Cube 0.8 litre Electronic Activation Urinal Suite User Manual
- June 8, 2024
- Caroma
Table of Contents
Cube 0.8 litre Electronic Activation Urinal Suite
Smart Demand ‘Urine Sensing’ Flushing System with Vitreous China Wall-Hung Box Rim Urinal
A contemporary design fully integrated box rim, wall mounted urinal operating with a ultra low flush of 0.8 litres to achieve a six star WELS rating. The system incorporates a fully automatic electronic smart demand ‘Urine Sensing’ urinal suite featuring hands free operation to give a combination of superior performance and optimum user hygiene, water saving and vandal resistance. Caroma Smartflush combines the new smart demand flushing system with the Cube 0.8 litre urinal ensuring optimal operational standards and efficiency. The sensor is concealed behind the urinal resulting in vandal resistant installation ideal for heavy-duty applications.
Inlet: Back inlet for concealed nominal 20mm dia. sparge pipe and
compression rubber fitting.
Outlet: The urinal trap is connected to wall waste pipe which allows for
a simple push on urinal connection.
Inwall: Automatic urinal flush system suitable for minimum cavity
thickness of 100mm.
Induct: Automatic urinal flush system.
Inceiling: Automatic urinal flush system.
Electronic Urinal Suite: Wall mounted urinal fit-out kit Code
No.678800; Rough-in kit Code No.678803
Fitting: Vitreous china grate supplied as standard. Vandal resistant
grate option Code No.687396.
Flush Control Mechanism: Smart demand ‘Urine Sensing’ operation with an
integrated smart logic system, detects user and determines flush mode
accordingly. The flush duration is adjustable to allow for the accurate
determination of flush volume at varying pressures.
Stadium operation: 5 or more uses with an interval of less than 60
seconds = 1 flush every 3 minutes. Automatically reverts to normal usage at
non peak periods.
Smartflush: Water Saving – Adaptive Flush Technology: The unit will
monitor usage and during normal usage frequency (less than once every 10
mins), the unit will flush after every use. If a higher usage frequency is
detected, the unit will flush once after the second use, after which the unit
will not flush again for a period of one hour or after 20 uses (whichever
comes first). The unit will then automatically revert to normal mode and
continue to monitor usage.
Hygienic Flush: Hygienic flush every 24 hours prevents the trap seal from
drying out.
Electronic Valve: The operating voltage of the valve is 6 volts DC. The
operation flow pressure of the valve is 300 to 500 kPa (30 to 50 metres head)
with a minimum flow to the valve of 18 litres / minute. The valve incorporates
an integral airbreak system and stop cock.
Electronics: Supply voltage to the system is 240V AC 50Hz. Operating
current 6 volts DC.
Installation: For general connection install a plug socket 240V AC
adjacent to the control box to local code requirements. Provide conduit
without kinks to connect the sensor cable to the control box. 3.5m of sensor
cable supplied as standard. Minimum supply diameter of nominal 20mm is
required to the valve. The urinal must be installed in accordance with the
AS/NZS 3500 Plumbing requirements. Local Authorities have varying
requirements.
Dimensions: All dimensions are in millimetres and are subject to normal
manufacturing variations. Caroma pursues policy of continued improvement in
design and performance of its products. The right is therefore reserved to
vary specifications without notice.
Dimensions
Installation
Cube Urinal Inlet and Outlet Detail
Setout Dimensions and Wall Waste Trap Fixing Detail
Cube 0.8 litre Electronic Activation Urinal Suite User Manual – Optimized
PDF
Cube 0.8 litre Electronic Activation Urinal Suite User Manual – Original
PDF
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>