BROAN NuTone Overture Hardwired Room Sensor User Guide
- June 12, 2024
- Broan
Table of Contents
BROAN NuTone Overture Hardwired Room Sensor
OvertureTM HARDWIRED ROOM SENSOR
The OvertureTM Hardwired Room Sensor is a smart control device that is designed to work with the OvertureTM system. It allows you to monitor and control various aspects of your home environment.
INCLUDED
- Hardwired Room Sensor Part No. 1110725
- User Manual
- Quick Start Guide
- Wire Nuts: Quantity 3
CONTROL SPECIFICATIONS
The OvertureTM Hardwired Room Sensor requires a 120 VAC power source (hot and
neutral) in the switch box to operate.
SAFETY
To ensure safety and prevent any risks of fire, electric shock, or injury to
persons, please observe the following precautions:
- Before installing the Hardwired Room Sensor, turn off the power and lockout the service panel.
INSTALLATION
Follow these steps for proper installation of the OvertureTM Hardwired Room
Sensor:
- Location Notes:
- The control should be placed on interior walls only at switchbox height from the floor.
- Avoid placing the control near HVAC equipment such as heat registers, cold air returns, heaters, fans, and drafts.
- Ensure that the Hardwired Room Sensor is within the range of your Wi-Fi router or access point (approximately 100 feet).
- Avoid physical obstructions and radio interference in the surrounding area.
- Install the control in at least a 3 deep dual-gang junction box. It can be installed in either a metal outlet box or a plastic outlet box.
- Attach the incoming power line to the switch box, using proper connectors. Provide 6 leads inside the box if necessary.
- Make electrical connections following the wiring diagram provided or refer to the Broan-NuTone OvertureTM website. Use wire nuts and ensure proper grounding.
- Tuck the wires in and fasten the control to the junction box using the attached screws. Verify the orientation of the Hardwired Room Sensor before installation (UP direction shown on the front of the control).
- Attach the front cover by aligning the top locators and snaps on the bottom. Push to secure.
- Download the Broan-NuTone OvertureTM App for step-by-step set-up instructions to connect your Hardwired Room Sensor to the OvertureTM system. Scan the QR code to go to the App Store.
For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: In the United States – Broan- NuTone.com 800-558-1711. In Canada – Broan-NuTone.ca 800-567-3855
BIAQHWRS100 Wiring Diagram
Power Supplied to Switch Box
120 VAC LINE IN
Switch Box
BLK WHT GND
1110078A
INCLUDED
- Hardwired Room Sensor Part No. 1110725
- User Manual
- Quick Start Guide
- Wire Nuts: Quantity 3
CONTROL SPECIFICATIONS
- cULus Listed
- 120 VAC 60 Hz Line Power
- Typical Wire Sizes: 12 AWG (MAX) or 14 AWG solid wire rated for at least 90°C
- Operating temperature: 32-95°F (0-35°C)
- Purpose of Control: Operating Control
- Rated impulse voltage: 2500 V
SAFETY
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
- Before installing the Hardwired Room Sensor, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. CAUTION: Risk of Electric Shock – More than one disconnect switch may be required to de-energize the equipment before servicing.
- All electrical work must be done in accordance with local codes, ordinances, or National Electrical Code, as applicable, including fire-rated construction codes and standards. FOR SAFETY, THIS PRODUCT MUST BE GROUNDED. If you are unfamiliar with methods of installing electrical wiring, secure the services of a qualified electrician.
- Use copper wire only.
- Install only in a UL Listed dual-gang junction box sized 4.0 x 3.0 x 3.0 in. (101.6 x 76.2 x 76.2 mm) or larger, with a minimum volume of 30.0 in³ (491.6 cm³) and a minimum depth of 3.0 in (76.2 cm).
- This control requires a neutral wire for operation.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.
- To prevent serious injury from electrical shock or damage to electrical components – DO NOT WIRE HOT!
- The automatic operation feature is Type 1 action, according to UL 60730-1.
- The enclosure protection rating is IP10.
- The product is Pollution Degree 2, which is intended to be used in a household environment or similar.
- The devices are not intended for use in locations where the temperature may be less than actual room conditions, such as unheated warehouses or garages.
- Avoid water and wet locations. Keep the device away from water, fire, excessive humidity, or hot environments.
- Do not use the device where wireless devices are not allowed.
- Do not attempt to disassemble, repair, or modify the device. Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us.
- Note: When power is applied, the Hardwired Room Sensor 1110725 may require approximately 30 seconds to boot up and be ready to function.
- Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your own risk.
Warranty is void if miswired.
INSTALLATION
NOTE: This control requires a 120 VAC source (hot and neutral) in the switch box to operate the Hardwired Room Sensor.
-
Turn off the power and lockout the service panel before wiring the control.
-
Location
Notes :- The control should be placed on interior walls only at switch box height from the floor.
- Keep the control away from HVAC equipment such as heat registers, cold air returns, heaters, fans, and drafts.
- Place your Hardwired Room Sensor within the range of your Wi-Fi router or access point (approximately 100 feet).
- Avoid physical obstructions and radio interference in the surrounding area.
-
Install the control in at least a 3″ deep dual-gang junction box. The control can be installed in either a metal outlet box or a plastic outlet box.
Attach the incoming power line to switch box. It may be necessary to use two side knockouts for some applications. Use proper connectors. Provide 6″ leads inside box. -
Make electrical connections following the diagram below or on the Broan-NuTone OvertureTM website. Use wire nuts. Make sure the control is properly grounded.
-
Tuck wires in and fasten control to junction box using attached screws. Verify Hardwired Room Sensor orientation before installation. Note “UP” direction shown on the front of control.
-
Attach front cover by aligning top locators and snaps on the bottom. Push to secure.
-
Download the Broan-NuTone OvertureTM App for step by step set-up instructions to connect your Hardwired Room Sensor to the OvertureTM system. Scan QR code to go to App Store.
For Warranty Statement, Service Parts, Technical Support, or to Register your product, please visit our website or call: In the United States – Broan- NuTone.com 800-558-1711. In Canada – Broan-NuTone.ca 800-567-3855
BIAQHWRS100 Wiring Diagram
Power Supplied to Switch Box
Regulatory Information
The OvertureTM Hardwired Room Sensor 1110725 is certified to comply with
applicable FCC and IC rules and regulations governing RF and EMI emissions.
Refer to 1110725.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation. The distance between user and device should be no less than 20 cm.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
ISED Compliance Statement
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s license-exempt
RSS(s).
Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The Bluetooth® word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc. and any use of such marks by Broan-NuTone LLC is under
license. Other trademarks and trade names are those of their respective
owners.
The Android robot is reproduced or modified from work created and shared by
Google and used according to terms described in the Creative Commons 3.0
Attribution License.
Regulatory ID for 1110725 OvertureTM Hardwired Room Sensor
- FCC ID: 2ADLL-1110725
- IC: 2143B-1110725
CAN ICES-003(B) / NMB-003(B)
Made in China to the quality standards and specifications of Broan-NuTone LLC,
926 West State Street, Hartford, Wisconsin, USA 53027 Broan-NuTone.com
800-558-1711
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville Québec Canada J2C 7W9
Broan-NuTone.ca 800-567-3855
For more information and user manuals scan QR code below.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>