CHAMPION POWER EQUIPMENT 100814 7500W Electric Start Generator User Manual
- June 12, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
OPERATOR’S MANUAL
MODEL #100814
7500W ELEcTRic START
GENERATOR
100814 7500W Electric Start Generator
REGISTER YOUR PRODUCT ONLINE at championpowerequipment.com
TAKEYOURGENERATOROUTSIDE.COM
or visit championpowerequipment.com
READ AND SAVE THiS MANUAL. This manual contains important safety
precautions which should be read and understood before operating the product.
Failure to do so could result in serious injury. This manual should remain
with the product.
Specifications, descriptions and illustrations in this manual are as accurate
as known at the time of publication, but are subject to change without notice.
CARBON MONOXIDE KILLS
CARBON MONOXIDE SAFETY: THE BIG PICTURE
As the only safe way to use a portable generator, taking your generator
outside is absolutely mandatory to keep your family safe from carbon monoxide.
But there’s even more you can do. By educating yourself about all carbon
monoxide risks, you’ll be better prepared to protect your family from this
colorless, oderless threat.
ALWAYS READ THE OPERATOR’S MANUAL FIRST
KNOW THE SYMPTOMS
- Headache
- Nausea
- Shortness of breath
- Dizziness
- Fatigue
STAY ALERT WITH CARBON MONOXIDE DETECTORS KEEP IT OUTSIDE AND AWAY FROM DOORS,
WINDOWS, AND GARAGES IF YOU FEEL SYMPTOMS,LEAVE RIGHT AWAY POINT FUMES AWAY
FROM NEARBY PEOPLE
www.TakeYourGeneratorOutside.com
INTRODUcTiON
Congratulations on your purchase of a Champion Power Equipment (CPE) product.
CPE designs, builds, and supports all of our products to strict specifications
and guidelines. With proper product knowledge, safe use, and regular
maintenance, this product should bring years of satisfying service.
Every effort has been made to ensure the accuracy and completeness of the
information in this manual at the time of publication, and we reserve the
right to change, alter and/or improve the product and this document at any
time without prior notice.
Since CPE highly values how our products are designed, manufactured, operated
and are serviced, and also highly value your safety and the safety of others,
we would like you to take the time to review this product manual and other
product materials thoroughly and be fully aware and knowledgeable of the
assembly, operation, dangers and maintenance of the product before use.
Fully familiarize yourself, and make sure others who plan on operating the
product fully familiarize themselves too, with the proper safety and operation
procedures before each use. Please always exercise common sense and always err
on the side of caution when operating the product to ensure no accident,
property damage, or injury occurs. We want you to continue to use and be
satisfied with your CPE product for years to come.
When contacting CPE about parts and/or service, you will need to supply the
complete model and serial numbers of your product.
Transcribe the information found on your product’s nameplate label to the
table below
CPE TECHNICAL SUPPORT TEAM
1-877-338-0999
MODEL NUMBER
100814
SERIAL NUMBER
DATE OF PURCHASE
PURCHASE LOCATION
SAFETY DEFINITIONS
The purpose of safety symbols is to attract your attention to possible
dangers. The safety symbols, and their explanations, deserve your careful
attention and understanding. The safety warnings do not by themselves
eliminate any danger. The instructions or warnings they give are not
substitutes for proper accident prevention measures.
DANGER
DANGER indicates a hazardous situation which,if not avoided, will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury.
IMPORTANT SAFETY INSTRUCTIONS
WARNiNG
Cancer and Reproductive Harm –
www.P65Warnings.ca.gov
DANGER
Generator exhaust contains carbon monoxide, a colorless, odorless, poisonous
gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or
death. If you start to feel dizzy or weak, get to fresh air immediately.
OPERATE GENERATOR OUTDOORS ONLY IN A WELL VENTILATED AREA AND POINT EXHAUST
AWAY.
DO NOT operate the generator inside any building, including garages,
basements, crawlspaces and sheds, enclosure or compartment, including the
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined area through windows, doors,
vents or other openings.
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or
smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.Install battery-
operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery
back-up according to the manufacturer’s instructions.
DANGER
Operate equipment with guards in place.
Rotating parts can entangle hands, feet, hair, clothing and/or accessories.
Traumatic amputation or severe laceration can result.
Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
DO NOT wear loose-fitting clothing, dangling drawstrings or items that could
become caught.
DANGER
Generator produces powerful voltage.
DO NOT touch bare wires or receptacles.
DO NOT use electrical cords that are worn, damaged or frayed.
Use only Champion electrical cords for proper application.
DO NOT operate generator in wet weather.
DO NOT allow children or unqualified persons to operate or service the
generator.
Use a ground fault circuit interrupter (GFCI) in damp areas and areas
containing conductive material such as metal decking.
Connection to your home’s electrical system requires a
listed 30A transfer switch installed by a licensed electrician and approved by
the local authority having jurisdiction. The connection must isolate the
generator from the utility power and must comply with all applicable laws and
electrical codes.
WARNING
Do not use generator for medical and life support uses.
In case of emergency, call 911 immediately.
NEVER use this product to power life support devices or life support
appliances.
NEVER use this product to power medical devices or medical appliances.
Inform your electricity provider immediately if you or anyone in your
household depends on electrical equipment to live.
Inform your electrical provider immediately if a loss of power would cause you
or anyone in your household to experience a medical emergency.
WARNING
Spark from removed spark plug wire can result in fire or electrical shock.
When servicing the generator:
Disconnect the spark plug wire and place it where it cannot contact the plug
or any other metal object.
DO NOT check for spark with the plug removed.
Use only approved spark plug testers.
WARNING
Running engines produce heat. Severe burns can occur on contact. Combustible
material can catch fire on contact.
DO NOT touch hot surfaces.
Avoid contact with hot exhaust gases.
Allow equipment to cool before touching.
Maintain at least 3 ft. (91.4 cm) of clearance on all sides to ensure adequate
cooling.
Maintain at least 5 ft. (1.5 m) of clearance from combustible materials.
** WARNING
Rapid retraction of the recoil cord will pull hand and arm towards the engine
faster than you can let go. Broken bones, fractures, bruises or sprains could
result. Unintentional startup can result in entanglement, traumatic amputation
or laceration.
When starting engine, pull the recoil cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
DO NOT start or stop the engine with electrical devices plugged in and turned
on.
WARNING
Although the generator contains a spark arrester, maintain a minimum distance
of 5 ft. (1.5 m) from dry vegetation to prevent fires.
CAUTION
Exceeding the generator’s running capacity can damage the generator and/or
electrical devices connected to it.
DO NOT overload the generator.
DO NOT tamper with the governed speed.
DO NOT modify the generator in any way.
CAUTION
Start the generator and allow the engine to stabilize before connecting
electrical loads.
Connect electrical equipment in the off position, and then turn them on for
operation.
Turn electrical equipment off and disconnect before stopping the generator.
CAUTION
Improper treatment or use of the generator can damage it, shorten its life or
void the warranty.
Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and disconnect them from the
generator.
DO NOT use the generator if:
– Electrical output is lost
– Equipment sparks, smokes or emits flames
– Equipment vibrates excessively
Fuel Safety
DANGER
GASOLINE AND GASOLINE VAPORS ARE HIGHLY FLAMMABLE AND EXPLOSIVE.
Fire or explosion can cause severe burns or death.
Gasoline and gasoline vapors:
– Gasoline is highly flammable and explosive.
– Gasoline can cause a fire or explosion if ignited.
– Gasoline is a liquid fuel but it’s vapors can ignite.
– Gasoline is a skin irritant and needs to be cleaned up immediately if
spilled on skin or clothes.
– Gasoline has a distinctive odor, this will help detect potential leaks
quickly.
– Gasoline expands or contracts with ambient temperatures.
Never fill the gasoline tank to full capacity, as gasoline needs room to
expand when temperatures rise.
– In the case of any petroleum gasoline fire, flames should never be
extinguished unless the fuel supply valve can be turned OFF. By not doing so,
if a fire is extinguished and the supply of fuel is not turned OFF, an
explosion hazard could be created.
When adding or removing gasoline:
DO NOT light or smoke cigarettes.
Turn the generator off and let cool for at least two minutes before removing
the gasoline cap. Always loosen the cap slowly to relieve pressure in the
tank.
Only fill or drain gasoline outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator at the gas station. Always
use an approved container to transfer the fuel to the generator.
DO NOT overfill the gasoline tank.
Always keep gasoline away from sparks, open flames, pilot lights, heat and
other sources of ignition.
When starting the generator:
DO NOT attempt to start a damaged generator.
Always check that the gasoline cap, air filter, spark plug, fuel lines and
exhaust system are properly in place.
Always allow spilled gasoline to evaporate fully before attempting to start
the engine.
Always be certain that the generator is resting firmly on level ground.
When operating the generator:
DO NOT move or tip the generator during operation.
When transporting or servicing the generator:
Always check that the fuel valve is in the OFF position and the gasoline tank
is empty.
Disconnect the spark plug wire.
When storing the generator:
Store away from sparks, open flames, pilot lights, heat and other sources of
ignition.
Do not store generator or gasoline near furnaces, water heaters, or any other
appliances that produce heat or have automatic ignitions.
DANGER
NEVER place a gasoline container, gasoline tank, LPG cylinder or any
combustible material in the path of the exhaust stream during operation of the
engine.
WARNING
Never use a gasoline container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
Safety Labels**
These labels warn you of potential hazards that can cause serious injury. Read
them carefully.
If a label comes off or becomes hard to read, contact Technical Support Team
for possible replacement.
| LABEL| DESCRIPTION
---|---|---
A| | Safety Icons/CO
Danger
B| | Fuel
C| WARNING
DO NOT TOUCH!
Exhaust gases, muffler and engine components are extremely HOT and cause burns.
Operation of this equipment may create sparks that can start fires around dry
vegetation. A spark arrestor may be
required. The operator should contact local fire agencies for laws and
regulations relating to fire prevention requirements.
If installed, clean every 100 hours or every season.| Hot Surface
D| WWW.CHAMPIONPOWEREQUIPMENT.COM|
Dataplate
Safety Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL | MEANING |
---|---|
Read Operator’s Manual. To reduce the risk of injury, user must read and |
understand operator’s manual before using this product.
| Clearance. Keep all objects at least 5 feet (1.5m) from generator. Heat from
the muffler and exhaust gas can ignite combustible objects.
| Ground. Consult with local electrician to determine grounding requirements
before operation.
| Electric Shock. Failure to use in dry conditions and to observe safe
practices can result in electric shock. Improper connections to a building can
allow current to backfeed into utility lines, creating an electrocution
hazard. A transfer switch must be used when connecting to a building.
| Fire/Explosion. Fuel and its vapors are extremely flammable and explosive.
Fire or explosion can cause severe burns or death. Keep generator at least 5
feet (1.5m) from all objects to prevent combustion.
| Hot Surface. To reduce the risk of injury or damage, avoid contact with any
hot surface.
| Open Flame Alert. Fuel and its vapors are extremely flammable and explosive.
Keep fuel away from smoking, open flames, sparks, pilot lights, heat, and
other ignition sources.
| Wet Conditions Alert. Do not expose to rain or use in damp locations.
Operation Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product.
SYMBOL | MEANING |
---|---|
Start | |
On | |
Stop or Off | |
Neutral Bonded to Frame. Neutral circuit IS electrically connected to the |
frame/ground of the generator.
| Locking Receptacle
| Circuit Breaker Reset: Push
| Fuel/Gasoline Valve On/Off
| Choke
| Run
| Ground Terminal
Quick Start Label Symbols
Some of the following symbols may be used on this product. Please study them
and learn their meaning. Proper interpretation of these symbols will allow you
to more safely operate the product. Starting the Engine
DANGER
Move generator outside and far away from windows, doors and intake ventilation
covers.
-
Check oil level.
Recommended oil is 10W-30. -
Check gasoline level.
When adding gasoline, use a minimum octane rating of 87 and an ethanol content of 10% or less by volume. -
Turn the fuel valve to “ON” position.
-
Press ignition switch to the “ON” position.
-
Move choke lever to “CHOKE” position.
-
Pull the recoil cord.
-
Move the choke lever to “RUN” position.
-
Plug in desired device.
Stopping the Engine
- Turn off and unplug all connected electrical loads.
- Press the ignition switch to the “OFF” position.
- Turn the fuel valve to the “OFF” position.
Electric Start
See page 18 in “Operation” section.
CONTROLS AND FEATURES
Read this operator’s manual before operating your generator. Familiarize
yourself with the location and function of the controls and features. Save
this manual for future reference.
Generator![CHAMPION POWER EQUIPMENT 100814 7500W Electric Start Generator
-
FEATURES](https://manuals.plus/wp-content/uploads/2023/08/CHAMPION-POWER- EQUIPMENT-100814-7500W-Electric-Start-Generator-FEATURES.png)
- Gasoline Tank – 5.7 gal. (21.5 L)
- Choke – Used to start the engine.
- Fuel Valve – Used to turn fuel supply on and off to engine.
- Air Filter – Protects the engine by filtering dust and debris from the intake air.
- Recoil Starter – Used to manually start the engine.
- Never Flat Wheels – 9.5 in. (24.1 cm)
- Oil Fill Cap/Dipstick – Used to check and fill oil level.
- Battery – Provides 12V DC power the starting system.
- Ground Terminal – Consult an electrician for local grounding regulations.
- Control Panel – See “Control Panel” section.
- Folding Handle – Used to move unit by lifting and rolling on wheels. Do not use to lift or carry the unit.
Control Panel
- Ignition Switch – Used to START or STOP the generator.
- Intelligauge –Four mode digital meter for displaying voltage, frequency (hertz), run time, and total run time.
- Circuit Breakers (Push Reset) – Protects the generator against electrical overloads.
RECEPTACLES
A| | (4×) 120V AC, 20A GFCI (NEMA 5-20R)
May be used to supply electrical power for operation of 120 Volt AC, 20 Amp,
single phase, 60 Hz electrical loads.
---|---|---
B| | 120/240V AC, 30A Locking (NEMA L14-30R)
May be used to supply electrical power for operation of 120/240 Volt AC, 30
Amp, single phase, 60 Hz electrical loads.
C| | 120/240V AC, 50 Amp (NEMA 14-50R)
May be used to supply electrical power for operation of 120/240 Volt AC, 50
Amp, single phase, 60 Hz electrical loads.
Parts included
Accessories
Oil Funnel…………………………………………………..1
Engine Oil ……………………………………….1.2 qt. (1.1 L)
Assembly Parts
Wheels
9.5 in. (24.1 cm) Never Flat Wheel (A) …………………….2
Roll Pin (B) ………………………………………………2
Large R-clip (C) ………………………………………….2
Engine Vibration Mounts
Support Leg with Vibration Mounts (D) ……………………1
Flange Bolt (M8×16) (E) ………………………………….2
Flange Lock Nut (M8) (F) …………………………………2
Folding Handle
Handle (G) ……………………………………………….1
Short Pin (H) …………………………………………….2
Small R-clip (I) …………………………………………..2
Tools Needed
– Wrench/Socket Set (metric)
– Pliers
– Phillips Screwdriver
ASSEMBLY
Your generator requires some assembly. This unit ships from our factory
without oil. It must be properly serviced with fuel and oil before operation.
If you have any questions regarding the assembly of your generator, call our
Technical Support Team at
1-877-338-0999.
Please have your serial number and model number available.
Unpacking
- Set the shipping carton on a solid, flat surface.
- Remove everything from the carton except the generator.
- Carefully cut each corner of the box from top to bottom. Fold each side flat on the ground to provide a surface area to work with the generator.
Install the Wheel Kit
**CAUTION**
The wheel kit is not intended for over-the-road use.
- Before adding fuel and oil, tip the generator on it’s end.
- Slide the Roll Pin (B) through the Wheel (A) from the outside.
- Slide the Roll Pin through the mount point on the frame.
- Secure with the R-clip (C).
- Repeat to attach the second Wheel.
Install the Support Leg
- Attach the Support Leg (D) to the generator frame with FlangeBolts (E) and Flange Lock Nuts (F).
- Slowly tip the generator back down so that it rests on the Wheels and Support Leg.
Install the Handle
- Place the Handle (G) inside the mounting channel on the frame.
- Secure the Handle to the frame using an Short Pin (H).
- Place an R-clip (I) on the end of the Short Pin and fasten securely.
Connect the battery
- Remove the protective cover from the black (–) lead on the battery.
- Attach the black (–) lead to the (–) terminal on the battery with the bolt and secure with the nut.
Add Engine Oil
WARNING
DO NOT attempt to crank or start the engine before it has been properly filled
with the recommended type and amount of oil.
Damage to the generator as a result of failing to follow these instructions
will void your warranty.
NOTICE
The generator rotor has a sealed, pre-lubricated ball bearing that requires no
additional lubrication for the life of the bearing.
NOTICE
The recommended oil type for typical use is 10W-30 automotive oil. However,
using the listed conventional oils shown in the “Recommended Engine Oil Type”
chart may be used for typical use including the first 5 hours of the break-in
run time period of the engine.
If running generator in extreme temperatures, refer to the “Recommended Engine
Oil Type” chart.
- Place the generator on a flat, level surface.
- Remove oil fill cap/dipstick to add oil.
- Using a funnel, add up to 1.2 qt. (1.1 L) of oil (included) and replace oil fill cap/dipstick. DO NOT OVERFILL.
- Check engine oil level daily and add as needed.
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole.
When using the dipstick to check oil level, DO NOT screw in the dipstick while
checking.
NOTICE
Check oil level often during the break-in period. Refer to the Maintenance
section for recommended service intervals.
CAUTION
This engine is equipped with a low oil shut-off and will stop when the oil
level in the crankcase falls below the threshold level.
NOTICE
The first 5 hours of run time are the break-in period for the unit. During the
break in period stay at or below 50% of the running watt rating and vary the
load occasionally to allow stator windings to heat and cool. Adjusting the
load will also cause engine speed to vary slightly and help seat piston rings.
After the 5 hour break-in period, change the oil.
NOTICE
Synthetic oil may be used after the 5 hour initial break-in period. Using
synthetic oil does not decrease the recommended oil change interval. Full
synthetic 5W-30 oil will aid in starting in cold ambient < 41º F (5º C)
temperatures.
Add fuel
DANGER
Gasoline vapors are highly flammable and extremely explosive.
DO NOT light or smoke cigarettes. Fire or explosion can cause severe burns or
death.
Only fill or drain fuel outdoors in a well-ventilated area.
DO NOT pump gasoline directly into the generator. Use an approved container to
transfer the fuel to the generator.
Never use a gasoline container, gasoline tank, or any other fuel item that is
broken, cut, torn or damaged.
DO NOT overfill the gasoline tank. Always keep fuel away from sparks, open
flames, pilot lights, heat and other sources of ignition.
Use clean, fresh, regular unleaded gasoline with a minimum octane rating of 87
and an ethanol content of 10% or less by volume.
DO NOT mix oil with gasoline.
- Remove the gasoline cap.
- Slowly add gasoline to the tank. Tank is full when gasoline reaches red circle on screen. DO NOT OVERFILL. Gasoline can expand after filling. A minimum of ¼ in. (6.4 mm) of space left in the tank is required for gasoline expansion, although more than ¼ in. (6.4 mm) is recommended. Gasoline can be forced out of the tank as a result of expansion if overfilled, and can affect the stable running condition of the generator.
- Screw on the gasoline cap and wipe away any spilled fuel.
CAUTION
Use unleaded gasoline with a minimum octane rating of 87 and an ethanol
content of 10% or less by volume.
DO NOT light cigarettes or smoke when filling the tank.
DO NOT mix oil and gasoline.
DO NOT overfill the tank. Fill tank to approximately ¼ in.
(6.4 mm) below the top of the tank to allow for gasoline expansion.
DO NOT pump gasoline directly into the generator at the pump.
Use an approved fuel container to transfer the gasoline to the generator.
DO NOT fill tank indoors.
DO NOT fill tank when the engine is running or hot.
WARNING
Pouring gasoline too fast through the fuel screen may result in gasoline
splashing over the generator and operator while filling.
NOTICE
The generator engine works well with 10% or less ethanol blended gasoline.
When using ethanol-gasoline blends there are some issues worth noting:
– Ethanol-gasoline blends can absorb more water than gasoline alone.
– These ethanol blends can eventually separate, leaving water or a watery goo
in the tank, fuel valve and carburetor. The compromised gasoline can be drawn
into the carburetor and cause damage to the engine and/or create potential
hazards.
–If a fuel stabilizer is used, confirm that it is formulated to work with
ethanol-gasoline blends.
– Any damages or hazards caused by using ethanol blended gasoline higher than
10% by volume, improperly stored gasoline, and/or improperly formulated
stabilizers, are not covered by manufacturer’s warranty.
It is advisable to always shut off the gasoline supply and run the engine to
starvation after each use. See Storage instructions for extended non-use.
Grounding
Your generator must be properly connected to an appropriate ground to help
prevent electric shock.
WARNING
Failure to properly ground the generator can result in electric shock.
A ground terminal connected to the frame of the generator has been provided
(see Controls and Features for terminal location).
For remote grounding, connect a length of heavy gauge (12 AWG minimum) copper
wire between the generator ground terminal and a copper rod driven into the
ground. We strongly recommend that you consult with a qualified electrician to
ensure compliance with local electrical codes.
Neutral Floating
– Neutral circuit IS NOT electrically connected to the frame/ ground of the
generator.
– The generator (stator winding) is isolated from the frame and from the AC
receptacle ground pin.
– Electrical devices that require a grounded receptacle pin connection will
not function if the receptacle ground pin is not functional.
Neutral Bonded to Frame
– Neutral circuit IS electrically connected to the frame/ground of the
generator.
– The generator system ground connects lower frame crossmember below the
alternator. The system ground is connected to the AC neutral wire.
- See your Specifications section for specified type of grounding.
OPERATION
Generator Location
** WARNING
NEVER operate the generator inside any building, garage, basement, crawlspace,
shed, enclosure or compartment, including a generator compartment of a
recreational vehicle.
NEVER operate or start the generator in the back of an SUV, camper, trailer,
truck bed (regular sides, flat or other configuration), under staircases,
stairwells, next to walls or buildings or in any other location that will not
allow for adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather conditions such as rain
or snow. Using a generator in wet conditions could result in serious injury or
death due to electrocution.
In some state’s generators may be required to be registered with the local
utility company when used at construction sites and may be subject to
additional rules and regulations, consult your local municipal authority.
Generators should always be operated on a flat, level surface at all times
(even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of clearance from all
combustible material.
Generators must also have a minimum of 3 feet (91.4 cm) of air flow clearance
on all sides to allow for adequate performance cooling, maintenance and
servicing.
Always place the generator in a well-ventilated area. NEVER place the
generator near air intake vents or where exhaust fumes could be drawn into
occupied or confined spaces.
Always carefully consider wind and air currents when positioning generator.
Always allow generators to properly cool before transport or for storage
purposes.
Failure to follow proper safety precautions may result in personal injury,
damage to the generator and void the manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become hot. If adequate
cooling and breathing space are not supplied, or if the generator is blocked
or enclosed, temperatures can become extremely heated and may lead to fire.
WARNING
Do not expose to rain or use in damp locations.
Keep all objects a minimum of 5 feet (1.5m) away from the generator at all
times. Heat from the muffler surface and exhaust gas stream can ignite
combustible materials.
WARNING
If you must operate in rain or damp locations, DO NOT operate without proper
protection of the electrical components.
Use of a safety canopy that is fire retardant and will provide proper air
ventilation for the engine exhaust gas stream may be used.
Visit championpowerequipment.com or call
to find your Storm Shield cover.
Surge Protection
Electronic devices, including computers and many programmable appliances use
components that are designed to operate within a narrow voltage range and may
be affected by momentary voltage fluctuations. While there is no way to
prevent voltage fluctuations, you can take steps to protect sensitive
electronic equipment.
– Install UL1449, CSA-listed, plug-in surge suppressors on the outlets feeding
your sensitive equipment.
Surge suppressors come in single- or multi-outlet styles.
They’re designed to protect against virtually all short-duration voltage
fluctuations.
Starting the Engine**
- Make certain the generator is on a flat, level surface.
- Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on.
- Turn the gasoline fuel valve to the “ON” position.
Electric Start
-
Move the choke to the “CHOKE” position.
1a. For restarting a warm engine, move the choke to 75% of the “CHOKE” position. -
Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails to start within five seconds, release the switch and wait at least ten seconds before attempting to start the engine again. CAUTION
If the ignition switch is held down in the “START” position longer than 5 seconds it could damage the starter. -
Do not over-choke. As soon as engine starts, move the choke to the “RUN” position over a 2-5 second duration.
Manual Start
-
Push the ignition switch to the “ON” position.
-
Move the choke to the “CHOKE” position.
2a. For restarting a warm engine, move the choke to 75% of the “CHOKE” position. -
Pull the recoil cord slowly until resistance is felt and then pull rapidly.
-
Do not over-choke. As soon as engine starts, move the choke to the “RUN” position over a 2-5 second duration.
NOTICE
Keep choke in “CHOKE” position for only 1 pull of the recoil cord. After first
pull, move choke to “RUN” position for up to 3 pulls of the recoil cord. Too
much choke leads to spark plug fouling/engine flooding due to lack of incoming
air. This will cause the engine not to start.
NOTICE
For gasoline restarts with hot engine in hot ambient > 86°F (30°C), keep choke
in 75% of the “CHOKE” position for only 1 pull of the recoil cord. After first
pull, move choke to “RUN” position for up to 3 pulls of the recoil cord. Too
much choke leads to spark plug fouling/engine flooding due to lack of incoming
air. This will cause the engine not to start.
NOTICE
For gasoline starting in cold ambient temperature < 59°F (15°C), the choke
must be in 100% of the “CHOKE” position for manual start procedures. Do not
over-choke. As soon as engine starts, gradually move the choke lever to the
“RUN” position over a 2-5 second duration.
NOTICE
If the engine starts but does not run make certain that the generator is on a
flat, level surface. The engine is equipped with a low oil sensor that will
prevent the engine from running when the oil level falls below a critical
threshold.
Connecting Electrical Loads
Let the engine stabilize and warm up for a few minutes after starting.
Plug in and turn on the desired 120 or 240 (if applicable) Volt AC single
phase, 60 Hz electrical loads.
– DO NOT connect 3-phase loads to the generator.
– DO NOT overload the generator.
– Use only a high quality, insulated, compatible (3-wire or 4-wire) grounded
cord set rated equal to or greater (volts and amps) than the receptacle
plugging into.
WARNING
Always remember to plug your appliances directly into the generator and do not
plug the generator power cord into any electrical outlet or connect to the
circuit breaker panel in your home. Connecting a generator to your home’s
electric utility company’s power lines, or to another power source, called
‘backfeeding’ is a dangerous practice that is illegal in many states and
municipalities.
This action if done incorrectly could damage your generator, appliances and
could cause serious injury or death to you or a utility worker when attempting
to restore power during an outage occurrence in the neighborhood who may then
unexpectedly encounter high voltage on the utility line and suffer a fatal
shock.
Whether injuries occur or not, if installed incorrectly and not to applicable
laws and codes, you may be subject to fines or the utility company may
disconnect your home power should this practice be found in your home.
If the generator will be connected to a building electrical system, those
connections must isolate the generator power from the utility power. You are
responsible for ensuring your generator’s electricity does not backfeed into
the electric utility power lines. These connections must comply with all
applicable laws and codes – Consult your local utility company or a qualified
electrician to properly install this connection.
Do Not Overload Generator
Capacity
Follow these simple steps to calculate the running and starting watts
necessary for your purposes:
- Select the electrical devices you plan on running at the same time.
- Total the running watts of these items. This is the amount of power you need to keep your items running.
- Identify the highest starting wattage of all devices identified in step 1. Add this number to the number calculated in step 2Starting wattage is the extra burst of power needed to start some electric driven equipment. Following the steps listed under “Power Management” will guarantee that only one device will be starting at a time.
Power Management
Use the following formula to convert voltage and amperage towatts: Volts ×
Amps = Watts
To prolong the life of your generator and attached devices, follow these steps
to add electrical load:
- Start the generator with no electrical load attached.
- Allow the engine to run for several minutes to get up to temperature.
- Make sure all circuit breakers are set to the run position.
- Plug in and turn on the first item. It is best to attach the item with the largest load first.
- Allow the engine to stabilize.
- Plug in and turn on the next item.
- Allow the engine to stabilize.
- Repeat steps 5-6 for each additional item.
NOTICE
Never exceed the specified capacity when adding loads to the generator.
GFCI
Your generator is equipped with ground fault circuit interrupter (GFCI)
receptacles. In the event of a ground fault, a GFCI trips automatically to
stop the flow of electricity and prevent serious injury. The green indicator
light (A) on the receptacle will also turn off. Press the “RESET” (B) button
located on the front of the receptacle to restore flow of electricity. The
indicator light will also turn back on. GFCI does not protect against circuit
overloads.
To ensure proper operation of the GFCI duplex, perform this test monthly:
- With the generator running, plug a lamp into the GFCI receptacle. Turn the lamp on.
- Press the “TEST” (C) button located on the front of the receptacle to trip the device. This should immediately stop the flow of electricity and shut off the lamp. If the electricity is not stopped, do not use this receptacle until it has been serviced or replaced.
- Press the “RESET” button located on the front of the receptacle to restore the flow of electricity. If the indicator light does not come back on or if the GFCI cannot be reset then it must be replaced.
NOTICE
In any electrical application, some current will flow through the protective
ground conductor to the ground, this is called leakage current. It takes 4 mA
(0.004 A) and higher of leakage current from the hot wire to the ground to
cause a GFCI to trip.
On circuits protected by GFCI’s, leakage current can cause unnecessary and
intermittent tripping.
Some stationary motors, such as a bathroom vent fan, fluorescent lighting
fixtures or some refrigerators, may produce enough leakage to cause nuisance
tripping. To avoid nuisance tripping, a GFCI should not supply:
– Fluorescent or other types of electric-discharge lighting fixtures.
– Permanently installed electric motors, like air conditioners, furnaces or
refrigerators.
Stopping the Engine
- Turn off and unplug all connected electrical loads. Never start or stop the generator with electrical devices plugged in or turned on.
- Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generator.
- Press the ignition switch to the “OFF” position.
- Turn the fuel valve to the “OFF” position.
Important: Always ensure that the fuel valve and the ignition
switch are in the “OFF” position when the generator is not in use.
NOTICE
If the engine will not be used for a period of two (2) weeks or longer, please
see the Storage section for proper engine and fuel storage.
Operation at High Altitude
The density of air at high altitudes is lower than at sea level.
Engine power is reduced as the air mass and air-fuel ratio decrease. Engine
power and generator output will be reduced approximately 3½% for every 1000
ft. of elevation above sea level.At high altitudes increased exhaust emissions
can also result due to the increased enrichment of the air fuel ratio. Other
high altitudeissues can include hard starting, increased fuel consumption and
spark plug fouling.
To alleviate high altitude issues other than the natural power loss, CPE can
provide a high altitude carburetor main jet. The alternative main jet and
installation instructions can be obtained by contacting our Technical Support
Team. Installation instructions are also available in the Technical Bulletin
area of the CPE website.
The part number and recommended minimum altitude for the application of the
high altitude carburetor main jet is listed in the following table.
In order to select the correct high altitude main jet it is necessary to
identify the carburetor model. For this purpose, a code is stamped on the side
of the carburetor. Select the correct high altitude jet part number
corresponding to the carburetor code found on your particular carburetor.
Carb. Code | High Alt. Jet Part Number | Min. Altitude |
---|---|---|
Z950-1 | 100155681 | 3281 ft. |
(1000 m)
100062835| 6562 ft.
(2000 m)
WARNING
Operation using the alternative main jet at elevations lower than the
recommended minimum altitude can damage the engine. For operation at lower
elevations, the originally supplied standard main jet must be used. Operating
the engine with the wrong engine configuration at a given altitude may
increase its emissions and decrease fuel efficiency and performance.
MAINTENANCE
Make certain that the generator is kept clean and stored properly.
Only operate the unit on a flat, level surface in a clean, dry operating
environment. DO NOT expose the unit to extreme conditions, excessive dust,
dirt, moisture or corrosive vapors.
WARNING
Never operate a damaged or defective generator.
WARNiNG
Improper maintenance will void your warranty.
NOTICE
Maintenance, replacement, or repair of emission control devices and systems
may be performed by any non-road engine repair establishment or individual.
The owner/operator is responsible for all periodic maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating th e generator.
For service or parts assistance, contact our Technical Support Team at
1-877-338-0999.
Cleaning the Generator
** CAUTION**
DO NOT spray engine with water.
Water can enter the generator through the cooling slots and damage the
generator windings. It can also contaminate the fuel system.
- Use a damp cloth to clean exterior surfaces of the generator.
- Use a soft bristle brush to remove dirt and oil.
- Use an air compressor (25 PSI) to clear dirt and debris from the generator.
- Inspect all air vents and cooling slots to ensure that they are clean and unobstructed.
To prevent accidental starting, remove and ground the spark plug wire before performing any service.
Changing the Engine Oil
Change oil when the engine is warm. Refer to the oil specification to select
the proper grade for your operating environment.
-
Remove the oil drain bolt with a 12 mm socket (not included) and extension.
-
Allow the oil to drain completely into an appropriate container.
-
Replace the oil drain bolt.
-
Add oil according to Add Engine Oil in Assembly section.
DO NOT OVERFILL. Oil not included for routine maintenance. -
Dispose of used oil at an approved waste management facility.
NOTICE
Once oil has been added, a visual check should show oil about 1-2 threads from
running out of the fill hole. If using the dipstick to check oil level, DO NOT
screw in the dipstick while checking.
Cleaning and Adjusting the Spark Plug(s)
- Remove the spark plug cable from the spark plug.
- Use a spark plug socket tool (not included), or a 13/16 in. (21 mm) socket (not included) to remove the plug.
- Inspect the electrode on the plug. It must be clean and not worn to produce the spark required for ignition.
- Make certain the spark plug gap is 0.024-0.031 in. (0.6-0.8 mm).
- Refer to the spark plug types in Specifications when replacing the plug.
- Firmly re-install the plug.
- Attach the spark plug cable to the spark plug.
cleaning the Air filter
- Remove the snap-on cover holding the air filter to the assembly.
- Remove the foam element.
- Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth.
- Saturate in clean engine oil.
- Squeeze in a clean, absorbent cloth to remove all excess oil.
- Place the filter in the assembly.
- Reattach the air filter cover and snap in place.
cleaning the Spark Arrestor
- Allow the engine to cool completely before servicing the spark arrestor.
- Remove the two or three screws (varies by model) holding the cover plate which retains the spark arrestor to the muffler.
- Remove the spark arrestor screen.
- Carefully remove the carbon deposits from the spark arrestor screen with a wire brush.* See your model’s parts list for specified type of spark arrestor.
- Replace the spark arrestor if it is damaged.
- Position the spark arrestor on the muffler and attach with the screws removed in step 2.
CAUTION
Failure to clean the spark arrestor will result in degraded engine
performance.
NOICE
Federal and local laws and administrative requirements indicate when and where
spark arrestors are required. When ordered, spark arrestors are required for
operation of this generator in National Forest lands. In California, this
generator must not be used on any forest-covered land, brush-covered land, or
grass-covered land unless the engine is equipped with a spark arrestor.
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your warranty.
The air-fuel mixture is not adjustable. Tampering with the governor can damage
your generator and your electrical devices and will void your warranty.
Contact our Technical Support Team at
1-877-338-0999 for all other service
and/or adjustment needs.
Generator battery
Your generator is equipped with an automatic battery charging circuit that
charges the battery while the engine is running.
The battery will maintain a proper charge if the unit is used on a regular
basis (about once every two weeks). If it is used less frequently, the battery
should be connected to a trickle charger or battery maintainer (not included)
to keep the battery properly charged.
Maximum charging rate should not exceed 1.5 amps. Follow the instructions
included with the battery charger. The battery should be fully charged at
least once per month. If the battery is not able to start the engine, it can
be started by manually pulling the engine recoil cord. If the battery voltage
is extremely low, the charging circuit may not be able to re-charge the
battery. In this case, the battery must be connected to a standard automotive
style battery charger for re-charging before it can be used.
Disconnect the Battery
- Remove the protective cover from the black (–) battery lead.
- Disconnect the black (–) lead from the black (–) terminal on the battery and store the cap screw and nut.
- Repeat steps 1-2 for the red (+) battery lead.
- Store the battery in a cool, dry place.
Charge the Battery
For a generator equipped with batteries for electric starting, proper battery
maintenance and storage should be followed.
A trickle charger or battery maintainer should be used to charge the battery
while the generator is in storage. Maximum charging rate should not exceed 1.5
amps. Follow the instructions included with the trickle charger or battery
maintainer.
The battery should be fully charged at least once per month.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance schedule.
Service your generator more frequently when operating in adverse conditions.
Contact our Technical Support Team at
1-877-338-0999 to locate the nearest
CPE certified service dealer for your generator or engine maintenance needs.
EVERY 8 HOURS OR DAILY
— Check oil level
— Clean around air intake and muffler
FIRST 5 HOURS
— Change oil
EVERY 50 HOURS OR EVERY SEASON
— Clean air filter
— Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR EVERY SEASON
— Change oil
— Clean/adjust spark plug
— Check/adjust valve clearance
— Clean spark arrestor
— Clean fuel tank and filter
EVERY 250 HOURS
— Clean combustion chamber
EVERY 3 YEARS
— Replace fuel line
- To be performed by knowledgeable, experienced owners or CPE certified service centers.
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator during periods of
storage, the following precautions should be followed:
– When storing the generator make sure the ignition switch and fuel valve are
set to the “OFF” position.
Short Term Storage (up to 30 days)
Ethanol blended gasoline may gum up and clog the carburetor if the generator
is not run or carburetor drained within 4 weeks.
- Be sure all appliances are disconnected from the generator.
- Start the generator as instructed in Starting the Engine section.
- Turn the fuel valve to the “OFF” position.
- Let the engine run until fuel starvation has stopped the engine. This usually takes a few minutes.
- Move the ignition switch to the “OFF” position.
Mid Term Storage (30 days – 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life of up to 1 year
with the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
-
Be sure all appliances are disconnected from the generator.
-
Add a properly formulated fuel stabilizer to the gasoline tank.
-
Turn the fuel valve to the “ON” position.
-
Start and run the generator for 10 minutes so the treated gasoline cycles through the fuel system.
-
Option 1: Drain Gasoline from Carburetor
5a. Turn ignition switch to the “OFF” position and allow generator to cool completely before continuing.
5b. Turn the fuel valve to the “OFF”.
5c. Use the drain bolt on the carburetor to empty any excess gasoline from the carburetor into an appropriate container. Use a funnel (and appropriate hose if necessary) under the carburetor drain bolt to avoid spillage.5d. When gasoline stops flowing from the carburetor, replace and tighten the carburetor drain bolt and be sure to properly dispose of the drained gasoline according to local regulations or guidelines. -
Option 2: Run Dry
6a. With the generator running, turn the fuel valve to the “OFF” position and allow the generator to run until the engine stops from complete fuel starvation. This may take a few minutes.
6b. Turn ignition switch to the “OFF” position and allow generator to cool completely before continuing. -
Remove the spark plug cap and spark plug and pour about a tablespoon of oil into the cylinder.
-
Pull the recoil cord slowly to crank the engine to distribute the oil and lubricate the cylinder.
-
Install the spark plug and spark plug cap.
-
Clean the generator according to Cleaning the Generator.
-
Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank and carburetor must be completely
drained of gasoline.
- The generator is to be OFF and all appliances disconnected.
- Turn the fuel valve to the “ON” position.
- Use the drain bolt on the carburetor to empty any excess gasoline from the gasoline tank and carburetor into an appropriate container. Use a funnel (and appropriate hose if necessary) under the carburetor drain bolt to avoid spillage.
- When gasoline stops flowing from the carburetor, replace and tighten the carburetor drain bolt and be sure to properly dispose of the drained gasoline according to local regulations or guidelines.
- Turn the fuel valve to the “OFF” position.
- Follow steps 7-11 according to Mid Term Storage.
Removing from Storage
** NOTICE**
If the generator has been improperly stored for a period longer than 30 days
with ethanol blended gasoline in the gasoline tank and/or carburetor, all fuel
must be drained and the carburetor must be thoroughly cleaned of ethanol build
up. This process involves technically advanced tasks.
For assistance please call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all ethanol
blended gasoline prior to the generator being stored, follow the below steps
when removing from storage.
- Be sure the ignition switch is in the “OFF” position.
- Add gasoline to the generator according to Add Fuel.
- Turn the fuel valve to the “ON” position.
- After 5 minutes check the carburetor and air filter areas for any leaking gasoline. If any leaks are found, the carburetor will need to be disassembled and cleaned or replaced. If no gasoline leaks are found, turn the fuel valve to the “OFF” position.
- Check engine oil level and add clean, fresh oil if needed. See Oil Specifications for proper oil type.
- Check and clear air filter of any obstructions such as bugs or cobwebs. If necessary, clean air filter according to Cleaning the Air Filter.
- Start the generator according to Starting the Engine.
SPECIFICATIONS
Generator Specifications
Generator Model ……………………………………. 100814
Start Type ………………………………….. Electric, Manual
Watts (Starting/Running) ………………………… 9375/7500
AC Volts ……………………………………………..120/240
AC Amps @ 120 (Starting/Running)………………… 78.1/62.5
AC Amps @ 240 (Starting/Running) ………………….39.1/31.3
Frequency ……………………………………………..60 Hz
Phase ………………………………………………… Single
Gross Weight …………………………….. 218.4 lb. (99.1 kg)
Net Weight …………………………………..202.8 lb. (92 kg)
Length ……………………………………… 29.9 in. (76 cm)
Width …………………………………….. 27.2 in. (69.1 cm)
Height ………………………………………25.2 in. (64.1 cm)
Engine Specifications
Model …………………………………………………FH420
Displacement ………………………………………… 420 cc
Type …………………………………………… 4-Stroke OHV
Spark Plug
OEM Type ……………………………………………..F6RTC
Replacement Type ………………….NGK BPR6ES or equivalent
Gap …………………………… 0.024-0.031 in. (0.6-0.8 mm)
Valve
Intake Clearance …………….. 0.004-0.006 in. (0.10-0.15 mm)
Exhaust Clearance ………….. 0.006-0.008 in. (0.15-0.20 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is available at
www.championpowerequipment.com.
Oil Specifications
DO NOT OVERFILL.
Type ……………………………………..*See following chart
Capacity ………………………………………..1.2 qt. (1.1 L) NOTICE
Temperature will affect engine oil and engine performance.
Change the type of engine oil used based on temperature shown in the
“Recommended Engine Oil Type” table.
Fuel Specifications
Use regular unleaded gasoline with a minimum octane rating of 87 and an
ethanol content of 10% or less by volume. DO NOT USE E15 or E85. DO NOT
OVERFILL.
Gasoline Capacity …………………………….5.7 gal. (21.5 L)
Battery Specifications
Type ………………….. Rechargeable, Non-Spillable Lead Acid
Volts …………………………………………………….. 12
Capacity ……………………………………………….14 Ah
Temperature Specifications
Starting Temperature Range (°F/°C) ……….. 5 to 104/-15 to 40
NOTICE
An important message about temperature: Your product is designed and rated for
continuous operation at ambient temperatures up to 40°C (104°F). When your
product is needed it may be operated at temperatures ranging from 5°F (-15°C)
to 122°F (50°C) for short periods of time. If exposed to temperatures outside
this range during storage, it should be brought back within this range before
operation. In any event, the product must always be operated outdoors, in a
wellventilated area and away from doors, windows
and vents.
TROUBLESHOOTING
Problem | Cause | Solution |
---|---|---|
Generator will not start. | No fuel. | Add fuel. |
Faulty spark plug. | Replace spark plug. | |
Unit loaded during start up. | Remove load from unit. |
Generator will not start;
Generator starts but runs roughly.| Low oil level.| Fill crankcase to the
proper level.
Place generator on a flat, level surface.
Choke in the wrong position.| Adjust choke.
Spark plug wire loose.| Attach wire to spark plug.
enerator will not start electrically| Generator battery is dead.| Recharge
generator battery.
Battery switch is in the OFF position.| Turn battery switch to ON position.
Generator shuts down during operation.| Out of fuel.| Fill fuel tank.
Low oil level.| Fill crankcase to the proper level. Place
generator on a flat, level surface.
Generator cannot supply enough power or overheating.| Generator is
overloaded.| Review load and adjust. See “Connecting
Electrical Loads.”
Insufficient ventilation.| Check for air restriction. Move to a well
ventilated area.
No AC output.| Cable not properly connected.| Check all connections.
Connected device is defective.| Replace defective device.
Circuit breaker is open.| Reset circuit breaker
Faulty brush assembly.| Replace brush assembly (Service Center).
Faulty AVR (auto voltage regulator).| Replace AVR (Service Center).
Loose wiring.| Inspect and tighten wiring connections.
Other.| Contact the help line.
Generator gallops.| Engine governor defective.| Contact the help line.
Repeated circuit breaker tripping.| Overload.| Review load and adjust. See
“Connecting Electrical Loads.”
Faulty cords or device.| Check for damaged, bare or frayed wires.
Replace defective device.
For further technical support:
Technical Support Team
Toll Free 1-877-338-0999
support@championpowerequipment.com
WARRANTY* **
**
CHAMPION POWER EQUIPMENT
3 YEAR LIMITED WARRANTY
Warranty Qualifications
To register your product for warranty and FREE lifetime call center technical
support please visit: https://www.championpowerequipment.com/register
To complete registration you will need to include a copy of the purchase
receipt as proof of original purchase. Proof of purchase is required for
warranty service. Please register within ten (10) days from date of purchase.
Repair/Replacement Warranty
CPE warrants to the original purchaser that the mechanical and electrical
components will be free of defects in material and workmanship for a period of
three years (parts and labor) from the original date of purchase and 270 days
(parts and labor) for commercial and industrial use. Transportation charges on
product submitted for repair or replacement under this warranty are the sole
responsibility of the purchaser. This warranty only applies to the original
purchaser and is not transferable.
Do Not Return The Unit To The Place Of
Purchase
Contact CPE’s Technical Service and CPE will troubleshoot any issue via phone
or e-mail. If the problem is not corrected by this method, CPE will, at its
option, authorize evaluation, repair or replacement of the defective part or
component at a CPE Service Center. CPE will provide you with a case number for
warranty service. Please keep it for future reference. Repairs or replacements
without prior authorization, or at an unauthorized repair facility, will not
be covered by this warranty.
Warranty Exclusions
This warranty does not cover the following repairs and equipment:
Normal Wear
Products with mechanical and electrical components need periodic parts and
service to perform well. This warranty does not cover repair when normal use
has exhausted the life of a part or the equipment as a whole.
Installation, Use and Maintenance
This warranty will not apply to parts and/or labor if the product is deemed to
have been misused, neglected, involved in an accident, abused, loaded beyond
the product’s limits, modified, installed improperly or connected incorrectly
to any electrical component.
Normal maintenance is not covered by this warranty and is not required to be
performed at a facility or by a person authorized by CPE.
Other Exclusions
This warranty excludes:
– Cosmetic defects such as paint, decals, etc.
– Wear items such as filter elements, o-rings, etc.
– Accessory parts such as starting batteries, and storage covers.
– Failures due to acts of God and other force majeure events beyond the
manufacturer’s control.
– Problems caused by parts that are not original Champion Power Equipment
parts.
When applicable, this warranty does not apply to products used for prime power
in place of a utility.
Limits of implied Warranty and consequential Damage
Champion Power Equipment disclaims any obligation to cover any loss of time,
use of this product, freight, or any incidental or consequential claim by
anyone from using this product.
THIS WARRANTY AND THE ATTACHED U.S. EPA and/or CARB EMISSION CONTROL SYSTEM
WARRANTIES (WHEN APPLICABLE) ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.
A unit provided as an exchange will be subject to the warranty of the original
unit. The length of the warranty governing the exchanged unit will remain
calculated by reference to the purchase date of the original unit.
This warranty gives you certain legal rights which may change from state to
state or province to province. Your state or province may also have other
rights you may be entitled to that are not listed within this warranty.
contact information
Address
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670 USA
www.championpowerequipment.com
Customer Service
Toll Free: 1-877-338-0999
info@championpowerequipment.com
Fax no.: 1-562-236-9429
Technical Service
Toll Free: 1-877-338-0999
tech@championpowerequipment.com
EMERGENCY 24 HOUR SUPPORT:
1-562-204-1188
*Except as otherwise stipulated in any of the following enclosed Emission Control System Warranties (when applicable) for the Emission Control System: U.S. Environment Protection Agency (EPA) and/or California Air Resources Board (CARB). Whichever warranty applies for the longer period, either this 3 year limited warranty or the applicable Emission Control System Warranty, shall supersede the other.
CHAMPION POWER EQUIPMENT, INC. (CPE), THE UNITED STATES ENVIRONMENTAL
PROTECTION AGENCY (U.S. EPA) AND THE CALIFORNIA AIR RESOURCES BOARD (CARB)
EMISSION CONTROL SYSTEM WARRANTY
Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and
state of California Air Resources Board (CARB) Exhaust and Evaporative
emissions regulations.
YOUR WARRANTY RIGHTS AND OBLIGATIONS:
The US EPA, California Air Resources Board, and CPE are pleased to explain the
Federal and California Exhaust and Evaporative Emission Control Systems
Warranty on your 2022 small off-road engine (SORE) and engine powered
equipment. In California, new equipment that use small off-road engines (SORE)
must be designed, built and equipped to meet the State’s stringent anti-smog
standards.
CPE must warrant the exhaust and evaporative emission control system on your
small off-road engine (SORE) for the period listed below, provided there has
been no abuse, neglect, unapproved modification, or improper maintenance of
your equipment leading to the failure of the exhaust and evaporative emission
control systems.
Your evaporative emission control system may include parts such as:
carburetors, fuel tanks, fuel lines, (for liquid fuel and fuel vapors), fuel
caps, valves, canisters, filters, clamps, connectors, and other associated
components. Also included for your exhaust emission control system may be the
fuel-injection system, the ignition system, catalytic converter and other
exhaust emission related assemblies. Where a warrantable condition exits, CPE
will repair your small off-road engine (SORE) at no cost to you including
diagnosis, parts and labor.
MANUFACTURER’S WARRANTY COVERAGE:
This exhaust and evaporative emission control system is warranted for two
years. If any exhaust and evaporative, emission related part on your engine or
equipment is defective in, the part will be repaired or replaced by CPE.
OWNER WARRANTY RESPONSIBILITIES:
As the small off-road engine (SORE) owner, you are responsible for the
performance of the required maintenance listed in your Owner’s Manual. CPE
recommends that you retain all your receipts covering maintenance on your
small off-road engine (SORE), but CPE cannot deny warranty coverage solely for
the lack of receipts.
As the small off-road engine (SORE) owner, you should be aware that CPE may
deny you warranty coverage if your small off-road engine (SORE) or a part has
failed due to abuse, neglect, improper maintenance or unapproved
modifications.
You are responsible for presenting your small off-road engine to an Authorized
CPE distribution center, service center or alternate service outlet as
described in (3)(f) below or CPE dealer or CPE, Santa Fe Springs, Ca. as soon
as the problem exists. The warranty repairs shall be completed in a reasonable
amount of time, not to exceed 30 days.
If you have any questions regarding your warranty coverage, you should
contact:
Champion Power Equipment, Inc.
Customer Service
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
tech@championpowerequipment.com
EXHAUST AND EVAPORATIVE EMISSION CONTROL SYSTEM WARRANTY
The following are specific provisions relative to your Exhaust and
Evaporative Emission Control System (ECS) Warranty Coverage.
-
APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (SORE) (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
-
GENERAL EMISSIONS WARRANTY COVERAGE
CPE warrants to the original, end-use purchaser of the new engine or equipment and to each subsequent purchaser that each of its small off-road engines (SORE) is:
2a. Designed, built and equipped to conform to U.S. EPA emissions standards for spark-ignited engines at or below 19 kilowatts and all applicable regulations adopted by the California Air Resources Board and
2b. Free from defects in materials and workmanship that cause the failure of a warranted part to be identical in all material respects to the part as described in the engine manufacturer’s application for certification for a period of two years. -
THE WARRANTY ON EXHAUST AND EVAPORATIVE EMISSION-RELATED PARTS WILL BE INTERPRETED AS FOLLOWS:
3a. Any warranted part that is not scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the ECS Warranty Period. If any such part fails during the ECS Warranty Period, it shall be repaired or replaced by CPE according to Subsection “d” below. Any such part repaired or replaced under the ECS Warranty shall be warranted for any remainder of the ECS Warranty Period.
3b. Any warranted, exhaust and evaporative emissions-related part which is scheduled only for regular inspection as specified in the Owner’s Manual shall be warranted for the ECS Warranty Period. A statement in such written instructions to the effect of “repair or replace as necessary”, shall not reduce the ECS Warranty Period. Any such part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period.
3c. Any warranted, exhaust and evaporative emissions-related part which is scheduled for replacement as required maintenance in the Owner’s Manual shall be warranted for the period of time prior to the first scheduled replacement point for that part. If the part fails prior to the first scheduled replacement, the part shall be repaired or replaced by CPE according to Subsection “d” below. Any such exhaust and evaporative emissions-related part repaired or replaced under the ECS Warranty, shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions-related part.
3d. Repair or replacement of any warranted, exhaust and evaporative emissions- related part under this ECS Warranty shall be performed at no charge to the owner at a CPE Authorized Service Outlet.
3e. The owner shall not be charged for diagnostic labor which leads to the determination that a part covered by the ECS Warranty is in fact defective, provided that such diagnostic work is performed at a CPE Authorized Service Outlet.
3f. CPE shall pay for covered exhaust and evaporative emissions warranty repairs at non-authorized service outlets under the following circumstances:
i. The service is required in a population center with a population over 100,000 according to U.S. Census 2000 without a CPE Authorized Service Outlet AND
ii. The service is required more than 100 miles from a CPE Authorized Service Outlet. The 100 mile limitation does not apply in the following states: Alaska, Arizona, Colorado, Hawaii, Idaho, Montana, Nebraska, Nevada, New Mexico, Oregon, Texas, Utah and Wyoming.
3g. CPE shall be liable for damages to other original engine components or approved modifications proximately caused by a failure under warranty of an emission-related part covered by the ECS Warranty.
3h. Throughout the ECS Warranty Period, CPE shall maintain a supply of warranted exhaust and evaporative emission-related parts sufficient to meet the expected demand for such exhaust and evaporative emission-related parts.
3i. Any CPE Authorized and approved exhaust and evaporative emission-related replacement part may be used in the performance of any ECS Warranty maintenance or repair and will be provided without charge to the owner. Such use shall not reduce CPE’s warranty obligation.
3j. Unapproved add-on or modified parts may not be used to modify or repair a CPE engine. Such use voids this ECS Warranty and shall be sufficient grounds for disallowing an ECS Warranty claim. CPE shall not be liable hereunder for failures of any warranted parts of a CPE engine caused by the use of such an unapproved add-on or modified part.
EMISSION-RELATED PARTS INCLUDE THE FOLLOWING: (using those portions of the list applicable to the engine)
Systems covered by this warranty | Parts Description |
---|---|
Fuel Metering System | Carburetor and internal parts (and/or pressure regulator |
or fuel injection system), Air/fuel ratio feedback and control system, Cold
start enrichment system.
Air Induction System| Controlled hot air intake system, Intake manifold, Air
filter.
Ignition System| Spark plug, Magneto or electronic ignition system, Spark
advance/retard system.
Exhaust Gas Recirculation (EGR)
System| EGR valve body, and carburetor spacer if applicable, EGR rate feedback
and control system.
Air Injection System| Air pump or pulse valve, Valves affecting distribution
of flow, Distribution manifold.
Catalyst or Thermal Reactor
System| Catalytic Converter, Thermal Reactor, Exhaust Manifold.
Particulate Controls| Traps, Filters, Precipitators, and any other device used
to capture particulate emissions.
Miscellaneous items used in Above Systems| Vacuum, Temperature, and time
sensitive valves and switches, Electronic Controls, Hoses, Belts, Connectors,
and Assemblies.
Evaporative Controls| Fuel Tank, Fuel Cap, Fuel Lines (for liquid fuel and
fuel vapors), Fuel Line Fittings, Clamps, Pressure Relief Valves, Control
Valves, Control Solenoids, Electronic Controls, Vacuum Control Diaphragms,
Control Cables, Control Linkages, Purge Valves, Gaskets, Liquid/Vapor
Separator, Carbon Canister,
Canister Mounting Brackets, Carburetor Purge Port Connector.
TO OBTAIN WARRANTY SERVICE:
You must take your CPE engine or the product on which it is installed, along
with your warranty registration card or other proof of original purchase date,
at your expense, to any Champion Power Equipment dealer who is authorized by
Champion Power Equipment, Inc. to sell and service that CPE product during his
normal business hours. Alternate service locations defined in Section (3)(f)
above must be approved by CPE prior to service. Claims for repair or
adjustment found to be caused solely by defects in material or workmanship
will not be denied because the engine was not properly maintained and used.
If you have any questions regarding your warranty rights and responsibilities,
or to obtain warranty service, please write or call Customer Service at
Champion Power Equipment, Inc.
Champion Power Equipment, Inc.
12039 Smith Ave.
Santa Fe Springs, CA 90670
1-877-338-0999
Attn.: Customer Service
tech@championpowerequipment.com
REV 20220630
Champion Power Equipment, Inc., Santa Fe Springs, CA USA
Documents / Resources
|
CHAMPION POWER EQUIPMENT 100814 7500W Electric Start
Generator
[pdf] User Manual
100814 7500W Electric Start Generator, 100814, 7500W Electric Start Generator,
Electric Start Generator, Start Generator, Generator
---|---