CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan Installation Guide

June 12, 2024
Caroma

CAROMA Logo PLUMBERS INSTALLATION INSTRUCTIONS
For Vitreous China Urbane II Bidet Cleanfiush®
Easy Height Wall Faced Close Coupled Toilet Pan
PLEASE READ CAREFULLY BEFORE INSTALLATION

Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan

CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Power| CAROMA Urbane II
Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Position
---|---
CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Cistern| CAROMA
Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Bottom
CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Dimension| CAROMA
Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Components
CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Trap| CAROMA Urbane II
Bidet Easy Height Wall Faced Close Coupled Toilet Pan - Push
pan
CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Push pan| CAROMA Urbane II Bidet Easy Height Wall Faced Close Coupled Toilet Pan -
Cistern

Components shown in Fig. 3 and Fig. 4 are supplied with the 300071W Urbane II Electronic Bidet Seat.
Before installation, make sure the water connection points and a Ø32mm conduit are in place to run the plug-in power cord connector through, as shown in Fig. 1 and Fig. 2.
Note: The Urbane II Electronic Bidet Seat is supplied with 1.5m plug-in power cord with an IP65 rated connector.
ROUGHING IN:
IMPORTANT: These operations must be performed by qualified service personnel.
Water Connection

  1. Mark centre line of the pan on the fioor and stud frame, install the G½” (15mm projection from finished wall) connection in position as shown in Fig.1.

Power Connection

  1. Install a wall plate or similar item for the power cable in a location close to the GPO (not included) within 1m linear length from the pan centre line. If a longer cable is required, the cable connector can be removed and assembled with a longer cable, as shown in Fig 2.
  2. Run a Ø32mm conduit parallel to the fioor at 275mm high starting from the centre of the pan. Ø32mm swept elbows can be attached to the conduit at the other end if the GPO box is at a different height, as shown in Fig. 2.

Waste Connection

  1. The Urbane II Bidet Cleanfiush ® pan is universal for both ‘S’ and ‘P’-Trap installations as detailed. The recommended set-out for ‘S’-Trap installations is 140mm from the finished wall with set-out fiexibility for existing soil pipe positions ranging from 60mm to 245mm and 50mm sideways  adjustment with the Uni-Orbital® connector supplied, as shown in Fig. 5. Refer to installation instructions supplied with Uni-Orbital® connector.

Power Cable

  1. Feed the power cable from the connector end through the wall plate and conduit, and pull the cable through the hole in the wall above the Uni-Orbital® connector, as detailed in Fig. 6. Wire draw fish tape can be used to pull the cable through.
  2. Before proceeding ensure there is approx. 250mm of cable protruding from the wall.

INSTALLATION:

Water Inlet Connection

  1. Fit the stop valve onto the threaded elbow while keeping the G½” end pointing upwards, as shown in Fig. 2. Apply thread tape on the stop valve thread.
  2. Install the dual check valve onto the stop valve. Place the washer inside the female end of ‘T’ fitting then fit it on the spigot of the check valve while ensuring the horizontal threaded end is facing forwards. Apply thread tape on both threaded spigots of the ‘T’ fitting, as shown in Fig. 3.
  3. Fit the G½” end cap on the top spigot of ‘T’ fitting. Note: For Bottom Inlet cistern connection, G½” end cap is not required. 450mm G½’’ to G½” elbow hose (not supplied) must be fitted to the vertical threaded end of ‘T’ fitting.
  4.  Screw the filter onto the front facing thread of ‘T’ fitting and hand tighten, as shown in Fig. 3.
  5.  Screw the G½” connection end of bidet hose to the male  thread of filter, hand tighten and tighten further using a spanner. DO NOT OVERTIGHTEN AS IT MAY CRACK THE FILTER. Connect the bidet hose to the inlet of bidet seat, turn the mains ON and check for leakage.
    Disconnect the bidet seat before proceeding.

‘S’- TRAP CONNECTOR FIXING PROCEDURE

  1. The centreline of the pan on wall and fioor, as shown in Fig. 1 is to be used as a guide when connecting the pan. The centre line can be offset by up to 50mm from the soil pipe, as detailed in Fig. 5.
    Note: The water and power locations must be positioned  relative to the pan centreline.

  2. Determine set-out “A” of existing pan connector, as detailed in Fig. 5. Set-out range 60mm – 245mm. Recommended set-out 140mm, as detailed in Fig. 5 and Fig. 7. For ‘P’ trap installation, see Fig. 8.

  3. For installation of the Uni-Orbital® connector, reference must be made to the instructions supplied with the connector.

  4. Prepare for pan fixing method (bracket installation) as detailed below.
    IMPORTANT: Feed the G1/2” to G1/2” fiexible hose through the right hand side bottom inlet hole and the 3/8” fiexible hose (for bidet seat) through the right  hand side opening on the pan before pushing pan onto Uni-Orbital ® connector against the  wall, as shown in Fig. 7 & Fig. 8.

Bracket Fixing:

  1. Position and push pan into Uni-Orbital® connector using the marked centre line on the wall as a guide to ensure that all fittings locate correctly. Remove the pan.

  2. Locate the D82 Concealed Fixing brackets (supplied) into position on centre line of pan 300mm from the finished wall and mark bracket fixing hole centres on finished fioor.

  3. Drill two holes in the marked positions on the fioor. The  hole diameter is dependent on the type of fixing systemand fioor finish.

  4.  Secure Brackets to finished fioor.

  5.  Ensure that the area around the fioor is clean and free  from building material.

  6. Run a bead of acetic cured silicone sealant at a height of 8mm approximately fully around the foot of the pan which contacts the fioor, leaving a 5mm gap in an inconspicuous position to detect for leaks. Use Wedges around the foot base (if required) so that the maximum height of silicone sealant is not greater that 5mm on completion.

  7.  Ensuring the power cable is clear, carefully connect pan to  connector and locate plastic fixing sleeve into holes in thepan. Fit screw into the bracket and tighten to bed pan to fioor while ensuring level, as detailed in Fig. 10.
    IMPORTANT: DO NOT OVER TIGHTEN, AS THIS MAY CRACK THE PAN FOOT. Snap on plastic cap, as detailed in Fig. 10.

  8. Provide support under the pan foot so that it is maintained in the levelled position while the silicone sealant sets. Remove any excess sealant to provide a neat joint between the pan and the fioor. Allow at least 24 hours for the bedding sealant to set before use.

IMPORTANT TO ACHIEVE A SATISFACTORY 4.5/3L FLUSH PERFORMANCE AND A 4 STAR WATER EFFICIENCY RATING THE CISTERN MUST BE MATCHED WITH A COMPATIBLE CAROMA SMARTFLUSH 4.5/3L TOILET PAN.
All measurements are subject to accepted manufacturing tolerances.
To ensure accuracy please check actual product dimensions before drilling for installation.
The manufacturer reserves the right to change specifications at any time without giving prior notification.
This product should be installed by a qualified plumber. Local authority, Water Board, and Building Regulations may apply to the installation of this product, and you should consult the appropriate bodies on these requirements.
Issue No: 0
Date of Issue: 24/03/23CAROMA Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Caroma User Manuals

Related Manuals