RunTru by Trane E4HL5030A1000A Split System Heat Pump Instruction Manual

June 12, 2024
RunTru by Trane

RunTru by Trane E4HL5030A1000A Split System Heat Pump

Outline Drawing

RunTru-by-Trane-E4HL5030A1000A-Split-System-Heat-Pump-
fig-1

Model A B C D E F G H I
E4HL5030A1000A 31.35 35.83 14.13 15.36 16.59 5.97 6.07 3.71 6.09

All dimensions are in inches

NOTE: “Graphics in this document are for representation only. The actual model may differ in appearance

NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS

SOUND POWER LEVEL

Model| A-Weighted Sound

Power Level [dB(A)]

| Full Octave Sound Power [dB]
63Hz| 125Hz| 250Hz| 500Hz| 1000Hz| 2000Hz| 4000Hz| 8000Hz
E4HL5030A1000A| 62| 60| 56| 53| 54| 59| 55| 42| 34
Note: Rated in accordance with AHRI Standard 270–2015
For reference only.

Product Specifications

OUTDOOR UNIT (a) E4HL5030A1000A
POWER CONNS. — V/PH/HZ (b) 208/230/1/60
MIN. CIR. AMPACITY 22

MAX. OVERCURRENT

PROTECTION

| 35
COMPRESSOR| Rotary
NO. USED — NO. STAGES| 1-VARIBLE
VOLTS/PH/HZ| 208/230/1/60
R.L. AMPS (c)| 15.8
FACTORY INSTALLED|
START COMPONENTS (d)| NO
INSULATION/SOUND BLANKET| YES
COMPRESSOR HEAT| NO
OUTDOOR FAN| PROPELLER
DIA. (IN.) — NO. USED| 21-5/8″-1
TYPE DRIVE — NO. SPEEDS| DIRECT — VARIBLE
NO. MOTORS — HP| 1-1/10
CFM @ 0.0 IN. W.G. (e)| 2300
MOTOR SPEED R.P.M.| 850
VOLTS/PH/HZ| 208/230/1/60
F.L. AMPS| 1.1
OUTDOOR COIL — TYPE| PLATE FIN
ROWS — F.P.I.| 3-17
FACE AREA (SQ. FT.)| 8.18
TUBE SIZE (IN.)| 1/4″
REFRIGERANT CONTROL| ELEC. EXPANSION

VALVE

REFRIGERANT|
LBS. – R-410A (O.D. UNIT) (f)| 7 LBS, 4 OZ
FACTORY SUPPLIED| YES
LINE SIZE — IN. O.D. GAS| 3/4″
LINE SIZE — IN. O.D. LIQ.| 3/8″
CHARGING SPECIFICATIONS|
SUBCOOLING| 5°F
DIMENSIONS| H x W x D
CRATED (IN.)| 40-1/4″×32-7/8″×18-

7/8″

UNCRATED (IN.)| 35-3/4″×31-5/8″×14-

1/8″

WEIGHT|
Shipping| 176
Net (Lbs.)| 121

  • Certified in accordance with the Air-SourceUnitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
  • Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
  • This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
  • No means no start components.
  • Standard Air — Dry Coil — Outdoor
  • This value is approximate. For more precise values see the unit nameplate.

Mechanical Specification Options

General
The outdoor condensing units are factory charged with the system charge required for the outdoor condensing unit, ten (10) feet of tested connecting line, and the smallest rated indoor evaporative coil match. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 60335-2-40. The exterior is designed for outdoor application.

Casing
The unit is painted with a glossy corrosion-resistant finish on all panels. The unit casing is constructed of heavy gauge, galvanized steel, and painted with a weather-resistant powder paint finish. All panels are subjected to our 500-hour salt spray test.

Refrigerant Controls
Refrigeration system controls include condenser fans, compressor drives, and low-pressure switches.

Compressor
The compressor features external over temperature and pressure protection. Other features include a Centrifugal oil pump and low vibration and noise.

Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grilles and panels.

Low Ambient Cooling
As manufactured, this system has a cooling capacity of 5°F.

About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com

The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

  • E4HL5030A-SUB-1A-EN 24 Apr 2023 Supersedes (New)