CAMDEN DOOR CONTROLS CX-91S-06-TDS Single Door Magnetic Lock Instruction Manual

June 12, 2024
CAMDEN DOOR CONTROLS

CAMDEN-DOOR-CONTROLS-LOGO

CAMDEN DOOR CONTROLS CX-91S-06-TDS Single Door Magnetic Lock

CAMDEN-DOOR-CONTROLS-CX-91S-06-TDS-Single-Door-Magnetic-Lock-
PRODUCT

Product Information

The CX-91S TDS Series Magnetic Locks are electric locking mechanisms designed for access control applications. They are equipped with a special locking arrangement component that provides enhanced security. These locks are suitable for use with electrified locks, relays, and timers. The CX-91S TDS Series Magnetic Locks comply with UL 1034 and UL 294 standards for burglary- resistant electric locking mechanisms, as well as ULC S533-15 standard for access and egress.

Specifications

  • Static Strength: CX-91S-06-TDS – 600 lbs., CX-91S-12-TDS – 1200 lbs.
  • Dynamic Strength: CX-91S-06-TDS – 50 ft-lb, CX-91S-12-TDS – 70 ft-lb
  • Voltage Input: 12/24V DC
  • Current Draw: CX-91S-06-TDS – 510mA/285mA, CX-91S-12-TDS – 500mA/265mA
  • Dimensions (Body): CX-91S-06-TDS – 9-7/8W x 2H x 1D (250mm x 50mm x 25mm), CX-91S-12-TDS – 10-1/2W x 2-5/8H x 1-1/2D (266mm x 67mm x 39mm)
  • Dimensions (Armature Plate): CX-91S-06-TDS – 7-5/32W x 1-3/4H x 15/32D (182mm x 44mm x 12mm), CX-91S-12-TDS – 7-9/32W x 2-13/32H x 5/8D (185mm x 61mm x 16.5mm)
  • Endurance: 250,000 cycles

Performance Levels

  • Destructive Attack: Level I
  • Line Security: Level I
  • Standby Power: Level I
  • Endurance: Level IV (Relay Source #2 and #3)

Product Usage Instructions

Basic Installation Concept & Accessories

Refer to Figure 1 for a general installation concept and the required accessories.

Installation Steps

  1. Drill the armature plate holes in the door using the provided sticker template.
  2. Attach the armature plate to the door using the hardware provided (refer to Figure 2.3).
  3. With the door closed, mark the door frame at the edge of the armature to align the electromagnet properly.
  4. Attach the mounting plate to the door frame using the self-tapping screws provided. Align the mounting plate with the mark from Step 3.
  5. Insert the wires through the hole in the mounting plate and into the electromagnet unit. Attach the electromagnet unit to the mounting plate with the Allen head fixing screw.
  6. Screw in the anti-tamper nuts to prevent unauthorized access and fully tighten the fixing screw using a T Handle Allen Key.
  7. The electromagnetic lock must be installed in a secured or protected area.
  8. Follow the typical wiring method according to CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.
  9. Note: Install the lock in an indoor dry location.
  10. Use caution when changing factory default settings.
  11. It is recommended to apply a light coat of silicon lubricant to the mating surface on a monthly basis to prevent rust.
  12. Refer to the manufacturer’s instructions provided with each unit for further guidance.

NOTICE: All models are recognized to comply with UL 294 and ULC S533-15 standards for access and egress.

CX-91S TDS Series Magnetic Locks

INSTALLATION INSTRUCTIONS

SPECIFICATIONS

| CX-91S-06- TDS| CX-91S-12- TDS
---|---|---
Static Strength| 600 lbs. (Factory Tested) 500 lbs. (UL Verified)| 1200 lbs. (Factory Tested) 1000 lbs. (UL Verified)
Dynamic Strength| 50 ft-lb| 70 ft-lb
Voltage Input| 12/24V DC| 12/24V DC
Current Draw| 510mA/285mA| 500mA/265mA
Dimensions (Body)| 9-7/8″W x 2″H x 1″D

(250mm x 50mm x 25mm)

| 10-1/2″W x 2-5/8″H x 1-1/2″D

(266mm x 67mm x 39mm)

Dimensions (Armature Plate)| 7-5/32″W x 1-3/4″H x 15/32″D

(182mm x 44mm x 12mm)

| 7-9/32″W x 2-13/32″H x 5/8″D

(185mm x 61mm x 16.5mm)

Endurance| 250 000| 250 000

Performance Levels

  • Destructive Attack = Level I ****
  • Line Security = Level I ****
  • Standby Power = Level I ****
  • Endurance = Level IV ****
  • ( Relay Source #2 and #3 )

BASIC INSTALLATION CONCEPT & ACCESSORIES (FIGURE 1)CAMDEN-DOOR-CONTROLS-
CX-91S-06-TDS-Single-Door-Magnetic-Lock-FIG- \(1\)

INSTALLATION

  1. Drill the armature plate holes in the door using the sticker template
  2. Attach the armature plate to the door with the hardware provided as per Figure 2.3.
  3. With the door closed, mark the door frame at the edge of the armature in order to properly align the electromagnet to the armature.
  4. Attach the mounting plate to the door frame using the self- tapping screws provided. Align the mounting plate with the mark from Step 3.
  5. Insert the wires through the hole in the mounting plate and into the electromagnet Attach the electromagnet unit to the mounting plate with the Allen head fixing screw.
  6. Screw in the anti-tamper nuts to prevent unauthorized access and make sure to fully tighten the fixing screw with proper A “T” Handle Allen Key.
  7. The electromagnetic lock must be installed in accordance with the following :
    • Life Safety Code ANSI / NFPA
    • Local Authority having
    • Manufacturer’s installation instructions provided with each
    • The power supply units must be mounted inside the secured or protected
  8. Typical wiring method shall be in accordance with CSA 1, Canadian Electrical Code, Part I, Safety Standard for Electrical Installations, Section 32.

Note: Install in indoor dry location. Use caution when changing factory default setting. It is recommended to apply a light coat of silicon lubricant to the mating surface on a monthly basis to prevent rust. Manufacturer’s Instructions provided in each unit.

NOTICE:

All models are recognized to:

UL 294 and ULC S533-15 : Standard for Access & Egress.

Models CX-91S-06 & CX-91S-12 are listed to:

UL 1034, Standard for Burglary-Resistant Electric Locking Mechanism.

UL 294, Access Control System Units

** Value not verified by UL.

Remark:

All drawings shown are for illustration purpose only. Actual products may vary due to product enhancement.

TROUBLESHOOTING

  1. Sensor not functioning:
    • Improper attachment of electromagnet and armature
    • Modification of the PCB
  2. Door not locked:
    • Incorrect wiring or no power from a power supply
  3. Reduced holding force:
    • Poor contact of electromagnet and armature
    • Be sure the armature is loose enough that it can fully contact the electromagnet along the entire length
    • The mating surface is dusty or damaged
    • Improper input voltage or wire

CAMDEN-DOOR-CONTROLS-CX-91S-06-TDS-Single-Door-Magnetic-Lock-FIG-
\(2\)IMPORTANT! Set the jumper position according to the power input correctly before switching ON the power.

REGULAR INSTALLATION GUIDE (FIGURE 2)CAMDEN-DOOR-CONTROLS-CX-91S-06-TDS-
Single-Door-Magnetic-Lock-FIG- \(3\) CAMDEN-DOOR-CONTROLS-CX-91S-06-TDS-Single-Door-
Magnetic-Lock-FIG- \(4\) CAMDEN-DOOR-CONTROLS-CX-91S-06-TDS-Single-Door-Magnetic-Lock-FIG-
\(5\)

LZ BRACKET FOR IN-SWING DOOR INSTALLATION GUIDE (FIGURE 3)CAMDEN-DOOR-
CONTROLS-CX-91S-06-TDS-Single-Door-Magnetic-Lock-FIG-
\(6\) CAMDEN-DOOR-CONTROLS-CX-
91S-06-TDS-Single-Door-Magnetic-Lock-FIG- \(7\)

Call : 1.877.226.3369 / 905.366.3377

Visit : www.camdencontrols.com

File: CX-91S-TDS-Series_Manual_R4.indd Rev.: 11/12/20

Part No.: 40-82B217

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CAMDEN DOOR CONTROLS User Manuals

Related Manuals