lock Instruction Manual
- June 12, 2024
- CAMDEN DOOR CONTROLS
Table of Contents
CAMDEN DOOR CONTROLS CX-91S-06-TDS Single Door Magnetic Lock
Product Information
The CX-91S TDS Series Magnetic Locks are electric locking mechanisms designed for access control applications. They are equipped with a special locking arrangement component that provides enhanced security. These locks are suitable for use with electrified locks, relays, and timers. The CX-91S TDS Series Magnetic Locks comply with UL 1034 and UL 294 standards for burglary- resistant electric locking mechanisms, as well as ULC S533-15 standard for access and egress.
Specifications
- Static Strength: CX-91S-06-TDS – 600 lbs., CX-91S-12-TDS – 1200 lbs.
- Dynamic Strength: CX-91S-06-TDS – 50 ft-lb, CX-91S-12-TDS – 70 ft-lb
- Voltage Input: 12/24V DC
- Current Draw: CX-91S-06-TDS – 510mA/285mA, CX-91S-12-TDS – 500mA/265mA
- Dimensions (Body): CX-91S-06-TDS – 9-7/8W x 2H x 1D (250mm x 50mm x 25mm), CX-91S-12-TDS – 10-1/2W x 2-5/8H x 1-1/2D (266mm x 67mm x 39mm)
- Dimensions (Armature Plate): CX-91S-06-TDS – 7-5/32W x 1-3/4H x 15/32D (182mm x 44mm x 12mm), CX-91S-12-TDS – 7-9/32W x 2-13/32H x 5/8D (185mm x 61mm x 16.5mm)
- Endurance: 250,000 cycles
Performance Levels
- Destructive Attack: Level I
- Line Security: Level I
- Standby Power: Level I
- Endurance: Level IV (Relay Source #2 and #3)
Product Usage Instructions
Basic Installation Concept & Accessories
Refer to Figure 1 for a general installation concept and the required accessories.
Installation Steps
- Drill the armature plate holes in the door using the provided sticker template.
- Attach the armature plate to the door using the hardware provided (refer to Figure 2.3).
- With the door closed, mark the door frame at the edge of the armature to align the electromagnet properly.
- Attach the mounting plate to the door frame using the self-tapping screws provided. Align the mounting plate with the mark from Step 3.
- Insert the wires through the hole in the mounting plate and into the electromagnet unit. Attach the electromagnet unit to the mounting plate with the Allen head fixing screw.
- Screw in the anti-tamper nuts to prevent unauthorized access and fully tighten the fixing screw using a T Handle Allen Key.
- The electromagnetic lock must be installed in a secured or protected area.
- Follow the typical wiring method according to CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.
- Note: Install the lock in an indoor dry location.
- Use caution when changing factory default settings.
- It is recommended to apply a light coat of silicon lubricant to the mating surface on a monthly basis to prevent rust.
- Refer to the manufacturer’s instructions provided with each unit for further guidance.
NOTICE: All models are recognized to comply with UL 294 and ULC S533-15 standards for access and egress.
CX-91S TDS Series Magnetic Locks
INSTALLATION INSTRUCTIONS
SPECIFICATIONS
| CX-91S-06- TDS| CX-91S-12- TDS
---|---|---
Static Strength| 600 lbs. (Factory Tested) 500 lbs. (UL Verified)|
1200 lbs. (Factory Tested) 1000 lbs. (UL Verified)
Dynamic Strength| 50 ft-lb| 70 ft-lb
Voltage Input| 12/24V DC| 12/24V DC
Current Draw| 510mA/285mA| 500mA/265mA
Dimensions (Body)| 9-7/8″W x 2″H x 1″D
(250mm x 50mm x 25mm)
| 10-1/2″W x 2-5/8″H x 1-1/2″D
(266mm x 67mm x 39mm)
Dimensions (Armature Plate)| 7-5/32″W x 1-3/4″H x 15/32″D
(182mm x 44mm x 12mm)
| 7-9/32″W x 2-13/32″H x 5/8″D
(185mm x 61mm x 16.5mm)
Endurance| 250 000| 250 000
Performance Levels
- Destructive Attack = Level I ****
- Line Security = Level I ****
- Standby Power = Level I ****
- Endurance = Level IV ****
- ( Relay Source #2 and #3 )
BASIC INSTALLATION CONCEPT & ACCESSORIES (FIGURE 1)
INSTALLATION
- Drill the armature plate holes in the door using the sticker template
- Attach the armature plate to the door with the hardware provided as per Figure 2.3.
- With the door closed, mark the door frame at the edge of the armature in order to properly align the electromagnet to the armature.
- Attach the mounting plate to the door frame using the self- tapping screws provided. Align the mounting plate with the mark from Step 3.
- Insert the wires through the hole in the mounting plate and into the electromagnet Attach the electromagnet unit to the mounting plate with the Allen head fixing screw.
- Screw in the anti-tamper nuts to prevent unauthorized access and make sure to fully tighten the fixing screw with proper A “T” Handle Allen Key.
- The electromagnetic lock must be installed in accordance with the following :
- Life Safety Code ANSI / NFPA
- Local Authority having
- Manufacturer’s installation instructions provided with each
- The power supply units must be mounted inside the secured or protected
- Typical wiring method shall be in accordance with CSA 1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.
Note: Install in indoor dry location. Use caution when changing factory default setting. It is recommended to apply a light coat of silicon lubricant to the mating surface on a monthly basis to prevent rust. Manufacturer’s Instructions provided in each unit.
NOTICE:
All models are recognized to:
UL 294 and ULC S533-15 : Standard for Access & Egress.
Models CX-91S-06 & CX-91S-12 are listed to:
UL 1034, Standard for Burglary-Resistant Electric Locking Mechanism.
UL 294, Access Control System Units
** Value not verified by UL.
Remark:
All drawings shown are for illustration purpose only. Actual products may vary due to product enhancement.
TROUBLESHOOTING
- Sensor not functioning:
- Improper attachment of electromagnet and armature
- Modification of the PCB
- Door not locked:
- Incorrect wiring or no power from a power supply
- Reduced holding force:
- Poor contact of electromagnet and armature
- Be sure the armature is loose enough that it can fully contact the electromagnet along the entire length
- The mating surface is dusty or damaged
- Improper input voltage or wire
IMPORTANT! Set the jumper position according to the power input correctly before switching ON the power.
REGULAR INSTALLATION GUIDE (FIGURE 2)
LZ BRACKET FOR IN-SWING DOOR INSTALLATION GUIDE (FIGURE 3)
Call : 1.877.226.3369 / 905.366.3377
Visit : www.camdencontrols.com
File: CX-91S-TDS-Series_Manual_R4.indd Rev.: 11/12/20
Part No.: 40-82B217