FX Luminaire FX-264 Down Light Instruction Manual
- June 12, 2024
- FX Luminaire
Table of Contents
FX Luminaire FX-264 Down Light
INSTALLATION
- Change beam angle lenses and color filters by removing and replacing existing components (optional). *¾” (5 mm) Alan wrench.
- Determine the path of the wire; drill a hole if necessary.
- Affix the mounting bracket to the surface.
- Attach the fixture to the bracket.
- Use a voltmeter to ensure 11 to 15V at the fixture.
- Connect wiring with a waterproof connector.
CIRCUITING GUIDELINES
Recommandations pour le raccordement
TRANSFORMERS
- Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
- Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drops by installing the transformers as close to the fixtures as possible.
- Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.
WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:
INJURY TO PERSON:
- Turn off/unplug it and allow it to cool before replacing the lamp.
- The lamp gets HOT quickly. Contact only switch/plug when turning on.
- Do not touch the hot lens, guard, or enclosure.
- Keep lamps away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth. Oil from the skin may damage the lamp.
- Do not operate the luminaire fitting with a missing or damaged shield
- WARNING – Risk of Electric Shock
- May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
- A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
- Supply connection and electrical components are located above ground level, except for the secondary cord that is suitable for wet locations.
LOW VOLTAGE CABLE SHALL:
- Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
- Not be buried except for a maximum of 6″ (152 mm) in order to connect to the main low voltage cable.
- Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or a fitting.
- This product contains . light source of energy efficiency class G.