FX Luminaire FX-264 Down Light Instruction Manual

June 12, 2024
FX Luminaire

FX Luminaire FX-264 Down Light

INSTALLATION

  1. Change beam angle lenses and color filters by removing and replacing existing components (optional). *¾” (5 mm) Alan wrench.
  2. Determine the path of the wire; drill a hole if necessary.
  3. Affix the mounting bracket to the surface.
  4. Attach the fixture to the bracket.
  5. Use a voltmeter to ensure 11 to 15V at the fixture.
  6. Connect wiring with a waterproof connector.

CIRCUITING GUIDELINES

Recommandations pour le raccordement

TRANSFORMERS

  • Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
  • Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drops by installing the transformers as close to the fixtures as possible.
  • Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

INJURY TO PERSON:

  • Turn off/unplug it and allow it to cool before replacing the lamp.
  • The lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch the hot lens, guard, or enclosure.
  • Keep lamps away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage the lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield
  • WARNING – Risk of Electric Shock
  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for the secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum of 6″ (152 mm) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or a fitting.
  • This product contains . light source of energy efficiency class G.
  • LANDSCAPE & ARCHITECTURAL LIGHTING | Learn more. Visitfxl.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FX Luminaire User Manuals

Related Manuals