CAROMA Urbane ll Bidet Easy Height Wall Faced Close Coupled Toilet Suite Instruction Manual

June 12, 2024
Caroma

Urbane ll Bidet Close- Coupled 4.5/3 litre Cistern

Urbane ll Bidet Easy Height Wall Faced Close Coupled Toilet Suite


CAROMA Urbane ll Bidet Easy Height Wall Faced Close Coupled Toilet Suite -
Bottom

Note: Refer to Urbane II Bidet Cleanflush Wall Faced Close Coupled Pan installation instructions for water inlet connection details.CAROMA Urbane
ll Bidet Easy Height Wall Faced Close Coupled Toilet Suite -
fig

Note: The inlet valves are suitable for dynamic flow pressures of 30 kPa to 1000 kPa.
PLUMBERS’ INSTALLATION INSTRUCTIONS
PLEASE READ CAREFULLY BEFORE INSTALLATION REFER TO URBANE II BIDET CLOSE- COUPLED PAN INSTRUCTIONS FOR BOTTOM INLET SET-OUT

CISTERN FIXING PROCEDURE

Standard right hand bottom inlet (Internal overfiow only) installation The inlet valve can be changed from left to right or vice versa.
Note: The cistern flxes directly to the pan with a robust base fixing system without the need for wall fixing.

  1. Ensure the foam seal at base of cistern is securely attached to cistern base, as detailed in Fig. 2.
  2. Connect fiexible hose (for cistern) to inlet valve, as detailed in Fig. 2. Position cistern onto pan and align the cistern fixing holes with the threaded fixing holes located in the cistern platform.
  3. Fit the seals into the winged fixing bolts, as detailed in Fig. 1. Twist and remove main top section of outlet valve to access bottom of cistern.
  4. Insert the winged fixing bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 1.
  5. Flush the lines before connecting the fiexible hose to the stop tap.
  6. Adjusting water level: Turn on water mains. Open the cistern stop valve and check the operation of the mechanisms and valve. Adjust water level to the water level mark inside the cistern by simply turning the fioat arm adjustment screw in a clockwise or anti clockwise direction as detailed in Fig. 3.
  7. Fit cistern lid to check push button operation to complete installation.

IMPORTANT: THE STANDARD INLET VALVE IS FITTED WITH A LINE STRAINER. ITS TAIL IS CENTRALY LOCATED TO ALLOW EASY REMOVAL FOR CLEANING. THIS TAIL FITS EASILY INTO THE COPPER CONNECTION PIPE. INSTALLATION OF THE CISTERN WITHOUT THE STRAINER CAN LEAD TO DAMAGE OF THE INLET VALVE FROM THE WATER-BORNE CONTAMINANTS LEADING TO CISTERN MALFUNCTION.

Back Entry Installation

  1. Securely attach the self-adhesive foam seal around the outlet on the base of cistern, as detailed in Fig. 2. Remove inlet valve to gain access to the right hand cistern fixing hole.

  2.  Position cistern onto pan, and align the cistern fixing holes with the threaded fixing holes located in the cistern platform.

  3.  Ensure that the back inlet water connection nipple is aligned with the cut out in the back of the cistern. Fit the seals onto the winged fixing bolts.

  4.  Insert the winged fixing bolts through the cistern fixing holes into the threaded fixing holes located in the pan. Gradually tighten the left and right hand nuts by hand to firmly secure the cistern to pan, as detailed in Fig. 1.

  5.  Fit cistern stop valve (supplied) to the 1/2” B.S.P. nipple in the wall using approved thread seal, in the downward angled position as detailed in Fig. 4. Connect one end of fiexible hose to cistern stop valve.
    Note: Flexible hose assemblies shall not be submerged.

  6.  Refit the inlet valve into position.

  7. Flush the lines and ensure the hose is not rubbing against the inside of the cistern.

  8. Turn on water mains. Open cistern stop valve and check for leaks and operation of mechanisms and valves. Ensure there is no leakage from the cistern into the pan.

  9.  Adjust water level to the 4.5 litre water level mark inside the cistern by simply turning the fioat arm screw in a clockwise or anti-clockwise direction, as detailed in Fig. 4.

  10.  Fit cistern lid to check push button operation to complete installation.

IMPORTANT
TO ACHIEVE A SATISFACTORY 4.5/3L FLUSH PERFORMANCE AND A 4 STAR WATER EFFICIENCY  RATING THE CISTERN MUST BE MATCHED WITH A COMPATIBLE CAROMA SMARTFLUSH 4.5/3LTOILET PAN.
All measurements are subject to accepted manufacturing tolerances.
To ensure accuracy please check actual product dimensions before drilling for installation.
The manufacturer reserves the right to change specifications at any time without giving prior notification.
This product should be installed by a qualified plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements.

Issue No. 0
Date of Issue: 20.03.23

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Caroma User Manuals

Related Manuals