RunTru A4AH4E36A1C30A Submittal 3.0 Ton Convertible Air Handler Instruction Manual
- June 12, 2024
- RunTru
Table of Contents
Submittal
3.0 Ton
Convertible Air Handler
A4AH4E36A1C30A
September 2022
A4AH4E36A1C-SUB-1A-EN
Outline Drawing
| |
---|---|---
M I N I M UM U N I T CL EA R A NCE TABLE
| SER V I CE CLEA R A NCE
(R ECOM M E N DED )
SIDES| 2″
FRONT| 2 I”
BACK| 0″
INLET DUCT| I”
OUTLET DUCT| N / A
NOTE: THIS UNIT IS APPROVED FOR INSTALLATION CLEARANCES TO COMBUSTIBLE MATERIAL AS STATED ON THE UNIT RATING NAMEPLATE
ALL DIMENSIONS ARE REFERENCE DIMENSIONS
PRODU CT DIMENSIONS
Air Handler Model| A| B| c| D| E| F| H| Flow Control| Gas Line Braze
A4AH4E36A 1C30A| 51.27| 23.50| 21.50| 21.75| 7.01| 9.66| 24.59| TXV| 7/8
All dimensions are in inches
Product Specifications
MODEL | A4AH4E36A1C30A |
---|---|
RATED VOLTS/PH/HZ | 208-230/ 1/60 |
RATINGS(a) | See O.D. Specifications |
INDOOR COIL -Type | Plate Fin |
Rows – F.P.I. | 4 – 14 |
Face Area (sq. ft.) | 4.59 |
Tube Size (in.) | 3/8 |
Refrigerant Control | TXV |
Drain Conn. Size (in.) (b) | 3/4 NPT |
DUCT CONNECTIONS | See Outline Drawing |
INDOOR FAN – Type | Centrifugal |
Diameter-Width ( n.) | 11X 8 |
No. Used | 1 |
Drive – No. Speeds | Direct – 5 Ccl |
CFM vs. in. w.g. | See Fan Performance Table |
No. Motors – H.P. | 1- 1/2 |
Motor Speed R.P.M. | 1050 |
Volts/ Ph/Hz | 208-230/ 1/60 |
F.L. Amps | 4.1 |
FILTER | |
Filter Furnished? (b) | No |
REFRIG ERANT | R-410A |
Ref. Line Connections | Brazed |
Coupling or Conn. Size – in. Gas | 7/8 |
Coupling or Conn. Size – in. Liq. | 3/8 |
DIM ENSIONS | H x W x D |
Crated ( n.) | 52-3/4 x 27-1/2 x 25-1/2 |
Uncrated | 51-3/8 x 23-1/2 x 21-1/8 |
WEIGHT | |
Shipping (Lbs.)I Net (Lbs.) | 155/ 144 |
(a) These Air Handlers are A.H.R.I certified with various Split System Air
Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System
Outdoor Unit Product Data Guides for performance data.
(b) 3/4″ Male Plastic Pipe (Ref: ASTM 178576)
(c) ECM Motor
(d) Remote filter required.
Minimum Airflow CFM
A4AH4E36A1C30A
Heater| Minimum Heat Speed Tap
| With Heat Pump| Without Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG,
BAYHTR1505BRK, BAYHTR1505LUG| Low| Low
BAYHTR1508BRK, BAYHTR1508LUG,
BAYHTR1510BRK, BAYHTR1510LUG| Med-High| Med-Low
BAYHTR1523BRK| Med-High| Med
BAYHTR1517BRK,BAYHTR3517LUG,
BAYHTR3510LUG| High| Med
Heater Pressure Drop Table
Airflow
CFM| Number of Racks| | Heater Racks
---|---|---|---
1| 2| 3| 4| Heater Model| No. of Racks
Air Pressure Drop -Inches W.G.| BAYHTR 1504| 1
1800| 0.02| 0.04| 0.06| 0.14| BAYHTR 1505| 1
1700| 0.02| 0.04| 0.06| 0.14| BAYHTR 1508| 2
1600| 0.02| 0.04| 0.06| 0.13| BAYHTR 1510| 2
1500| 0.02| 0.04| 0.06| 0.12| BAYHTR 1517| 3
1400| 0.02| 0.04| 0.06| 0.12| 6AYHTR3510| 3
1300| 0.02| 0.04| 0.05| 0.11| BAYHTR3517| 3
1200| 0.01| 0.04| 0.05| 0.10| BAYHTR3515| 3
1100| 0.01| 0.03| 0.05| 0.09| BAYHTR 1523| 4
1000| 0.01| 0.03| 0.04| 0.09| BAYHTR 1525| 4
900| 0.01| 0.03| 0.04| 0.08| |
800| 0.01| 0.03| | | |
700| 0.01| 0.02| | | |
600| 0.01| 0.02| | | |
Performance and Electrical Data
- See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters.
- Heater model numbers may have additional suffix digits.
Table 1. Air Flow Performance
A4AH4E36A1C30A
EXTERNAL STATIC
(in w.g)| A RFLOW
Speed Taps: 208 – 230 VOLTS
| High| Med-High| Med t| Med-Low| Low
0.1| 1492| 1418| 1302| 1268| 1140
0.2| 1460| 1385| 1266| 1230| 1096
0.3| 1426| 1349| 1228| 1190| 1050
0.4| 1390| 1311| 1187| 1147| 1002
0.5| 1352| 1271| 1144| 1101| 952
0.6| 1311| 1229| 1099| 1053| 899
0.7| 1269| 1184| 1051| 1003| 845
1. Values are with wet coil, no filter, and no heaters
2. CFM Correction for dry coil = Add 3%
3. † = Factory Setting
4. In downflow applications, airflow must not exceed 1600 cfm due to
condensate blowoff.
5. Low = Tap 1,Med-Low = Tap 2, Med = Tap 3, Med-High= Tap 4, High = Tap 5
Table 2. Electrical Data
A4AH4E36A1C30A
Heater Model No.| No. of Circuits/ Phases| 240 Volt| 208 V
Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity| Maximum Overload
Protection| Capacity| Heater Amps per Circuit| Minimum Circuit Ampacity|
Maximum Overload Protection
kW| BTUH| kW| BTUH
No Heater| | | | 4.1| 5| lS| | | 4.1| s| 15
BAYHTR1S04BRK BAYHTR1S04LUG| 1/ 1| 3.8| 13100| 16.0| 25| 25| 2.9| 9800| 13.8|
22| 2S
BAYHTRlSOSBRK BAYHTRlSOSLUG| 1/ 1| 4.8| 16400| 20.0| 30| 30| 3.6| 12300| 17.3|
27| 30
BAYHTR1S08BRK BAYHTR1S08LUG| 1/ 1| 7.7| 26200| 32.0| 45| 4| 5.8| 19700| 27.7|
40| 40
BAYHTRlS OBRK BAYHTRlS OLUG| 1/ 1| 9.6| 32800| 40.0| 55| 60| 7.2| 24600| 34.6|
48| 50
BAYHTR1S17BRK-
Circuit 1(a)| 2/ 1| 9.6| 32800| 40.0| 55| 60| 7.2| 24600| 34.6| 48| 50
BAYHTR1S 7BRK-
Circuit 2| 4.8| 16400| 20.0| 25| 25| 3.6| 12300| 17.3| 22| 25
BAYHTR1S23BRK-
Circuit 1(a)| 2/ 1| 9.6| 32800| 40.0| 55| 60| 7.2| 24600| 34.6| 48| 50
BAYHTR1S23BRK-
Circuit 2| 9.6| 32800| 40.0| 50| 50| 7.2| 24600| 34.6| 43| 45
BAYHTR3S 10LUG| 1/3| 9.6| 32800| 23. 1| 33| 35| 7.2| 24600| 20.0| 30| 30
BAYHTR3S 17LUG| 1/3| 14.4| 49100| 34.6| 48| so| 10.8| 36900| 30.0| 42| 45
BAYHTR1S17BRK
with single circuit power source kit BAYSPEKT201A| 1/ 1| 14.4| 49100| 60.0|
83| 90| 10.8| 36900| 51.9| 73| 80
- = Motor Amps
(a) MCA and MOP for circuit 1 contains the motor amps.
Features and Benefits
- Galvanized metal cabinet with captured foil face insulation
- 2% or less air leakage
- R-4.2 Insulating Value
- Multi-Position UP/Down Flow, Horizontal Left /Right
- ALL Aluminum Coil
- Electric Heaters with polarized plug connections (sold as accessory)
- R-410A Thermal Expansion Valve
- ECM Motor (3..0 – 5 Ton Models)
- Low Voltage Pigtail Connections
- Draw Through Design
- Horizontal Drain pan
- Single Color
- Fused 24V Power
- 5 year warranty
- Optional extended warranty availabel
Important: Condensate management kit is required for all 5 ton air handler models installed in downflow applications.
About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor
environments for residential applications. For more information, please visit
www.trane.com or
www.americanstandardair.com.