CAROMA 848605W Easy Height Wall Faced Back Inlet Toilet Pan Installation Guide

June 12, 2024
Caroma

**CAROMA 848605W Easy Height Wall Faced Back Inlet Toilet Pan Installation Guide

**

Assembly Instruction

Assembly Instruction
Assembly Instruction
Assembly Instruction
Assembly Instruction
Assembly Instruction Assembly
Instruction

Components shown in Fig. 3 are supplied with the 300071W Urbane II Electronic Bidet Seat.
Instruction

Before installation, make sure the water connection points and a Ø32mm conduit are in place to run the plug-in power cord connector through, as shown in Fig. 1 and Fig. 2.
Instruction

Note: The Urbane II Electronic Bidet Seat is supplied with 1.5m plug-in power cord with an IP65 rated connector.

ROUGHING IN

IMPORTANT: These operations must be performed by qualied service personnel.

Water Connection

  1. Mark centre line of the pan on the floor and stud frame, install the G½” (15mm projection from finished wall) connection in position as shown in Fig.1.
    Water Connection

Power Connection

  1. Install a wall plate or similar item for the power cable in a location close to the GPO (not included) within 1m linear length from the pan centre line. If a longer cable is required, the cable connector can be removed and assembled with a longer cable, as shown in Fig 2.
  2. Run a Ø32mm conduit parallel to the oor at 275mm high starting from the centre of the pan. Ø32mm swept elbows can be attached to the conduit at the other end if the GPO box is at a different height, as shown in Fig. 2.

Waste Connection

  1. The Urbane II Bidet Cleanush® back inlet pan is universal for both ‘S’ and ‘P’-Trap installations as detailed. The recommended set-out for ‘S’-Trap installations is 90mm from the nished wall with set-out exibility for existing soil pipe positions ranging from 60mm to 135mm and 50mm sideways adjustment with the Uni-Orbital® connector supplied, as shown in Fig. 4. Refer to installation instructions supplied with Uni-Orbital® connector.

Power Cable

  1. Feed the power cable from the connector end through the wall plate and conduit, and pull the cable through the hole in the wall above the Uni-Orbital® connector, as detailed in Fig. 5. Wire draw sh tape can be used to pull the cable through.
  2. Before proceeding ensure there is approx. 250mm of cable protruding from the wall.

INSTALLATION

Water Inlet Connection:

Fit the stop valve onto the threaded elbow while keeping the G½” end pointing upwards, as shown in Fig. 2. Apply thread tape on the stop valve thread.

  1. Fit the stop valve onto the threaded elbow while keeping the G½” end pointing upwards, as shown in Fig. 2. Apply thread tape on the stop valve thread.
  2. Install the dual check valve onto the stop valve. Place the washer inside the female end of ‘T’ tting then t it on the spigot of the check valve while ensuring the horizontal threaded end is facing forwards. Apply thread tape on both threaded spigots of the ‘T’ tting, as shown in Fig. 3.
  3. Fit the G½” end cap on the top spigot of ‘T’ tting.
  4. Screw the lter onto the front facing thread of ‘T’ tting and hand tighten, as shown in Fig. 3.
  5. Screw the G½” connection end of bidet hose to the male thread of lter, hand tighten and tighten further using a spanner. DO NOT OVERTIGHTEN AS IT MAY CRACK THE FILTER. Connect the bidet hose to the inlet of bidet seat, turn the mains ON and check for leakage. Disconnect the bidet seat before proceeding

‘S’- TRAP CONNECTOR FIXING PROCEDURE

  1. The centreline of the pan on wall and oor, as shown in Fig. 1 is to be used as a guide when connecting the pan. The centre line can be offset by up to 50mm from the soil pipe, as detailed in Fig. 4. Note: The water and power locations must be positioned relative to the pan centreline.

  2. Determine set-out “A” of existing pan connector, as detailed in Fig. 4. Set-out range 60mm – 135mm. Recommended set-out 90mm, as detailed in Fig. 4 and Fig. 6. For ‘P’ trap installation, see Fig. 7.
    For installation of the Uni-Orbital® connector, reference must be made to the instructions supplied with the connector.

  3. Prepare for pan xing method (bracket installation) as detailed below.

MPORTANT: Feed exible hose through the right hand side opening on pan before pushing pan onto Uni-Orbital® connector and wall, as detailed in Fig. 6 and Fig. 7.

Bracket Fixing:

  1. Position and push pan into Uni-Orbital® connector and ushpipe using the marked centre line on the wall as a guide to ensure that all ttings locate correctly. Remove the pan.

  2. Locate the D82 Concealed Fixing brackets (supplied) into position on centre line of pan 215mm from the nished wall and mark bracket xing hole centres on nished oor.

  3. Drill two holes in the marked positions on the oor. The hole diameter is dependent on the type of xing systemand oor nish.

  4. Secure Brackets to nished oor.

  5. Ensure that the area around the oor is clean and free from building material.

  6. Run a bead of acetic cured silicone sealant at a height of 8mm approximately fully around the foot of the pan which contacts the oor, leaving a 5mm gap in an inconspicuous position to detect for leaks. Use Wedges around the foot base (if required) so that the maximum height of silicone sealant is not greater that 5mm on completion.

  7. Ensuring the power cable is clear, carefully connect pan to connector and locate plastic xing sleeve into holes in the pan. Fit screw into the bracket and tighten to bed pan to oor while ensuring level, as detailed in Fig. 9.IMPORTANT: DO NOT OVER TIGHTEN, AS THIS MAY CRACK THE PAN FOOT. Snap on plastic cap, as detailed in Fig. 9.
    Instruction

  8. Provide support under the pan foot so that it is maintained in the levelled position while the silicone sealant sets. Remove any excess sealant to provide a neat joint between the pan and the oor. Allow at least 24 hours for the bedding sealant to set before use

IMPORTANT
TO ACHIEVE A SATISFACTORY 4.5/3L FLUSH PERFORMANCE AND A 4 STAR WATER EFFICIENCY RATING THE CISTERN MUST BE MATCHED WITH A COMPATIBLE CAROMA SMARTFLUSH 4.5/3L TOILET PAN

All measurements are subject to accepted manufacturing tolerances. To ensure accuracy please check actual product dimensions before drilling for installation. The manufacturer reserves the right to change specications at any time without giving prior notication. This product should be installed by a qualied plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals