RunTru by Trane E4HL5030A1000A Split System Heat Pump
Outline Drawing
Model | A | B | C | D | E | F | G | H | I |
---|---|---|---|---|---|---|---|---|---|
E4HL5030A1000A | 31.35 | 35.83 | 14.13 | 15.36 | 16.59 | 5.97 | 6.07 | 3.71 | 6.09 |
All dimensions are in inches
NOTE: “Graphics in this document are for representation only. The actual model may differ in appearance
NOTE: ALL DIMENSIONS ARE REFERENCE DIMENSIONS
SOUND POWER LEVEL
Model| A-Weighted Sound
Power Level [dB(A)]
| Full Octave Sound Power [dB]
63Hz| 125Hz| 250Hz| 500Hz| 1000Hz| 2000Hz| 4000Hz| 8000Hz
E4HL5030A1000A| 62| 60| 56| 53| 54| 59| 55| 42| 34
Note: Rated in accordance with AHRI Standard 270–2015 For reference only.
Product Specifications
OUTDOOR UNIT (a) | E4HL5030A1000A |
---|---|
POWER CONNS. — V/PH/HZ (b) | 208/230/1/60 |
MIN. CIR. AMPACITY | 22 |
MAX. OVERCURRENT
PROTECTION
| 35
COMPRESSOR| Rotary
NO. USED — NO. STAGES| 1-VARIBLE
VOLTS/PH/HZ| 208/230/1/60
R.L. AMPS (c)| 15.8
FACTORY INSTALLED|
START COMPONENTS (d)| NO
INSULATION/SOUND BLANKET| YES
COMPRESSOR HEAT| NO
OUTDOOR FAN| PROPELLER
DIA. (IN.) — NO. USED| 21-5/8″-1
TYPE DRIVE — NO. SPEEDS| DIRECT — VARIBLE
NO. MOTORS — HP| 1-1/10
CFM @ 0.0 IN. W.G. (e)| 2300
MOTOR SPEED R.P.M.| 850
VOLTS/PH/HZ| 208/230/1/60
F.L. AMPS| 1.1
OUTDOOR COIL — TYPE| PLATE FIN
ROWS — F.P.I.| 3-17
FACE AREA (SQ. FT.)| 8.18
TUBE SIZE (IN.)| 1/4″
REFRIGERANT CONTROL| ELEC. EXPANSION
VALVE
REFRIGERANT|
LBS. – R-410A (O.D. UNIT) (f)| 7 LBS, 4 OZ
FACTORY SUPPLIED| YES
LINE SIZE — IN. O.D. GAS| 3/4″
LINE SIZE — IN. O.D. LIQ.| 3/8″
CHARGING SPECIFICATIONS|
SUBCOOLING| 5°F
DIMENSIONS| H x W x D
CRATED (IN.)| 40-1/4″×32-7/8″×18-
7/8″
UNCRATED (IN.)| 35-3/4″×31-5/8″×14-
1/8″
WEIGHT|
Shipping| 176
Net (Lbs.)| 121
- Certified in accordance with the Air-SourceUnitary Air-conditioner Equipment certification program, which is based on AHRI standard 210/240.
- Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
- This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
- No means no start components.
- Standard Air — Dry Coil — Outdoor
- This value is approximate. For more precise values see the unit nameplate.
Mechanical Specification Options
General
The outdoor condensing units are factory charged with the system charge
required for the outdoor condensing unit, ten (10) feet of tested connecting
line, and the smallest rated indoor evaporative coil match. This unit is
designed to operate at outdoor ambient temperatures as high as 115°F. Cooling
capacities are matched with a wide selection of air handlers and furnace coils
that are AHRI certified. The unit is certified to UL 60335-2-40. The exterior
is designed for outdoor application.
Casing
The unit is painted with a glossy corrosion-resistant finish on all panels.
The unit casing is constructed of heavy gauge, galvanized steel, and painted
with a weather-resistant powder paint finish. All panels are subjected to our
500-hour salt spray test.
Refrigerant Controls
Refrigeration system controls include condenser fans, compressor drives, and
low-pressure switches.
Compressor
The compressor features external over temperature and pressure protection.
Other features include a Centrifugal oil pump and low vibration and noise.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer.
The coil is protected on all four sides by grilles and panels.
Low Ambient Cooling
As manufactured, this system has a cooling capacity of 5°F.
About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy-efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com
The AHRI Certified mark indicates company participation in the AHRI Certification program. For verification of individual certified products, go to ahridirectory.org. The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.
- E4HL5030A-SUB-1A-EN 24 Apr 2023 Supersedes (New)