41002 – 41005
Dimensional data
- Recommended height, unless different regulations are specified.
- Installation should be carried out by qualified personnel in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
Installation
Front view
1 – LED for the light signals described below in the “Indicators” section
2 – Mini USB connector for configuration via PC and specific software.
3 – Call buttons
4 – Loudspeaker
5 – Microphone| 6 – LED lighting shooting area
7 – Camera
Angle opening to 1 m
H 104 ° (2.6 m) ; V 83 ° (1.8 m); diagonal 129 °
---|---
- Indicators: at the top right of the speech units there are three LEDs with the following meanings starting from top to bottom:
| • Green LED: on -> communication indicator on; blinking -> call in progress
indicator (0.5 sec on, 0.5 sec off, cycle 1 s)
---|---
| • Green LED on -> lock activation
| • Red LED: on -> signalling Bus busy – blinking -> signalling lost
communication
Rear view
-
CCTV type external camera connection terminals
M = ground ; V = coaxial cable -
Connector for wiring to additional electronic modules (via harness)
-
Removable wiring terminal block
S+ / S – Electric lock output
CA + / CA – Lock control additional button (Default).
Alternatively (if configured via SaveProg), sensor input to signal “Door Open”.
E + / E – Additional external power supply, from power supply unit 6923
B1 / B2 Due Fili Bus Plus
Note: S+/S- outputs. The entrance panel supplies a current peak IT > 1 A for 10 ms after which there follows a holding current IM = 200 mA for the entire duration of the lock command (see lock time).
- Tele loop and control speech synthesis function. Modules 41002 and 41005 are ideal for people who are physically challenged, wear a hearing aid or are partially sighted. Enable the hearing aid, referring to its instruction manual.
Note: any metal objects or electronic equipment nearby may compromise the quality of the sound received by the hearing aid.
Control speech synthesis is enabled with Save Prog.
First power up
- Configuration combined with push button module 41010
- Press and hold down button 1 for more than 5 seconds until you hear a continuous tone
- Release
- Enter the PIN code (default 1234)
- Press button 4; the LED on button 1 lights up permanently
- Press one button on each module 41010, in the desired order. Once a button of the last 41010 has been pressed, the procedure ends automatically.
| LED on
---|---
| LED flashing
| LED off
beep| High tone
BEEP| Low tone
Wiring diagrams
• Wiring diagram of Due fili Plus electronic unit| • Wiring diagram of Due
fili Plus electronic unit
---|---
|
System supply unit
-
Connection variant for electronic unit 41002 with external CCTV camera
• Power supply unit for external CCTV camera -
The camera must be equipped with its own power supply unit with suitable characteristics. Check that the type of power supply unit and the connections do not cause any interference with the operation of the electronic unit. The video input of art. 41002 has an internal termination in AC at 75 Ω for CVBS signals of typically 1 Vpp. Should the camera also require a termination in DC to enable the transmission of the video signal, a resistor needs to be connected externally with a value that will not significantly alter the impedance in AC.
Technical data
- Power supply from Due Fili Plus Bus, via terminals B1 and B2: 28 VDC rated.
Minimum voltage on terminals B1 and B2: 21VDC
Local power via terminals E+, E- if the electronic unit needs to be powered via an additional power supply unit. The additional power supply unit should be installed if the system’s maximum consumption exceeds the power supply unit’s capacity.
Absorption from Bus or from additional power supply unit:| 41002| 41005
---|---|---
on Stand by
in communication
lock activation
maximum additional modules
maximum| 40 mA
130 mA
+ 50 mA
+ 130 mA
310 mA| 40 mA
200 mA
+ 50 mA
+ 130 mA
390 mA
The maximum current delivered to the additional electronic modules (back
panel) is 500mA (maximum 8 additional modules). Refer to the additional
modules for sizing the load on the back panel and on the bus.
Operating temperature: (- 25) – (+ 55) °C.
Video output signal 16 dBm
Protection class IP 54
Protection rating against impact: IK 08 (Pixel), IK 10 (Pixel Heavy)
- Regulatory compliance. EMC directive. EN60065, EN 61000-6-1, EN61000-6-3 and EN60118-4 standards. REACH (EU) Regulation no. 1907/2006 – art.33. The product may contain traces of lead. (*)
• WEEE – Information for users. If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other general waste at the end of its working life. The user must take the worn product to a sorted waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m2, if they measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health, and encourages the re-use and/or recycling of the construction materials.
• For further information and details on all the functions, download the manual herein and the Use and Configuration manual from the www.wimar.com website. (*)
Viale Vicenza, 14
36063 Marostica VI – Italy
www.vimar.com
49401265D0 00 2203
References
- wimar.com - This website is for sale! - wimar Resources and Information.
- Home automation, electrical equipment, smart home - Vimar energia positiva
- wimar.com - This website is for sale! - wimar Resources and Information.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>