SmartGen CMM365-4G Cloud Monitoring Communication Module User Manual

June 12, 2024
SmartGen

CMM365-4G Cloud Monitoring Communication Module
User Manual

CMM365-4G Cloud Monitoring Communication Module

Chinese trademark
English trademark
SmartGen — make your generator smart
SmartGen Technology Co., Ltd.
No.28 Jinsuo Road, Zhengzhou, Henan Province, China
Tel: +86-371-67988888/67981888/67992951
+86-371-67981000(overseas)
Fax: +86-371-67992952
Web: www.smartgen.com.cn/
www.smartgen.cn/
Email: sales@smartgen.cn
All rights reserved. No part of this publication may be reproduced in any material form (including photocopying or storing in any medium by electronic means or other) without the written permission of the copyright holder.
Applications for the copyright holder’s written permission to reproduce any part of this publication should be addressed to SmartGen Technology at the address above.
Any reference to trademarked product names used within this publication is owned by their respective companies.
SmartGen Technology reserves the right to change the contents of this document without prior notice.
Table 1 – Software Version

Date Version Note
11/30/2021 1 Original release.

OVERVIEW

CMM365-4G Cloud Monitoring Communication Module is 4G wireless network communication protocol conversion module of all-modes, which can achieve genset (with SCI) connection with Internet. After logging into cloud server, module will receive corresponding genset controller communication protocol from cloud server. Cloud monitoring module can obtain genset data information via RS485 port and send the information to related could server via 4G wireless network. Users can monitor genset running status at real time and check genset running records by mobile APP (IOS or Android), or PC etc. terminal device.
It has GPS and BD positioning function, which can upload the obtained longitude and latitude, altitude information at real time to the corresponding cloud server.

PERFORMANCE AND CHARACTERISTICS

  • Connect to cloud server via 4G wireless network, one cloud monitoring module for one genset;
  • With port for communication with genset control module: RS485, which can monitor most genset control modules of leading brands internationally;
  • Wide power supply: DC (8~35)V, which can directly use engine starting battery;
  • GPS and BD positioning function for obtaining genset location information to realize genset positioning;
  • Apply network data communication protocol of JSON format, upload the genset data changes at real time, meanwhile compression algorithm is applied, which greatly reduces network flow;
  • Upload data to server immediately when genset has alarms;
  • Module panel has power and multiple communication status indicators; clearly display module working status;
  • Parameter setting function: users can do parameter setting by module RS485 port;
  • Modular structure design, flame retardant ABS enclosure, light weight, compact structure with easy installation.

SPECIFICATION

Table 2 – Technical Parameters

Items Contents
Operating Voltage DC(8.0~35.0)V, continuous power supply.
Power Consumption Standby: ≤2W;

Working: ≤2W.
RS485 Port| Non-isolated, half-duplex, 9600 baud rate, max communication distance 1,000m.
Vibration| 5Hz~8Hz, amplitude=17mm;
8Hz~100Hz, a=4g;
100Hz~500Hz, a=2g.
Shock| 50g, 11ms, half-sine, three consecutive shocks are applied in each of the three mutually perpendicular directions, for a total of 18 times.
IEC 60068-2-27
Bump| 25g, 16ms, half-sine;
IEC 60255-21-2.
GPRS Port| Standard SMA port (female), SMA port (male) for antenna.
GPS Port| Standard SMA port (female), SMA port (male) for antenna, active antenna.
Wireless Network| LTE-TDD/LTE-FDD
Case Dimensions| 86mmx61mmx36mm
Working Temperature| (-25~+70)°C
Working Humidity| (20~93)%RH
Storage Temperature| (-25~+70)°C
Conforming Standard| GB/T 37089 Reciprocating internal combustion engine driven alternating current generating sets controller.
Weight| 0.1kg

PANEL AND TERMINAL DESCRIPTION

4.1 PANEL INDICATOR AND KEYS

SmartGen CMM365 4G Cloud Monitoring Communication Module - PANEL
INDICATOR

Table 3 – Indicators Description

Icon Note
POWER (Green) LED Light Green: Normal power supply indication.
ALARM (Red) LED Light Red: Common alarm indication.
RS485 (Red) Normally On: Communication failure;

Flash: Communication normal.
GPS (Red)| Normally Off: GPS is disabled;
Normally On: GPS not obtain satellite signal; Flash: GPS obtains satellite signal.
GPRS/4G (Red)| Off: CMM365-4G module fails to register with server; On: Register with server successfully;
Flash: Real-time data communication normal.

NOTE: The last 15 digits of the cloud modem ID is the IMEI number of chip.
4.2 GPRS ANTENNA PORT
Connect GPRS antenna to GRRS/4G port.
Antenna port: 50Ω/SMA female.
4.3 GPS ANTENNA PORT
After GPS is enabled, connect GPS antenna to CMM365-4G.
Antenna port: 50Ω/SMA female, active antenna.
NOTE: GPS antenna needs to be placed to open outdoors, otherwise location information may be inaccurate.

SmartGen CMM365 4G Cloud Monitoring Communication Module - ANTENNA
PORT Fig.2 – CMM365-4G Antenna Connection

NOTE: GPRS antenna and GPS antenna cannot be connected reversely.
4.4 SIM CARD INSTALLATION
Insert 4G SIM card. CMM365-4G will connect to server via wireless mobile network.
NOTE: This module supports 4G wireless network of all modes. Standard SIM card is applied (size: 25mmx15mm). When GPS indicator and GPRS indicator flash at the same time, it means SIM card is not inserted or SIM card is in bad contact.
After removing the head cover, the installation steps are as below:

1. Open the head cover| 2. Unlock| 3. Open the SIM slot| 4. Insert the SIM card| 5. Lock the SIM card| 6. Buckle the head cover
---|---|---|---|---|---
SmartGen CMM365 4G Cloud Monitoring Communication Module - SIM Card
Installation

4.5 RS485 PORT
Receive genset data information by connecting RS485 port with genset controller RS485 port. 120Ω terminal resistor is recommonded to use if communication fails, short connect A(+) and TR terminal.

SmartGen CMM365 4G Cloud Monitoring Communication Module - RS485
PORT

It is connected to PC USB port through RS485 port and SG72A transfer, all parameters can be configured and CMM365-4G module ID & login password can be viewed.

SmartGen CMM365 4G Cloud Monitoring Communication Module - PC Connection
Diagram

4.6 TERMINALS

SmartGen CMM365 4G Cloud Monitoring Communication Module -
TERMINALS

Table 4 – Terminals Description

No. Function Cable Size Remark
1 B- 1.0mm² Connected with negative of starter battery.
2 B+ 1.0mm² Connected with positive of starter battery. 3A fuse is

recommended.
3| RS485 (TR)| 0.5mm²| Terminal matching resistor wiring terminal.
4| RS485 A(+)| 0.5mm²| 120Ω shielding line is recommended to use with single end grounded.
5| RS485 B(-)| 0.5mm²

NOTE: RS485(TR) and A(+) short connection is equvalent to bus parallel with a 120Ω matching resistor.

PROGRAMMABLE PARAMETERS

5.1 CONTENTS AND SCOPES OF PARAMETERS
Table 5 – Parameter Contents and Scopes

No. Items Parameters Defaults Description

Gateway
1| Site Name| | 20 Chinese characters, letters or numbers.
2| Server URL| | www.smartgencloudplus.com| 40 characters
3| Server Port| (0-65535)| 21318
4| Module Password| | 123456| 16 characters
GPS
1| GPS Enable| (0-1)| 1| 0: Manual Input 1: GPS Location
2| Longitude| ((-180)-180)°| 114.| GPS location, altitude information.
3| Latitude| ((-90)-90)°| 35.
4| Altitude| ((-9999.9)-9999.9)m| 100.0

NOTE: Monitored genset controller model needs to be set on the platform, and cloud monitoring module needs to be re-powered after setting.
5.2 PC CONFIGURATION INTERFACE
Connecting the RS485 port of CMM365-4G communication module with PC to configure the parameters.

SmartGen CMM365 4G Cloud Monitoring Communication Module - PC
CONFIGURATIONSmartGen
CMM365 4G Cloud Monitoring Communication Module - Module Monitoring
Interface

NOTE: If need to read or set cloud modem configuration, the upper computer needs to be connected within 30s after cloud modem is powered on, at time time, it enters .configuration mode. The cloud modem enters normal mode adter closing upper computer or disconnecting.

SYSTEM APPLICATION DIAGRAM

One CMM365-4G module connects with one genset monitoring module. It can be connected via RS485 port.

SmartGen CMM365 4G Cloud Monitoring Communication Module - SYSTEM
APPLICATION DIAGRAM

CASE DIMENSION AND INSTALLATION

35mm guide rail cabinet installation or screw-fixed (M4) installation can be applied. Case dimensions are as below:

SmartGen CMM365 4G Cloud Monitoring Communication Module - CASE
DIMENSIONSmartGen CMM365 4G
Cloud Monitoring Communication Module - G Guide Rail
Installation

FAULT FINDING

Table 6 – Fault Finding

Symptoms Possible Solutions
Module No Response with Power Check power voltage;

Check module wiring connections.
GPRS/4G Indicator Off| Check SIM card is inserted or not;
Check GPRS antenna is connected or not.
GPS Not Gain Location| Check GPS parameters are enabled or not;
Check GPS antenna is connected or not and placed outdoor or not.
RS485 Comm. Abnormal| Check wiring connections;
Check RS485’s connections of A and B is reversely connected or not.

PACKING LIST

Table 7 – Packing List

No. Name Quantity Remark
1 CMM365-4G 1
2 GSM Magnetic Antenna 1
3 External GPS Antenna 1
4 Certificate 1
5 User Manual 1

SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD.

Documents / Resources

| SmartGen CMM365-4G Cloud Monitoring Communication Module [pdf] User Manual
CMM365-4G Cloud Monitoring Communication Module, CMM365-4G, Cloud Monitoring Communication Module, Monitoring Communication Module, Communication Module
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>