Moes BE09-220509 Human Presence Sensor Instruction Manual

June 12, 2024
MOES

Moes logo Human presence sensor
ZigBee 3.0
Instruction ManualMoes BE09-220509 Human Presence
SensorMoes BE09-220509 Human Presence Sensor - icom
2

BE09-220509 Human Presence Sensor

  • Bitte scannen Sie den QR code, um das deutsche Handbuch, das Installationsvideo und die Funktionseinführung zu erhalten
  • Escanee el codigo QR para obtener el manual en español, el video de instalación y la introducción de la function
  • Veuillez scanner le code QR pour obtenir le manuel en français, la video d’installation et l’introduction des functions
  • Scan the QR code to get the guide in Russian, installation video and description functions
  • Leia o código QR para obter o manual em português, o vídeo de instalação e a introdução das funções

| Moes BE09-220509 Human Presence Sensor - QR code 1
---|---
https://drive.google.com/drive/folders/1eiFr7NiWVrpEec9UI3JL9nqmTboIPA53?usp=sharing| https://pan.baidu.com/s/1bOJWC4T9IMFijwQerJgc2w?pwd=b5n9

Product introduction

The human presence sensor has the function of human presence, human static, human micro motion and human motion detection, which can detect the presence or absence of people in the area. It can also accurately detect the static state such as personnel sleeping. The sensor can output sensing results through wireless (WiFi, ZigBee, Bluetooth, 4G) or wired (RS485, RS232, dry contact, wet contact) to provide sensing and scene intermodal functions for IOT fields such as smart home, smart hotel, smart office, smart elevator, security monitoring, etc.Moes BE09-220509 Human Presence Sensor - fig
1

Entering the Network Configuration Mode

  1. Power on the deviceMoes BE09-220509 Human Presence Sensor - fig 2
  2. Long press the button until blue indicator light flash quickly, then sensor enter network configuration state.
  3. When network configuration, make sure the device as close as possible to the Gateway.
  4. Open My Home Page in TuyaSmart App, click to enter the added gatedway, select to add sub-device. Then follow the operation according to the App hint.
  5. If network configuration fail, repeat to long press the device button until blue light flash quickly. Repeat above operation.

Installation instruction

a. Select a suitable installation position on the ceiling according to the range and shape of the area to be tested to ensure that the detection area can be effectively covered.
b. The diameter of the equipment panel is 93mm, the rear rectangular part is 65x70mm, and a circular hole with a diameter of 80mm can be opened on the coiling. c. Clamp the power and signal wires on the equipment (clamp the wires gently, otherwise the wires are easy to be clamped off and introduced inlo the ceiling opening).
d. Clip the equipment into the ceiling hole to complete the installation.

Detection area instruction

  1. Device detection area:
    presence delect diameter: 2-6 m.
    motion and micro motion detecct diameter: 8-12 m.Moes BE09-220509 Human
Presence Sensor - fig 4

Important hint: the detectable distance is related to many factors such as installation environment, human volume, relative angle and micro motion / movement speed. The above parameters are only the test results of our testers for reference only. In different environment, the user shall be subject to the actual measurement.

Use instruction

In order to better adapt the equipment to the scene and environment and realize the best detection function and performance index simultaneously, the three main parameters of “detection distance”, “sensitivity” and “delay time” can be adjusted:

  1. Detection distance: up to 9.5 m, default to 6 m. If the detection distance is too far, unnecessary target interference is easy to occur in the scane with low installation height and narrow installation height (secondary multiple reflection, L-shaped right angle reflection and other effects lead to the detection of targets that do not need to be detected or affect parameter indicators);
  2. Sensitivity: any number from 0 to 9 can be set. 9 represents the highest sensitivity and O represents the lowest. The default sensitivity is 7. The smaller the sensitivity, the greater the target micro motion or breathing amplitude and the closer the distance can be detected. The greater the sensitivity, if there are weaker and wider range of interferents, it is easier to make false alarm.
  3. Delay time: the delay time has two parameters:
    ⑴ The parameter configures the confirmation time after “largel delecled”. Configuring the best parameter value can greatly reduce the false alarm rate. Although the larger the value is, the more reliable it is, when the real target appears, the equipment needs a longer time to report that the target has been detected.
    ⑵ The parameter configures the confirmation time after the “targel disappears” (the delay time generally understood by the user). The larger the configured parameter value, the easier it is to reduce the false alarm rate caused by the accidental disappearance of the target. Although the larger the value, the more reliable it is, after the target really disappears, the equipment needs a longer lime to report that the target has disappeared.

Common problems and precautions

  1. Detect someone when no one there: it is recommended to set the detection distance short, high and low sensitivity to investigate the cause and find the interferences in the environment. Avoid the interference by limiting the farthest detection distance and installation method.
  2. Cannot detect when humman present: people need to be in the effective detection area; if sitting still, they need the body parts with relative movement (such as breathing movement) to be inclined or facing the equipment and then be detected.
  3. It is suggested that the target disappearance confirmation time (delay time) should not be too small. The default time is 15 seconds. If it is smaller, the target may disappear with a certain probability due to accidental respiratory pause, resulting in missing report.
  4. In the scenes with low and narrow installation height, such as bathroom, washing room and kitchen, it is recommended to set the detection distance smaller than the installation height and have high and low sensitivity.

Technical parameter

Product name Human presence sensor
Wireless Technology Zigbee
Work voltage DC 12V
Work current <70mA
Work temperature -20℃~+70℃
Sensitivity 0-9 (Default 7)
Detect distance 0.3–9m (Default distance 6 m)
Delay time 1.target detection confirmation time: 0-10s.

2.target disappearance delay time: 0.5s-25min.
It is recommended not to be less than 15 seconds. If too small, easy to miss.
Light sense| 0–2000Lux
Installation mode| Ceiling
Product size| 93×30

Packing List

  • Human presence sensor x1
  • User manual x1

Warranty Certificate Toxic or Hazardous Substances or Elements of this Product

Component name Toxic or Hazardous Substances or Elements
Lead (Pb) Mercury (Hg)
(Cr(VI)) Polybrominated biphenyls (PBB)

(PBDE)
LED| 0| 0| 0| 0| 0| 0
PCB| X| 0| 0| 0| 0| 0
Cover and other components| X| 0| 0| 0| 0| 0

This table complies with SJ/T 11364.
O: indicates that the toxic or hazardous substance amount contained in all homogeneous materials of a component does not exceed that stipulated in GB/T 26572.
X: indicates that the toxic or hazardous substance amount contained in at least one of the homogeneous materials of a component exceeds that stipulated in GB/T 26572.

SERVICE

  1. During the free warranty period, if the product breaks down during normal use, we will offer free maintenance for the product.
  2. Natural disasters/man-made equipment failures, disassembly and repair without the permission of our company, no warranty card, products beyond the free warranty period, etc., are not within the scope of free warranty
  3. Any commitment (oral or written) made by the third party (including the dealer/service provider) to the user beyond the warranty scope shall be executed by the third party
  4. Please keep this warranty card to ensure your rights
  5. Our company may update or change the products without notice. Please refer to the official website for the updates.

RECYCLING INFORMATION

All products marked with the symbol for separate collection of waste electrical and electronic equipment (WEEE Directive 2012/19 / EU) must be disposed of separately from unsorted municipal waste. To protect your health and the environment, this equipment must be disposed of at designated collection points for electrical and electronic equipment designated by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences for the environment and human health. To find out where these collection points are and how they work, contact the installer or your local authority.

WARRANTY CARD

Product Information
Product Name: ………………………………….
Product Type: ……………………………………
Purchase Date: ……………………………………..
Warranty Period: …………………………………..
Dealer Information: ………………………………..
Customer’s Name: …………………………………
Customer Phone: ……………………………………..
Customer Address: ……………………………….
Maintenance Records

Failure date Cause Of Issue Fault Content Principal

Thank you for your support and purchase at we Moes, we are always here for your complete satisfaction, just feel free to share your great shopping experience with us. If you have any other need, please do not hesitate to contact us first, we will try to meet your demand.

@moessmart
@moes_smart
MOES.Official
@moes_smart
@moes_smart
www.moes.net

Moes logo WENZHOU NOVA NEW ENERGY CO.,LTD
Address: Power Science and Technology Innovation Center,
NO.238, Wei 11 Road, Yueqing Economic Development Zone,
Yueqing, Zhejiang, China
Tel:+86-577-57186815
Email: [email protected]
AMZLAB GmbH
Laubenhof 23, 45326 Essen
Made In China
BE09

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MOES User Manuals

Related Manuals