NI-5753 National Instruments Digitizer Adapter Module
Product Information
- Product Name: NI 5753
- Product Type: FlexRIO Adapter Module
- Description: The NI 5753 is a FlexRIO adapter module designed to work in conjunction with FlexRIO FPGA modules and Controllers for FlexRIO. It is available in two variants, the -01 and the -02, each with different channel configurations and coupling options.
Variant | Channels | Accuracy | Sample Rates | Coupling | Output Voltage |
---|---|---|---|---|---|
NI 5753-01 | Sixteen channels | 16-bit accuracy | Up to 125 MS/s (default 120 | ||
MS/s) | AC-coupled | 1.8 Vpp (+9.1 dBm) | |||
NI 5753-02 | Twelve channels | 16-bit accuracy | Up to 125 MS/s (default 120 | ||
MS/s) | DC-coupled | 0.9 Vpp (+3.2 dBm) |
Product Usage Instructions
Installation and Configuration
Before you begin, complete the software and hardware installation
instructions in the Getting Started guide for your FlexRIO FPGA module or
Controller for FlexRIO.
To install and configure the NI 5753, follow these steps:
- Refer to the Electromagnetic Compatibility Guidelines section in the product documentation to ensure proper usage in different environments.
- Connect the NI 5753 adapter module to the appropriate FlexRIO FPGA module or Controller for FlexRIO.
- Ensure that the connections are secure and properly seated.
- Follow the clocking instructions provided in the Clocking section of the product documentation.
- Refer to the Block Diagram section for an overview of the internal components and their connections.
- If desired, refer to the Component-Level Intellectual Property (CLIP) sections for additional information on specific features and functionality.
Electromagnetic Compatibility Guidelines
This product complies with regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. To
minimize interference and ensure proper performance, follow these guidelines:
- Use this product in industrial locations as intended.
- In residential or commercial areas, be aware that harmful interference may occur. Follow the instructions in the product documentation to prevent unacceptable performance degradation.
- Install and use this product strictly according to the instructions provided to minimize interference with radio and television reception.
- Do not make any modifications to the product that are not expressly approved by National Instruments, as it may void your authority to operate the product under local regulatory rules.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and
limits for electromagnetic compatibility (EMC) stated in the product
specifications. These requirements and limits are designed to provide
reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment. This product
is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral
device or test object, or if the product is used in residential or commercial
areas. To minimize interference with radio and television reception and
prevent unacceptable performance degradation, install and use this product in
strict accordance with the instructions in the product documentation.
Furthermore, any modifications to the product not expressly approved by
National Instruments could void your authority to operate it under your local
regulatory rules.
Caution To ensure the specified EMC performance, operate this product
only with shielded cables and accessories.
Caution To ensure the specified EMC performance, the length of all I/O
cables must be no longer than 3 m (10 ft).
FlexRIO Documentation
Table 1. FlexRIO Documentation Locations and Descriptions
Document | Location | Description |
---|---|---|
Getting started guide | Available from the Start | Contains installation |
instructions for
for your FlexRIO| menu and at ni.com/| your
FlexRIO system.
FPGA module or| manuals.|
Controller for FlexRIO| |
Specifications| Available from the Start| Contains specifications for your
document for your| menu and at ni.com/|
FlexRIO FPGA module or Controller
FlexRIO FPGA module| manuals.| for FlexRIO.
or Controller for| |
FlexRIO| |
Document| Location| Description
---|---|---
Getting started guide for your adapter module| Available from the Start menu
and at ni.com/
manuals.| Contains signal information,
examples, and CLIP details for your adapter module.
Specifications document for your adapter module| Available from the Start menu
and at ni.com/
manuals.| Contains specifications for your
adapter module.
LabVIEW FPGA
Module Help
| Embedded in LabVIEW Help and at ni.com/
manuals.| Contains information about the basic
functionality of the LabVIEW FPGA Module.
Real-Time Module Help| Embedded in LabVIEW Help and at
ni.com/
manuals.| Contains information about real-time
programming concepts, step-by-step instructions for using LabVIEW with the
Real-Time Module, reference information about Real-Time Module VIs and
functions, and information about LabVIEW features on real-time operating
systems.
FlexRIO Help| Available from the Start menu and at
ni.com/
manuals.| Contains information about the FPGA
module front panel connectors and I/O, controller for FlexRIO front panel
connectors and I/O, programming instructions, and adapter module component-
level IP (CLIP).
LabVIEW Examples| Available in NI Example Finder. In LabVIEW, click Help »
Find Examples » Hardware Input and Output » FlexRIO.| Contains
examples of how to run FPGA VIs and Host VIs on your device.
IPNet| Located at ni.com/ipnet.| Contains
LabVIEW FPGA functions and intellectual property to share.
FlexRIO product page| Located at
ni.com/flexrio.| Contains product information
and data sheets for FlexRIO devices.
FlexRIO Examples
FlexRIO includes several example applications for LabVIEW. These examples serve as interactive tools, programming models, and as building blocks in your own applications.
Accessing FlexRIO Examples
FlexRIO examples are available in LabVIEW’s NI Example Finder. Complete the
following steps to access the examples by task.
- In LabVIEW, click Help»Find Examples.
- In the NI Example Finder window that appears, click Hardware Input and Output»
FlexRIO.
The examples are sorted by task. Click on an example and refer to the
Information window for a description of the example. Refer the Requirements
window for a list of hardware devices that can run the example. You can also
click the Search tab to search all installed examples by keyword. For example,
search for FlexRIO to locate all FlexRIO examples. Examples also are available
online that demonstrate FlexRIO basics, such as using DRAM, acquiring data
from adapter modules, and performing high throughput streaming. Refer to
ni.com/examples. for these examples and for more
information.
Verifying the System Requirements
To use the NI 5753, your system must meet certain requirements. For more
information about minimum system requirements, recommended system, and
supported application development environments (ADEs), refer to the readme,
which is available on the software media or online at
ni.com/updates.
Unpacking
Caution To prevent ESD from damaging the devices, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.
- Touch the antistatic package to a metal part of the computer chassis.
- Remove each module from the package and inspect it for loose components or any other sign of damage.
- Caution Never touch the exposed pins of connectors.
- Note Do not install a device if it appears damaged in any way.
- Unpack any other items and documentation from the kit. Store the devices in the antistatic package when they are not in use.
Preparing the Environment
Ensure that the environment you are using the NI 5753 it meets the following specifications. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) 0 °C to 55 °C
- Operating humidity (IEC 60068-2-56) 10% to 90% RH, non-condensing
- Pollution Degree 2
- Maximum altitude 2,000 m at 25 °C ambient temperature Indoor use only.
Note Refer to the NI 5753 Specifications at ni.com/manuals for complete
specifications.
Caution Clean the hardware with a soft, nonmetallic brush. Make sure that
the hardware is completely dry and free from contaminants before returning it
to service.
Installing the NI 5753
Refer to the getting started guide for your FlexRIO FPGA module or Controller
for FlexRIO for instructions about how to install your FlexRIO system,
including the NI 5753.
Confirming that Measurement & Automation Explorer (MAX) Recognizes the
Device
Use Measurement & Automation Explorer (MAX) to configure your NI hardware. MAX informs other programs about which devices reside in the system and how they are configured. MAX is automatically installed with FlexRIO Support.
- Launch MAX by navigating to Start»All Programs»National Instruments»NI MAX or by clicking the NI MAX desktop icon.
- In the Configuration pane, double-click Devices and Interfaces to see the list of installed devices. Installed devices appear under the name of their associated chassis.
- (PXI and PXI Express devices only) Expand your Chassis tree item. MAX lists all devices installed in the chassis. Your default device names may vary.
- Note If you do not see your hardware listed, press
to refresh the list of installed devices. If the device is still not listed, power off the system, ensure the device is correctly installed, and restart.
- Note If you do not see your hardware listed, press
- (Controllers for FlexRIO only) Your device appears under the Remote Devices section.
Connecting Cables to the NI 5753
- Use any shielded 50 Ω SMA cable to connect signals to the CLK IN connector on the front panel of your NI 5753.
- Use the SHH19-H19-AUX cable (NI part number: 152629-01 or 152629-02) to connect to the digital I/O (DIO) and programmable function interface (PFI) signals on the AUX I/O connector. NI recommends using the SCB-19 connector block to access the DIO and PFI signals.
- Use an MCX connector to connect signals to the analog input connector on the front panel. You can connect each channel with an individual cable, or you can use the ganged, 16-channel, male MCX to female SMA cable (part number 785244-01).
Accessories
The NI 5753 can be used with the SCB-19 shielded desktop connector block.
Refer to the SCB-19 User Guide for information about how to connect and use
the SCB-19 with the AUX I/O front panel connector on your NI 5753.
Front Panel and Connector Pinouts
The following figure shows the front panel connectors for the NI 5753.
Caution To avoid permanent damage to the NI 5753, disconnect all signals
connected to the NI 5753 before powering down the module, and connect signals
only after the adapter module has been powered on by the FlexRIO FPGA module
or Controller for FlexRIO.
Caution Connections that exceed any of the maximum ratings of any
connector on the NI 5753 can damage the device and the chassis. NI is not
liable for any damage resulting from such connections.
AUX I/O Connector
Table 2. NI 5753 AUX I/O Connector Pin Assignments
Caution The AUX I/O connector accepts a standard, third-party HDMI cable,
but the AUX I/O port is not an HDMI interface. Do not connect the AUX I/O port
on the NI 5753 to the HDMI port of another device. NI is not liable for any
damage resulting from such signal connections.
Block Diagram
The following figure shows the NI 5753 block diagram and signal flow.
Figure 1. NI 5753 Block DiagramThe AI 12 – AI 15 channels are unpopulated on the NI 5753-02
variant.
Component-Level Intellectual Property (CLIP)
The LabVIEW FPGA Module includes component-level intellectual property (CLIP) for HDL IP integration. FlexRIO devices support two types of CLIP: user- defined and socketed.
- User-defined CLIP allows you to insert HDL IP into an FPGA target, enabling VHDL code to communicate directly with an FPGA VI.
- Socketed CLIP provides the same IP integration of the user-defined CLIP, but it also allows the CLIP to communicate directly with circuitry external to the FPGA. Adapter module socketed CLIP allows your IP to communicate directly with both the FPGA VI and the external adapter module connector interface.
The FlexRIO adapter module ships with socketed CLIP items that add module I/O
to the LabVIEW project.
NI 5753 AC-Coupled CLIP
The NI 5753 AC-coupled CLIP provides access to sixteen AC-coupled 16-bit 120
MS/s analog input channels, eight bidirectional DIO channels, and four
bidirectional PFI channels. It also provides a User Command Interface to send
raw SPI and I2C accesses to the adapter module for low-level configuration,
and to select the clock modes:
- Internal Sample Clock (free-running)
- Internal Sample Clock locked to an external Reference Clock through the CLK/REF IN front panel connector
- Internal Sample Clock locked to an external Reference Clock through IoModSyncClock
- 70 MHz to 125 MHz external Sample Clock through the CLK/REF IN front panel connector
- 70 MHz to 125 MHz external Sample Clock through IoModSyncClock
In the LabVIEW FPGA Module, 16-bit analog input data is accessed using an I16
data type. The DIO signals are grouped into two ports of four signals each and
are accessed using a U8 data type and a Boolean write enable signal. The four
PFI signals are accessed individually using Boolean signals.
Related Information
Refer to the FlexRIO Help for more information about FlexRIO CLIP items, how
to configure the NI 5753 with a socketed CLIP, and for a list of available
socketed CLIP signals.
NI 5753 DC-Coupled CLIP
The NI 5753 DC-coupled CLIP provides access to twelve DC-coupled 16-bit 120
MS/s analog input channels, eight bidirectional DIO channels, and four
bidirectional PFI channels. This module also contains a set of digital-to-
analog converters (DACs) to trim larger DC offset errors induced by the
coupling amplifier and system DC mismatch. This CLIP also provides a User
Command Interface to send raw SPI and I2C accesses to the adapter module for
low-level configuration, and to select the clock modes:
- Internal Sample Clock (free-running)
- Internal Sample Clock locked to an external Reference Clock through the CLK/REF IN front panel connector
- Internal Sample Clock locked to an external Reference Clock through IoModSyncClock
- 70 MHz to 125 MHz external Sample Clock through the CLK/REF IN front panel connector
- 70 MHz to 125 MHz external Sample Clock through IoModSyncClock
In the LabVIEW FPGA Module, 16-bit analog input data is accessed using an I16
data type. The DIO signals are grouped into two ports of four signals each and
are accessed using a U8 data type and a Boolean write enable signal. The four
PFI signals are accessed individually using Boolean signals.
Related Information
Refer to the FlexRIO Help for more information about FlexRIO CLIP items, how
to configure the NI 5753 with a socketed CLIP, and a list of available
socketed CLIP signals.
Clocking
The NI 5753 clock source controls the sample rate and other timing functions
on the device. The following table contains information about the possible NI
5753 clock sources.
Clock Source | Frequency | Description |
---|---|---|
Internal Sample Clock | 120 MHz | The internal Sample Clock is free- running. |
Internal Sample Clock locked to an external Reference Clock through the
CLK/REF IN front panel connector| 10 MHz| The internal Sample Clock can be
locked to an external Reference Clock through the CLK/REF IN front panel
connector.
Internal Sample Clock locked to an external Reference Clock through
IoModSyncClock| 10 MHz| The internal Sample Clock can be locked to an external
Reference Clock through the IoModSyncClock signal.
Clock Source| Frequency| Description
---|---|---
External Sample Clock through the CLK/REF IN front panel connector| 70 MHz to
125 MHz
| An external Sample Clock can be provided from the CLK/REF IN front panel
connector.
External Sample Clock through IoModSyncClock| 70 MHz to
125 MHz
| An external Sample Clock can be provided from the IoModSyncClock signal via the DSTARA line.
Related Information
Refer to the FlexRIO Help for more information about the NI 5753 clocks.
Worldwide Support and Services
The NI website is your complete resource for technical support. At
ni.com/support, you have access to everything from
troubleshooting and application development self-help resources to email and
phone assistance from NI Application Engineers. Visit
ni.com/services. for NI Factory Installation
Services, repairs, extended warranty, and other services. Visit
ni.com/register to register your NI product. Product
registration facilitates technical support and ensures that you receive
important information updates from NI. A Declaration of Conformity (DoC) is
our claim of compliance with the Council of the European Communities using the
manufacturer’s declaration of conformity. This system affords the user
protection for electromagnetic compatibility (EMC) and product safety. You can
obtain the DoC for your product by visiting
ni.com/certification. If your product supports
calibration, you can obtain the calibration certificate for your product at
ni.com/calibration. NI corporate headquarters is
located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also
has offices located around the world. For telephone support in the United
States, create your service request at ni.com/support
or dial 1 866 ASK MYNI (275 6964). For telephone support outside the United
States, visit the Worldwide Offices section of
ni.com/global to access the branch office websites,
which provide up-to-date contact information, support phone numbers, email
addresses, and current events.
Where to Go Next
Refer to the following figure for information about other product tasks and
associated resources for those tasks.
GETTING STARTED GUIDE
NI 5753 120 MS/s Adapter Module Note Before you begin, complete the software
and hardware installation instructions in the getting started guide for your
FlexRIO FPGA module or Controller for FlexRIO. The NI 5753 is a FlexRIO
adapter module designed to work in conjunction with FlexRIO FPGA modules and
Controllers for FlexRIO.The NI 5753 is available in two variants, the -01 and
the -02. The following table lists the key features of each variant.
NI 5753-01 | NI 5753-02 |
---|---|
Sixteen channels | Twelve channels |
16-bit accuracy | 16-bit accuracy |
Sample rates up to 125 MS/s (default 120 MS/s) | Sample rates up to 125 MS/s |
(default 120 MS/s)
AC-coupled| DC-coupled
1.8 Vpp (+9.1 dBm)| 0.9 Vpp (+3.2 dBm)
This document explains how to install and configure the NI 5753.
INSTRUCTION
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on NI trademarks. Other product andcompany names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help» Patents in your software, the patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third- party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export- compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015. © 2016 National Instruments. All rights reserved. 375441A-01 Sep16
References
- Test and Measurement Systems, a part of Emerson - NI
- Test and Measurement Systems, a part of Emerson - NI
- Product Certifications - NI
- Example Programs - NI Community
- What Is FlexRIO? - NI
- NI Learning Center - NI
- Support - NI
- Product Documentation - NI
- Log In - National Instruments
- NI Services - NI
- Support - NI
- NI Trademarks and Logo Guidelines - NI
- Software and Driver Downloads - NI
- Product Certifications - NI
- Example Programs - NI Community
- What Is FlexRIO? - NI
- Support - NI
- Product Documentation - NI
- Product Documentation - NI
- Contact Us - NI
- Log In - National Instruments
- NI Services - NI
- Support - NI
- Software and Driver Downloads - NI
- NI-5753 National Instruments Digitizer Adapter Module for FlexRIO | Apex Waves
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>