Aseptico ADC-01P Portable Pediatric Dental Chair User Manual
- June 12, 2024
- Aseptico
Table of Contents
OPERATION AND
MAINTENANCE MANUAL
Portable Pediatric Dental Chair
ADC-01P (gray)
ADC-01P-RED (red)
ADC-01P-BLU (blue)
P.O. Box 1548 • Woodinville, WA 98072-1548
1-800-426-5913 •
425-487-3157 • Fax:
360-668-8722
Email: info@aseptico.com • Internet:
www.aseptico.com
Introduction
PURPOSE:
Aseptico’s Portable Pediatric Dental Chair provides adolescent patient seating
for field dentistry and medical treatment and is fully adjustable from upright
to supine positions.
The chair is built with a high-strength steel frame and rugged replaceable
vinyl coverings.
Available in three colors:
- Gray (ADC-01P)
- Red (ADC-01P-RED)
- Blue (ADC-01P-BLU)
PERFORMANCE CHARACTERISTICS:
Dimensions
Chair- Folded: 37” x 23” x 9.5”
Extended: 67” x 28” x 46”
Soft carrying case: 36” x 24” x 10”
Weight
Chair only: 30 lbs.
In soft carrying case: 34.5 lbs.
Maximum Load Capacity: Approx. 300 lbs.
Range of Positions
Minimum Seat Height: 11”
Maximum Seat Height: 22”
Backrest: Adjustable from upright (vertical) to supine (horizontal) positions
Footrest: Adjustable from upright (vertical) to supine (horizontal) positions
ITEMS FURNISHED
Portable Pediatric Dental Chair (ADC-01P, ADC-01P-RED or ADC-01P-BLU)
Soft padded carrying case with handles
Operation and Maintenance Manual
CHAIR SET-UP:
-
Remove the chair from its carrying case and set it on the floor, legs down, in its folded position.
-
Rotate the chair up onto one side and remove the leg adjustment pins from their storage pouch underneath the chair seat. (Fig. 1)
-
Standing in front of the chair, put your toe on one of the front chair legs and lift up on the backrest and front seat portion. Raise chair seat to desired height. Lock in place by inserting leg adjustment pins through chair leg tube and into adjustment link on the right and left side of the chair. (Fig. 2)
-
When the chair has been raised and the height set, the foot and leg portion should be folded forward, out horizontally. It will stop in the horizontal position. (Fig. 3)
-
Insert right and left arm sling pins into holes on the sides of the seat frame. (Fig. 4)
-
Complete set-up by positioning backrest and placing headrest at the proper height on the front side of backrest.
CHAIR ADJUSTMENTS:
-
Seat Height- The chair seat height can be set at any of the five preset settings. Without a patient in the chair, put your toe on one of the front chair legs and lift up slightly on the chair seat. While lifting and holding seat, remove the leg adjustment pin from the right and left side. Align link with tube hole in any of the five positions and lock in place by inserting the pin and chain assembly. (see Fig. 2)
-
Backrest- The backrest may be set in any position from upright to full supine. To change the position of the backrest, simply lift the chrome friction lever on the back side of the backrest, lower backrest, then release lever to lock. (see Fig. 5)
WARNING
NEVER LOWER THE BACKREST WHEN A PATIENT IS IN THE CHAIR WITHOUT COMPLETELY SUPPORTING THEIR WEIGHT FIRST.
To return the backrest to an upright position, lift backrest to desired position. Backrest will automatically lock in place. (Fig. 5) -
Footrest- The footrest may be positioned in the normal horizontal operating position, or allowed to hang down vertically so a patient can be seated in a sitting position.
To release footrest into the vertical position, first fold toe section inward, then lift slightly on footrest section. While lifting, pull the black knobs on each side of the chair frame to release and push footrest down into the vertical position. Lock in the vertical position by snapping holding strap around the chair leg frame.
To reposition footrest in the horizontal position, unsnap holding strap from frame, lift footrest to the horizontal position until it locks, then unfold toe section out to horizontal. (Fig. 6)
-
Headrest- The headrest slides freely on its mounting strap and can be positioned at different heights for different size patients.
COLLAPSING THE CHAIR:
WARNING
NEVER FORCE THE CHAIR INTO THE COLLAPSED POSITION.
FORCING THE CHAIR DOWN WITHOUT RELEASING THE BACKREST ADJUSTMENT LEVER MAY
BEND THE ADJUSTMENT ASSEMBLY AND WILL VOID THE WARRANTY.
- Fold toe and then leg sections onto seat as it was originally stored.
- Pull arm slings out of the holes in the chair frame.
- Put your toe onto one of the front chair legs and lift up slightly on the seat, then remove height adjustment pins. While supporting chair weight, let the chair fold down toward the floor.
- As the chair folds down, release the backrest adjustment lever until the chair collapses completely. Rotate the chair up onto one side and insert the leg adjustment pins into their storage pouch underneath the chair seat.
- Fold the arm slings and headrest onto the chair and place folded chair into carrying case.
CLEANING AND MAINTENANCE:
Although bleach, when diluted to <10% and wiped clean immediately could be used, it is not recommended. The use of barrier covers and mild cleaning solutions is recommended as the primary asepsis approach on chair and stool upholstery instead of relying on chemicals. The use of barriers greatly extends the life of chair and stool upholstery and can be replaced between patients.
WARNING
NEVER SIT ON THE EDGE OF THE SITTING SURFACE.
ALWAYS SIT IN THE CENTER OF THE SEAT.
PARTS LIST
| Item| ADC-01P| ADC-01P-RED| ADC-01P-BLU| Quantity
---|---|---|---|---|---
1| Seat Cover Assembly| 460451| 460451-01| 462551| 1
2| Armrest Right| 460447| 460447-01| 462550| 1
3| Armrest Left| 460447| 460447-01| 462550| 1
4| Cover, backrest| 462710| 461845| 462711| 1
5| Strap, headrest| 460449| 461847| 462538| 1
6| Screw, #8×5/8″ Chrome SEMS| 510239| <—| <—| 8
7| Headrest, pillow assembly| 462712| 461846| 461713| 1
8| Armrest support rod assembly| 460444-08| <—| <—| 2
9| Tie Wrap, 30″| 510135| <—| <—| 6
10| Tie Wrap, 13″| 510134| <—| <—| 3
11| Strap, leg| 460448| 461848| 462539| 1
12| C/S, 1/4-20×1″ BtnSoc S/S| 510294| <—| <—| 1
13| Hinge, back support| 460382-08| <—| <—| 1
14| Nut, 1/4-20 Nyloc S/S| 510296| <—| <—| 8
15| Back Support Assembly| 330088| <—| <—| 1
16| Leg adjustment link| 460097-08| <—| <—| 2
17| Hole plug, 1/4″ black| 510201| <—| <—| 2
18| Endcap, 1″ domed| 850026| <—| <—| 4
19| Leg Assembly, inside| 330099| <—| <—| 1
20| Leg Assembly, outside| 330101| <—| <—| 1
21| Bolt, 5/16-18 Grade 5 carriage| 510242| <—| <—| 2
22| Washer, 5/16 Flat S/S| 510266| <—| <—| 4
23| Nut, 5/16-18 Nyloc S/S| 510126| <—| <—| 2
24| Endcap, 1″ insert| 510204| <—| <—| 2
25| C/S, 114-20×1-1/4″ BtnSoc S/S| 510295| <—| <—| 3
26| Toe Frame Assembly| 330091| <—| <—| 1
27| Nut, 5/16-18 hex S/S| 510103| <—| <—| 2
28| Foam, seat pad| 460576| <—| <—| 1
29| Spring Pin, 1/4×3/4″ S/S| 510251| <—| <—| 2
30| Leg Frame Assembly, cmpl| 330093-08| <—| <—| 1
31| Knob, 5/16-18 insert cornet| 850025| <—| <—| 2
32| Spring, .420Dx.038Wx.875L comp.| 510233| <—| <—| 2
33| CIS, 5/16-18×1-1/4″ S/S| 510050| <—| <—| 2
34| C/S, 5/16-18×1″ S/S| 510048| <—| <—| 4
35| SMS, PanPhl #6 x 5/8″ Tapping| 510362| <—| <—| 2
36| Washer, 5/16 SAE S/S| 510107| <—| <—| 8
37| Seat Frame Assembly, complete| 330097| <—| <—| 1
38| Pin, leg adjustment assembly| 460445-08| <—| <—| 2
39| C/S, 114-20×1-3/4″ BtnSoc S/S| 510027| <—| <—| 4
40| Hole plug, 3/4″ black| 510263| <—| <—| 2
41| Backrest Frame Assembly| 330561-01| <—| <—| 1
42| Spacer, 1/41D x 3/40D Coved| 510261-01| <—| <—| 2
43| Spacer, 1/4ID x 3/40D x .250 thick| 510379| <—| <—| 2
Not Shown| Case, grey carrying, w/Handles| 410193| <—| <—| 1
Not Shown| Backrest Assembly, complete| 330815| 330562| 330816|
PARTS DIAGRAM
Aseptico Portable Pediatric Dental Chair
WARRANTY
Aseptico Inc. warrants its new products against defects in material and
workmanship under normal and proper use, care, and maintenance for a period of
two (2) years from date of original invoice. This two (2) year warranty does
NOT apply nor is it extended to products that are not manufactured by
Aseptico. These products may be covered by a separate limited warranty
provided by the particular manufacturer, and all claims and questions
regarding the same are to be directed to the particular manufacturer.
Expendable components, such as batteries, fuses, light bulbs, and tubing sets
installed on Aseptico products are specifically excluded and have no warranty.
Consumable goods are warranted for the stated expiration date of such goods.
Repair or replacement of any product(s) or part(s) under this warranty does
not extend the term of this warranty, and such product(s) or part(s) shall
remain covered by the unexpired portion of the warranty period, or for ninety
(90) days from the date of return to Aseptico, whichever is later. This
limited warranty applies only to the initial or first installation of the
product or part.
During the specific warranty periods set forth above, Aseptico will, at its
option, repair or replace the product(s) or particular part(s) that are found
to be defective in either material or workmanship in part or whole. Aseptico
shall be the sole arbiter of such action.
In the event of alleged defect under warranty, the purchaser is to notify
Aseptico’s Customer Service department promptly.
Customer Service will provide Return Material Authorization (RMA)
instructions, usually directing that the product be returned for service,
shipping prepaid by the buyer or end user, to Aseptico or its designated and
authorized warranty service center.
This warranty shall not apply to products (1) that have been subjected to
neglect, abuse, misuse, improper installation, inadequate maintenance, or
damage due to improper use of cleaning materials or chemicals, or non-
compliance with Aseptico’s storage, installation, operation, maintenance or
environmental requirements; (2) that have undergone any modification or repair
not previously authorized by Aseptico in writing, or service, repair or
modification by or from any facility other than an authorized Aseptico
service center or technician, or that use non-authorized software or spare or
replacement parts; or (3) that fail due to reasonable and normal use or wear
and tear, or materials made, furnished or specified by the buyer or end user.
Aseptico does not assume under this warranty any risks or liabilities arising
from the clinical use of its products, whether or not such use involves
coincidental utilization of products manufactured by others. Under no
circumstances will Aseptico be liable or responsible for special,
compensatory, incidental, consequential or punitive damages, lost profits,
lost sales, or loss of use or loss of business opportunity by or through the
use of the product. Aseptico’s sole and maximum liability with respect to the
product, other than its obligations set forth above, shall be the total
purchase price paid for the product.
P.O. Box 1548 • Woodinville, WA 98072-1548
1-800-426-5913 •
425-487-3157 • Fax:
360-668-8722
email: info@aseptico.com • Internet:
www.aseptico.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>