Preface

Read this user manual carefully before using the product. Pictures are shown in this manual for reference only. Different models and specifications are subject to real products.
This manual is only for operation instruction, please contact the local distributor for maintenance assistance. The functions described in this version were updated till March 2018. In the constant effort to improve the product, we reserve the right to make functions or parameter changes without notice or obligation. Please refer to the dealers for the latest details.

Trademarks

The product model, PTN and its logo are trademarks of PTN Electronics Limited. Any other trademarks mentioned in this manual are acknowledged as the properties of the trademark owner. No part of this publication may be copied or reproduced without the prior written consent of PTN Electronics Limited.

FCC Statement

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. It has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation.
Operation of this equipment in a residential area is likely to cause interference, in which case the user at their own expense will be required to take whatever measures may be necessary to correct the interference.
Any changes or modifications not expressly approved by the manufacturer would void the user’s authority to operate the equipment.

SAFETY PRECAUTIONS

To ensure the best from the product, please read all instructions carefully before using the device. Save this manual for further reference.

  • Unpack the equipment carefully and save the original box and packing material for possible future shipment
  • Follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
  • Do not dismantle the housing or modify the module. It may result in electrical shock or burn.
  • Using supplies or parts not meeting the products’ specifications may cause damage, deterioration or malfunction.
  • Refer all servicing to qualified service personnel.
  • To prevent fire or shock hazards, do not expose the unit to rain, or moisture or install this product near water.
  • Do not put any heavy items on the extension cable in case of extrusion.
  • Do not remove the housing of the device as opening or removing the housing may expose you to dangerous voltage or other hazards.
  • Install the device in a place with fine ventilation to avoid damage caused by overheat.
  • Keep the module away from liquids.
  • Spillage into the housing may result in fire, electrical shock, or equipment damage. If an object or liquid falls or spills on to the housing, unplug the module immediately.
  • Do not twist or pull by force ends of the optical cable. It can cause malfunction.
  • Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the device before cleaning.
  • Unplug the power cord when left unused for a long period of time.
  • Information on disposal for scrapped devices: do not burn or mix with general household waste, please treat them as normal electrical wastes.

IMPORTANT SAFETY INSTRUCTIONS

  1. Read these instructions – All the safety and operating instructions should be read before this product is operated.

  2. Keep these instructions – The safety and operating instructions should be retained for future reference.

  3. Heed all warnings – All warnings on the appliance and in the operating instructions should be adhered to.

  4. Follow all instructions – All operating and use instructions should be followed.

  5. Do not use this apparatus near water – The appliance should not be used near water or moisture – for example, in a wet basement or near a swimming pool, and the like.

  6. Clean only with dry cloth.

  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

  9. Do not defeat the safety purpose of the polarized or grounding plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet.

  10. Protect the power cord from being walked on or pinched particularly at the plugs, convenience receptacles, and at the point where they exit from the apparatus.

  11. Only use attachments/accessories specified by the manufacturer.

  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart or rack is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

  13. Unplug the apparatus during lightning storms or when unused for long periods of time.

  14. Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

  15. CAUTION : These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

  16. Caution – To prevent electric shock hazards, replace the grille.

  17. Do not install this equipment in a confined or building-in space such as a bookcase or similar unit, and remain a good ventilation condition at open site. The ventilation should not be impeded by covering the ventilation openings with items such as newspaper, tablecloths, curtains etc.

  18. WARNING : Only use attachments/accessories specified or provided by the manufacturer (such as the exclusive supply adapter, battery etc).

  19. WARNING : Please refer the information on exterior bottom enclosure for electrical and safety information before installing or operating the apparatus.

  20. WARNING : To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture. The apparatus shall not be exposed to dripping or splashing and that objects filled with liquids, such as vases, shall not be placed on the apparatus.

  21. WARNING : For the terminals marked with the symbol of “ ” may be of sufficient magnitude to constitute a risk of electric shock. The external wiring connected to the terminals requires installation by an instructed person or the used of ready-made leads or cords.

  22. CAUTION : Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type.

  23. WARNING : To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation instruction.

  24. WARNING: The battery (battery or battery or battery pack) shall not be exposed to excessive heat such as sunshine, fire or the like.

  25. WARNING: Excessive sound pressure from earphones and headphones can cause hearing loss.|
    WARNING : Listening to music at high volume levels and for extended durations can damage one’s hearing. In order to reduce the risk of damage to hearing, one should lower the volume to a safe, comfortable level, and reduce the amount of time listening at high levels. Headsets should comply with EN 50332-2 requirements (for GS certification).

  26. WARNING : The mains plug/appliance coupler/direct plug-in adapter is used as a disconnect device, the disconnect device shall remain readily operable. or
    The all-pole mains switch located on front panel is used as the disconnect device, the switch shall remain readily operable. or
    The all-pole mains switch and all-pole circuit breaker are not provided with the apparatus, the installation shall be carried out in accordance with all applicable installation rules. Or

  27. This lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of non-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock.

  28. Warning : To reduce the risk of electric shock, do not remove cover (or back) as there are no user-serviceable parts inside. Refer servicing to qualified personnel.

  29. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance.PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig- \(1\)

  30. Protective earthing terminal. The apparatus should be connected to a mains socket outlet with a protective earthing connection.

  31. Caution – To prevent electric shock hazards, replace grille. (CSA 60065, clause 5.3A)

Product Introduction

The product is an integrated switching power supply designed for converting AC into DC power. It provides 2 input channels and 12 output channels, input voltage 100~240VAC, output 5/12/24VDC, the max power consumption of a single channel is 15W. Base on the sequential control technology, when powered on, the 12 output channels will turn on orderly every 100ms.In addition, each output channel also can be switched on/off via front panel button, RS232 commands or GUI, and the output voltage on each output channel can be selected as 5/12/24V DC via the TACT Switch on rear panel, RS232 command, or GUI.

Features

  • Double input channel designed for ensuring a stable AC source.
  • Total 12 output channels and each channel has three kinds of output voltage (5/12/24VDC) can be selected.
  • Output channels can be switched on/off by via the front panel buttons, RS232 commands or GUI.
  • Output voltage (5/12/24VDC) can be selected via the TACT Switch on rear panel, RS232 commands, or GUI.
  • Adopt sequential control technology.
  • Supports online software upgrading.

Package List

  • 1 x TPUH-PSU12-UL
  • 2 x Mounting Ears & 6 x Screws
  • 4 x Plastic Cushions
  • 2 x Power Cords
  • 12 x DC Power Cables (2-pin Phoenix Connector to DC)
  • 12 x 2-pin Phoenix Connectors
  • 1 x 3-pin Phoenix Connector
  • 1 x RS232 Cable (DB9 to 3-pin Phoenix Connector)
  • 1 x User Manual

Note : Please contact your distributor immediately if any damage or defect in the components is found.

Specification

Input & Output

Input Port| AC1 & AC2
Input Voltage| 100~240VAC 50~60Hz
Output Port| Total 12 DC port (2-Pin phoenix connectors)
Output Voltage| 5V, 12V or 24V can be selectable.


Output Voltage Range

| 5V: 4.75~5.25V
12V: 11.4~12.6V
24V: 22.8~25.2V
Maximum output power consumption of signal channel| 5V:12W; 12V:15W; 24V:15W
Maximum output power consumption for single supply| 180W
Maximum output power consumption for dual supply| 180W
Control Part


Buttons Control

| Front Panel: 01~12, total 12 buttons.
Rear Panel: Total 12 TACT Switches, named

SELECT.


RS232 Control

| RS232 port (3-Pin phoenix connector).
Baud rate support 9600.


GUI Control

| TCP/IP port (RJ45)
Default IP: 192.168.0.178
Port No.: 4001
General
Temperature| 0 ~ +50℃
Humidity| 10% ~ 90%
Dimension (WHD)| 437mm x 44mm x 357mm
Net Weight| 4.2Kg

Panel Description

Front Panel
PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(4\)

No. Name Description
FIRMWARE USB port for updating system firmware.



| ****


AC1 & AC2

| Input AC source indicators.

l  Green when the device is powered on and normal output.

l  Red when there is no power to the device.

l  Orange when the input voltage is too low or too high.





| ****




01~12

| Output channel switching buttons and Activity LEDs, 12 in total.

l  Press the button to trun on/off the corresponding channel,and the corresponding LED will turn green and keep on.

l  Long-press the button for 3 seconds or more to lock/unlock the corresponding channel, and then the corresponding LED will flash 3 times.

Note : Pictures shown in this manual are for reference only, different model and specifications are subject to real product.

Rear PanelPTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(5\)

No. Name Description








| ****








01~12

| 12 output channals.

A. DC: 2-Pin phoenix connector, connect with the device needed to be powered.

B. SELECT: Press the TACT Switch to select the output voltage among 5V, 12V, and 24VDC. In addition, simultaneously long-press this buttons on channel 01 and channel 02 for 3 seconds or more, the device will be restored to factory setting.

C. 5/12/24V indicators:

l  Green when the current selected output voltage is work normally.

l  Blinking slowly when the current channel is closed.

l  Blinking fastly when the current channel is short circuit or over voltage.


| ****

RS232

| Serial port, 3-Pin phoenix connector, connect with a control device (such as PC) to control the product via RS232 commands.
③| TCP/IP| Ethernet port, connect with PC to control the product via GUI.
④| AC1& AC2| 2 AC input channels. Input voltage is AC100~240V.

Note : Pictures shown in this manual are for reference only, different model and specifications are subject to real product

System Connection

Usage Precaution

  • Verify all components and accessories included before installation.
  • Make sure all components and accessories included before installation.
  • System should be installed in a clean environment with proper temperature and humidity.
  • All of the power switches, plugs, sockets, and power cords should be insulated and safe.
  • All devices should be connected before power on.

System DiagramPTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(6\)

System Operation

Button Control

  • Switch on/off output channel:
    Press the button 01~12 on front panel to switch on/off the corresponding output channel.

  • Lock/unlock output channel:
    Long-press the button 01~12 for 3 seconds or more on front panel to lock/unlock the corresponding channel, and then the corresponding LED will flash 3 times.
    Note : The locked channel can’t be controlled via front panel button、RS232 commands and GUI.

  • Select the output voltage:
    Press SELECT on the corresponding output channel to select the output voltage as 5V, 12V or 24V.
    Note : After switching the output voltage, the output channel will be turned off based on overvoltage protection control, and it need to be turned on again via the corresponding output channel switching button on front panel

  • Restore Factory Defaults:
    On the rear panel, simultaneously long-press SELECT on channel 01 and channel 02 for 3 seconds or more, the device will be restored to factory setting

RS232 Control

Connect a PC to the RS232 port on the rear panel, and then install the RS232 control software on the PC, the product can be controlled by sending RS232 commands via the RS232 control software.

RS232 Control Software

  • Installation Copy the control software file to the computer connected with the product.
  • Uninstallation Delete all the control software files in corresponding file path.

Basic Setting

Double-click the software icon to run this software.
Here we take the software CommWatch.exe as example. The icon is showed as below: ****

The interface of the control software is showed as below:PTN-TPUH-PSU12-UL-
Integrated-Switching-Power-Supply-fig- \(8\)

Please set the parameters of COM number, bound rate, data bit, stop bit and the parity bit correctly, and then you are able to send command in Command Sending Area.

RS232 Communication Command

Command Function Feedback Example
All@. Switch on all output channels. All Open.
All$. Switch off all output channels. All Closed.

[x]@.

| Switch on the output channel [x],

x =1~12.

|   [x] Open.

[x]$.

| Switch off the output channel [x],

x =1~12.

|   [x] Closed.

Output/[x]V/[y].

| When y = NULL, Set the output voltage as x for all output channels.

x =5/12/24.

|

All Output [x]V.

When y =1~12, Set the output voltage as X for the output channel y.

x =5/12/24.

|   [y] Output [x]V.

Status[x].

|

When x = NULL, query the on-off status of all output channels.

| 01    Open.

02    Closed.

03    Closed.

When x = 1~12, query the on-off status of the output channel x.| [x] Open.
[x] Closed.
Save[x].| Save the current on-off status to Group x. x =1~5.| Save To F[x].

Recall[x].

|

Invoke the on-off status of Group x. x =1~5.

| If Group x has no data, the feedback information:

F[x] no data.

Command Function Feedback Example
    If Group x has data, the                       feedback information:

Recall From F[x].

Out  01 02 03 04 05

06 07 08 09 10 11 12

State S S S S S S S S S S S S

Vm 12 12 12 12 12 12

12 12 12 12 12 12

Over N N N N N N N N N N N N

Lock N N N N N N N N N N N N

Clear[x].

| When x =NULL, clear the data of all Group.| Clear All.
When x =1~5, clear the data of the Group x.| Clear F[x].

QueryGroup[x].

|

When x = NULL, query all groups.

| Out  01 02 03 04 05

06 07 08 09 10 11 12

Vm1  12 12 12 12 12

12 12 12 12 12 12 12

Vm2 XX XX XX XX XX XX XX XX XX XX XX XX

……

When x = 1~5, query the group x.

| Out  01 02 03 04 05

06 07 08 09 10 11 12

Vm[x]  12 12 12 12

12 12 12 12 12 12 12

12

%0911.| Restore Factory Defaults.| Factory Default
%9964.| Query the IP address.| IP XXX.XXX.X.XXX
Command| Function| Feedback Example
---|---|---

ChangeIP XXX.XXX.X.XXX

| Change IP address/Subnet Mask/Gateway, For example: ChangeIP 192.168.0.178/255.255.255.0/0.0.0.0;|

%9975.

|

Query the all status for all channels.

| Out        01 02 03 04

05 06 07 08 09 10 11

12

State S S S S S S S S S S S S

Vm          12 12 12 12

12 12 12 12 12 12 12

12

Over N N N N N N N N N N N N

Lock N N N N N N N N N N N N

/^Version;| Query the software version.| V x. x. x

Lock[x].

| When x = NULL, lock all channels.| Locking all channel.
When x = 1~12, lock the channel x.| Locking [x] channel.

Unlock[x].

| When x = NULL, unlock all channels.| Locking all channel.
When x = 1~12, unlock the channel x.| Locking [x] channel.

LockKeyboard[x].

| When x=0, unlock the front panel.| Unlocking keyboard.
When x=1, lock the front panel.| Locking keyboard.

FA XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX FE

| Modify product name.

The command has 18 bytes in total, and 16 bytes are effective. The digit 0 is used for padding.

For example: FA 50 54 4E 00 00 00

00 00 00 00 00 00 00 00 00 00

FE(PTN)

|
FB XX XX XX XX XX XX XX XX XX| Modify product model.|
Command| Function| Feedback Example
---|---|---
XX XX XX XX XX XX XX FE| The command has 18 bytes in total, and 16 bytes are effective. The digit 0 is used for padding.

For example: FB 54 50 55 48 2D 50

53 55 31 32 00 00 00 20 00 00

FE(TPUH-PSU12-UL)

|

Rebootx.

| When x=NULL, reboot all output ports; When x=1~12, reboot the output port x.|

Rebootx.

Communication protocol: RS232 Communication Protocol

Baud rate : 9600

Note:

  • After sending the “Output/[x]V/[y].” to change the output voltage, the corresponding output channel will be switch off, the command “[x]@.” should be sent to switch on this output channel again.
  • After sending the “LockKeyboard[x].” to lock the front panel, the device can be controlled via RS232 commands and GUI.

GUI Control

In addition to control the product via front panel button and RS232 communication software. This product can be controlled via GUI. It allows users to interact with the product through graphical icons and visual indicators.

  1. Connect a PC to the TCP/IP port on the rear panel, and set its network segment to the same as the default IP of the product (192.168.0.178, port No.: 4001).PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig- \(9\)
  2. Type 192.168.0.178 in your browser, it will enter the log-in interface shown as below:PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig- \(10\)

Control Menu

Type user name: user and password: user (default setting) on the log-in interface, and then click Login to enter Control menu shown as below:PTN-
TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(11\)

  • Select the ON/OFF to switch on/off the output channel.
  • Click the All On to switch on all output channels.
  • Click the All Off to switch off all output channels

Voltage Setting Menu

Click Voltage Setting on the top of page to enter voltage setting menu shown as below:PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(12\)

  • Lock/Unlock the output channel. When the port is locked, its voltage cannot be switched.
  • Select 5V, 12V, or 24V output voltage for each output channel.

Network Menu
Click Network on the top of page to enter network setting menu shown as below :PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(13\)

  • Dynamic or static IP mode can be selected. Under static IP mode, IP address and subnet mask, gateway can be set and make sure the IP addresses are different to avoid IP conflict.

Password Menu
Click Password on the top of page to enter the password menu shown as below :PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(14\)

  • Modify the password as you need.
  • Lock/Unlock front panel buttons.

GUI Update

GUI for the Scaler Switcher supports online update in http://192.168.0.178:100. Type the username and password (the same as the GUI log-in settings, modified password will be available only after rebooting) to log in the configuration interface. After that, click Administration at the source menu to get to Upload Program as shown below:PTN-TPUH-PSU12-UL-
Integrated-Switching-Power-Supply-fig- \(15\)

Panel Drawing

PTN-TPUH-PSU12-UL-Integrated-Switching-Power-Supply-fig-
\(16\)

Troubleshooting & Maintenance

Problems Potential Causes Solutions




No output voltage

| Power supply protect function will start when over loaded.| ****

Please reduce loads.

After selecting output voltage, the output channel

will switch off automatically.

| Switch on the output channel via front panel

button.


Fail or loose connection

| Make sure the connection is good.
AC1 or AC2 indicator doesn’t work or no respond to any

operation

| ****

Fail connection of power cord.

| ****

Make sure the power cord connection is good.



Cannot control the device by control device (e.g. a PC) through RS232 port

| ****

Wrong RS232 communication parameters

| Type in correct RS232

communication parameters.


Fail or loose connection

| Make sure the connection is good.


Broken RS232 port

| Send it to authorized dealer for checking.
Cannot control the device by front panel buttons while can control it through

RS232 port

| ****


The front panel buttons are broken

| ****


Send it to authorized dealer for repairing.






Cannot control the device via GUI

| The IP address of control PC and TCP/IP port are not on the same network

segment

| Modify control PC’s network segment to the same with the TCP/IP

port.

---|---|---


The port No. are wrong.

| The correct port No. is 4001.


Fail or loose connection

| Make sure the connection is good.


Broken TCP/IP port

| Send it to authorized dealer for checking.

Note : If your problem still remaining after following the above troubleshooting steps, please contact your local dealer or distributor for further assistance.

Customer Service

The return of a product to our Customer Service implies the full agreement of the terms and conditions hereinafter. There terms and conditions may be changed without prior notice.

  1. Warranty
    The limited warranty period of the product is fixed three years.

  2. Scope
    These terms and conditions of Customer Service apply to the customer service provided for the products or any other items sold by authorized distributor only.

  3. Warranty Exclusions:

  4. Warranty expiration.

  5. Factory applied serial number has been altered or removed from the product.

  6. Damage, deterioration or malfunction caused by:

  7. Normal wear and tear.

  8. Use of supplies or parts not meeting our specifications.

  9. No certificate or invoice as the proof of warranty.

  10. The product model showed on the warranty card does not match with the model of the product for repairing or had been altered.

  11. Damage caused by force majeure.

  12. Servicing not authorized by distributor.

  13. Any other causes which does not relate to a product defect.

  14. Shipping fees, installation or labor charges for installation or setup of the product.

  15. Documentation :
    Customer Service will accept defective product(s) in the scope of warranty coverage at the sole condition that the defeat has been clearly defined, and upon reception of the documents or copy of invoice, indicating the date of purchase, the type of product, the serial number, and the name of distributor.

Remarks : For further assistance or solutions, please contact your local distributor (info@ptn-electronics.de).
www.PTN-Electronics.de

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals