Air Live Smart In Wall Dimmer User Manual
- June 7, 2024
- Air Live
Table of Contents
**Air Live Smart In Wall Dimmer User Manual
**
Overview
SD-101 is a security enabled wireless dimmer, based on Z-Wave Plus technology. Z-Wave PlusTM enabled devices displaying the Z-Wave PlusTM logo can also be used with itregardless of the manufacturer, and can also be used in other manufacturer’s Z-WaveTM enabled networks. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb. This dimmer is a transceiver which is a security enabled device which based on Z-Wave Plus technology, and it is fully compatible with any Z-WaveTM enabled network. Since SD-101 supports Security Command Class, it can learn with a Secured enabled controller to fully utilize the device. Its functionality and supported command classes is identical when included as a secure and non-secure device.
Built-in High Breaking Capacity current fuse protection. Rating: 2A 250V
Built-in Thermal Cut-off Fuses protection. Rated Temperature: 125 °C; Rating:
2A 250V.
IMPORTANT :
Please make sure the switches are wired in the same AC power line loop.
Fig 1. Assembling & Wiring
Warning: Do not use Non-Dimmable LED lamps.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button (also an include button) with LED indicator below which is used to dim on and off or carries out inclusion, exclusion, reset or association. When first power applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the dimmer does not have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of explorer frame will be emitted once every several seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the dimmer.
The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to Add/Remove/associate devices.
Function | Description | Annotation |
---|---|---|
No node ID | The Z-Wave Controller does not allocate a |
node ID to the Switch.
| LED 2-second on, 2-second off
Add (Inclusion)| Put your Z-Wave controller into inclusion mode by following
the instructions provided by the controller manufacturer.|
Pressing Include button of SD-101 three times within 2 seconds will enter
inclusion mode.
Remove (Exclusion)| Put your Z-Wave controller into exclusion mode by
following the instructions provided by the controller manufacturer.|
Pressing Include button of SD-101 three times within 2 seconds will enter
exclusion mode.
Node ID has been excluded.| 0.5s On, 0.5s Off (Enter auto inclusion)
Reset| Pressing Include button of SD-101 three times within 2 seconds will
enter inclusion mode.| Use this procedure only in the event that the primary
controller is lost or otherwise inoperable.
Within 1 second, press Include button of SD-101 again for 5 seconds.
IDs are excluded.| 0.5s On, 0.5s Off (Enter auto inclusion)
Association| The SD-101 is an always listening Z-Wave device, so associations
may be added or removed by a controller at any time. Or If your controller
requires to have the SD-101 send a ‘node information frame’ or NIF for
associations, then pressing the On/Off button three times within 2 seconds
will cause the SD-101 to send its NIF.|
There are two groups for the dimmer.|
Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a
node ID allocated by Z-Wave Controller means exclusion. Failed or success in
including/excluding the node ID can be viewed from the Z-Wave Controller.
LED Indication
To distinguish what mode the switch is in, view from the LED for identification.
State Type | LED Indication |
---|---|
Normal | Whenever we switch On and off of the SD-101 by On/Off button or RF |
command, the LED will lights up when switch on; whereas LED off when switch
off.
No node ID| Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals. By
pressing On/Off button, it will stop flashing temporarily.
Learning| When SD-101 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
Manual dim level control
To manually switch on the light, press and release the On/Off button or S1/S2 shortly when the light is off. The light will dim from off to the level which was set before switch off. To manually switch off the light, press and release the On/Off button or S1/S2 shortly when the light is on. To adjust the dim level, press and hold the On/Off button or S1/S2 until the desired dim level is achieved, then release.
Programming
Basic Command Class / Multilevel Switch Command Class
The dimmer will respond to BASIC and MULTILEVEL SWITCH commands that are part of the Z-Wave system. If SD-101 is included as a secured node, it will only response to the security encapsulation command of BASIC and MULTILEVEL SWITCH.
BASIC_GET / MULTILEVEL_SWITCH_GET
Upon receipt of the following commands from a Z-Wave Controller, the Switch will report its dimmer state to the node inquired.
Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0]
Report ON: [Command Class Basic, Basic Report, Value = 1~99]
Multilevel Switch Get Command:[Command Class Multilevel Switch, Multilevel
Switch Get]
Multilevel Switch Report Command: Report OFF: [Command Class Multilevel
Switch, Multilevel Switch Report, Value=0] Report ON: [Command Class
Multilevel Switch, Multilevel Switch Report, Value =1~99]
BASIC_SET / MULTILEVEL_SWITCH _SET
Upon receipt of the following commands from a Z-Wave Controller, the load attached to the dimmer will turn on or off.
[Command Class Basic, Basic Set, Value = 0] : the load attached to the dimmer turns off.
[Command Class Basic, Basic Set, Value = 1~99] : the attached load dim on
as the level.
[Command Class Multilevel Switch, Multilevel Switch Set, Value=0, Duration
= 0~255] : the load attached to the dimmer turns off.
[Command Class Multilevel Switch, Multilevel Switch Set, Value =1~99,
Duration = 0~255] : the attached load dim on as the level.
Z-Wave’s Groups
The Switch can be set to send reports to associated Z-Wave devices. It supports one association group with five nodes support for grouping 1. For group 1, the dimmer will report MULTILEVEL_SWITCH_REPORT, ALARM_REPORT and DEVICE_RESETLOCALLY NOTIFICATION.
Grouping 1 Lifeline (Maximum 5 nodes)
Device reset locally notification
When SD-101 is reset manually, it will send a DEVICE_RESETLOCALLY NOTIFICATION to the nodes of group 1.
On/Off Event Report
When “on” or “off ” state has been changed, it will send Multilevel Switch Report to the nodes of Grouping 1.
Multilevel Switch Report
ON: [Command Class Multilevel Switch, Multilevel Switch Report, Value =1~99]
OFF: [Command Class Multilevel Switch, Multilevel Switch Report, Value =0(0x00)]
Overload alarm report
When SD-101 detects the Overload, it will send Alarm Report to Group 1 nodes. After detecting overload state and sending this alarm report, SD-101 will turn off the dimmer automatically and lockout the On/Off button and S1/S2. The only thing to do is unplug SD-101 and reduce the load. Then re-power on SD-101 and it will work again. The content of Alarm Report.
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF]
Grouping 2 Control_Key1 : (Maximum 5 nodes)
When the On/Off status changes or the dim level is achieved manually, it will
send
BASIC_SET command to group 2 nodes to make them unanimous.
Dimmer Off : [Command Class Basic, Basic Set, Value = 0]
Dimmer On : [Command Class Basic, Basic Set, Value = 1~99]
Z-Wave’s Configuration
Configuration Parameter| Function| Size (Byte)| Value|
Unit| Default| Description
---|---|---|---|---|---|---
1| Dimmer Level Report mode| 1| 0-1| | 1| 0 : Disable
1 : Enable
2| LED indication mode| 1| 1-3| | 1|
- Show dimmer state
- Show night mode
- One flash mode
3| External switch type| 1| 1-3| | 1|
- One switch mode
- Two switch mode
- Up/Down switch mode
4| Restore dimmer state| 1| 0-2| | 1| 0 : Dimmer off
1:Last dimmer state
2 : Dimmer on
Dimmer level report mode
Whenever dimmer on/off state changes, it will send MULTILEVEL_SWITCH_REPORT to the nodes of group1. The default setting is Enable the function.
LED indication mode
Show dimmer State :
When dimmer is on, LED is on. When dimmer is off, LED is off. The default setting is Show dimmer State.
Show Night mode :
When dimmer is on, LED is off. When dimmer is off, LED is on
One flash mode
When dimmer on/off state changes, LED will light on one second and then off
External switch type:
One switch mode
Only S1 can dim up the light bulb to brightest level, then dim down to darkest level, and so on…
Two switch mode
S1 and S2 can dim up the light bulb to brightest level, then dim down to darkest level, and so on…
Up/Down switch mode
S1 can only dim up the light bulb to brightest level, and S2 can only dim down to Off.
Restore dimmer state :
Whenever the AC power returns from lost, SD-101 will restore the switch state which could be Dimmer off、Last dimmer state、Dimmer on. The default setting is Last dimmer state.
Firmware update over the air (OTA)
SD-101 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed.
Command Classes
The Switch supports Command Classes including…
-
- COMMAND_CLASS_ZWAVEPLUS_INFO
-
- COMMAND_CLASS_VERSION_V2
-
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
-
- COMMAND_CLASS_SECURITY
-
- COMMAND_CLASS_DEVICE_RESET_LOCALLY
-
- COMMAND_CLASS_ASSOCIATION_V2
-
- COMMAND_CLASS_ASSOCIATION_GRP_INFO
-
- COMMAND_CLASS_POWERLEVEL
-
- COMMAND_CLASS_BASIC
-
- COMMAND_CLASS_SWITCH_MULTILEVEL_V2
-
- COMMAND_CLASS_CONFIGURATION
-
- COMMAND_CLASS_ALARM
-
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
-
- COMMAND_CLASS_SCENE_ACTIVATION
-
- COMMAND_CLASS_SCENE_ACTUATOR_CONF
Troubleshooting
Symptom | Cause of Failure | Recommendation |
---|---|---|
The dimmer does not work and LED off |
- The dimmer does not connect the electrical wire properly
- The dimmer break down
|
- Check power connections
- Don’t open up the dimmer and send it for repair.
The dimmer LED| Check if the load connected to| Set the ON/OFF switch of the
illuminating, but cannot control the ON/OFF state of the load attached| the
dimmer has its own ON/OFF switch| load attached to ON
The dimmer LED illuminating, but the Detector cannot control the Switch|
- Not carry out association
- Same frequency interference
|
- Carry out association
- Wait for a while to re-try
Specification
Input Rating:(Operating Voltage) | 100-240Vac / 50Hz-60Hz |
---|---|
Input Rating:(Operating Current) | 0.01~1A ; (Maximum: 1A) |
Output Rating: Maximum Load (Current) | Maximum: 0.9A (100-240Vac) |
Output Rating: Maximum Load (watts)(230V) | 200W (13W x 15 pieces) (Dimmable |
LED bulbs)
(230Vac)
Output Rating: Maximum Load (watts)(120V)| 100W (13W x 15 pieces) (Dimmable LED bulbs)
(120Vac)
Output Rating: Maximum Dimmable LED bulbs| Maximum: 15 pieces (Dimmable LED
bulbs)
Operating Temperature| 0°C ~ 40°C
Frequency Range| 868.40MHz & 869.85MHz/ EU (SD-101-EU);
908.4MHz & 916.0MHz/ USA (SD-101-US);
RF Maximum Power| +5dBm
Transmission Range| Minimum 40 m in door 100m outdoor line of sight
Modulation Type| FSK (Frequency-Shift Keying)
Warning: Do not use Non-Dimmable LED lamps.
DANGER Danger of electrocution!
All works on the device may be performed only by a qualified and licensed electrician. Observe national regulations.
Any works introducing changes into the configuration must be always performed with disconnected voltage.
Choosing a Suitable Location
- Do not locate the Module facing direct sunlight, humid or dusty place.
- The suitable ambient temperature for the Module is 0°C~40°C.
- Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
- After putting it into use, the body of Module will become a little bit hot of which phenomenon is normal.
IMPORTANT
Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation. Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods. Before proceeding with the installation, turn off the power to the lighting circuit at the circuit breaker or fuse box to avoid electrical shock.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate this
equipment. This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
Warning
- Plug out to disconnect from power supply; Do not plug in line.
- Do not exceed the max rating.
- Do not use Non-Dimmable LED lamps.
Disposal
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
OvisLink Corp.,http://www.airlive.com/
TEL: +886 2 2218 6888
FAX: +886 2 2918 6988
References
- wifi6 MESH Router|AirLive|Managed Switch|5G|Your best choice of Smart Network Solution
- wifi6 MESH Router|AirLive|Managed Switch|5G|Your best choice of Smart Network Solution
Read User Manual Online (PDF format)