RUNTRU E4HL5042A1000A Split System Heat Pump Owner’s Manual

June 12, 2024
RunTru

Submittal
Split System Heat Pump
E4HL5042A1000A

E4HL5042A-SUB-1A-EN

NOTE: “Graphics in this document are for representation only. Actual model may differ in appearance.”

Outline Drawing

Model A B C D E F G H
E4HL5042A1000A 52.40 37.40 13.39 14.76 16.10 4.00 6.37 3.75

All dimensions are in inches

NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS

SOUND POWER LEVEL

Model| A-Weighted Sound Power Level [dB(A)]| Full Octave Sound Power [dB]
63Hz| 125Hz| 250Hz| 500Hz| 1000Hz| 2000Hz| 4000Hz| 8000Hz
E4HL5042A1000A| 68| 66| 62| 60| 63| 67| 57| 48| 38
Note: Rated in accordance with AHRI Standard 270–2015
For reference only.

Product Specifications

OUTDOOR UNIT (a) E4HL5042A1000A
POWER CONNS. — V/PH/HZ (b) 208/230/1/60
MIN. CIR. AMPACITY 31
MAX. OVERCURRENT PROTECTION 50
COMPRESSOR Rotary
NO. USED — NO. STAGES 1-VARIBLE
VOLTS/PH/HZ 208/230/1/60
R.L. AMPS (c) 21.6
FACTORY INSTALLED
START COMPONENTS (d) NO
INSULATION/SOUND BLANKET YES
COMPRESSOR HEAT NO
OUTDOOR FAN PROPELLER
DIA. (IN.) — NO. USED 20-7/8″-2
TYPE DRIVE — NO. SPEEDS DIRECT — VARIBLE
NO. MOTORS — HP 2-1/10
CFM @ 0.0 IN. W.G. (e) 4200
MOTOR SPEED R.P.M. 850
VOLTS/PH/HZ 208/230/1/60
F.L. AMPS 1.45
OUTDOOR COIL — TYPE PLATE FIN
ROWS — F.P.I. 2-17
FACE AREA (SQ. FT.) 14.34
TUBE SIZE (IN.) 3/8″
REFRIGERANT CONTROL ELEC. EXPANSION VALVE

REFRIGERANT
LBS. – R-410A (O.D. UNIT) (f)| 9 LBS, 14 OZ
FACTORY SUPPLIED| YES
LINE SIZE — IN. O.D. GAS| 7/8″
LINE SIZE — IN. O.D. LIQ.| 3/8″
CHARGING SPECIFICATIONS
SUBCOOLING| 5°F
DIMENSIONS| H x W x D
CRATED (IN.)| 41-3/8″×54″×19-1/8″
UNCRATED (IN.)| 37-3/8″×52-3/8″×14- 3/8″
WEIGHT
Shipping| 238
Net (Lbs.)| 231

(a) Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
(b) Calculated in accordance with Natl. Elec.
Codes. Use only HACR circuit breakers or fuses.
(c) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
(d) No means no start components.
(e) Standard Air — Dry Coil — Outdoor
(f) This value is approximate. For more precise value see unit nameplate.

Mechanical Specification Options

General
The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 60335-2-40. Exterior is designed for outdoor application.
Casing
Unit is painted with a glossy corrosion resistant finish on all panels. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. All panels are subjected to our 500 hour salt spray test.
Refrigerant Controls
Refrigeration system controls include condenser fan, compressor drive and low pressure switches.
Compressor
The compressor features external over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grilles and panels.
Low Ambient Cooling
As manufactured, this system has a cooling capacity to 5°F.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com

The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org.
The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

E4HL5042A-SUB-1A-EN 24 Apr 2023
Supersedes (New)
©2023

Documents / Resources

| RUNTRU E4HL5042A1000A Split System Heat Pump [pdf] Owner's Manual
E4HL5042A1000A, E4HL5042A1000A Split System Heat Pump, E4HL5042A1000A Heat Pump, Split System Heat Pump, Split System, Heat Pump, Pump
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals