Honeywell CO25AE Portable Evaporative Air Cooler User Manual
- June 13, 2024
- Honeywell
Table of Contents
- Honeywell CO25AE Portable Evaporative Air Cooler
- Product Information
- Product Usage Instructions
- PARTS DESCRIPTION
- USE & OPERATION
- ROOM COOLING AND HUMIDIFYING
- REMOTE CONTROL
- FILLING WITH WATER
- TECHNICAL SPECIFICATIONS
- ELECTRICAL WIRING DIAGRAM
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Honeywell CO25AE Portable Evaporative Air Cooler
Product Information
Part | Description |
---|---|
(1) | Control Panel |
(2) | Handle |
(3) | Horizontal Louvers |
(4) | Power Cord & Plug |
(5) | Casters |
(6) | Ice Compartment Lid |
(7) | Vertical Louvers |
(8) | Water Level Indicator |
(9) | Remote Control |
(10) | Water Fill Door |
(11) | Drain Plug |
(12) | Water Tank |
Product Usage Instructions
WARNING: Read and save the Air Cooler Safety & Maintenance Guide and User
Manual before using this product. Failure to follow these instructions may
damage and/or impair its operation and void the warranty. In case there is any
inconsistency
or conflict between the English version and any other language version of the
content of this material, the English version shall prevail.
Control Panel
Button | Description |
---|---|
POWER | Press the POWER button to turn the unit on. The cooler will |
start automatically at medium speed. After a few seconds, the speed
will switch to low. To turn the unit off, press the button
again.
SPEED| Press the SPEED button repeatedly to change the speed between
Low (Lo) – Medium (Med) – High (Hi) – Natural (Natural). The
Natural mode randomly changes between High, Medium, and Low speeds
to mimic a natural breeze.
TIMER| Press the TIMER button until the desired time duration setting
is selected. When the set time has passed, the unit will
automatically turn off (unit remains in Standby mode until power
cord is unplugged from electrical socket). The TIMER function
allows you to program the unit for up to 7.5 hours of use.
SWING| Press the SWING button until the SWING indicator light is
illuminated on the control panel. The louvers will begin to move
left to right automatically. You can manually adjust the louvers to
change vertical air flow.
MODE| Press the MODE button to select COOL and FAN modes. Pressing
the MODE button until COOL is illuminated on the control panel
activates evaporative cooling. Pressing the MODE button until FAN
is illuminated switches the unit to fan-only mode, without
evaporative cooling.
Room Cooling and Humidifying
In cooling mode, Honeywell Air Coolers provide moisturized air through the evaporation of water. There is a manual Water Regulator knob located in the ice compartment of the unit. This allows you to adjust the amount of water pumped over the Honeycomb Cooling Media, thus helping to control cooling and humidification levels.
Water Regulator Setting | Description |
---|---|
MIN | The water pump distributes a minimal amount of water to the |
Honeycomb Cooling Media, resulting in less water evaporation and
reduced cooling effect.
MAX| The water pump distributes the maximum amount of water to the
Honeycomb Cooling Media, resulting in maximum water evaporation and
improved cooling performance.
Portable Evaporative Air Cooler
User Manual
Read and save these instructions before use
PARTS DESCRIPTION
- Control Panel
- Handle
- Horizontal Louvers
- Power Cord & Plug
- Casters
- Ice Compartment Lid
- Vertical Louvers
- Water Level Indicator
- Remote Control
- Water Fill Door
- Drain Plug
- Water Tank
WARNING — READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL PREVAIL.
USE & OPERATION
CONTROL PANEL
FUNCTION BUTTONS
POWER
Press the POWER button to turn the unit on. The cooler will start
automatically at medium speed. After a few seconds the speed will switch to
low. To turn the unit off, press the button again.
SPEED
Press the SPEED button repeatedly to change the speed between Lo – Med – Hi –
Natural.
The indicator light will show the selected speed:
When the Natural mode is selected, The fan will randomly change between High, Medium and Low speeds to mimic a natural breeze.
TIMER
Press the TIMER button until the desired time duration setting is selected.
When the set time has passed, the unit will automatically turn off (unit
remains in Standby mode until power cord is unplugged from electrical socket).
The TIMER function allows you to program the unit for up to 7.5 hours of use.
SWING
Press the SWING button until the SWING indicator light is illuminated on the
control panel. The louvers will begin to move left to right automatically.
Vertical Air Flow – You can manually adjust the louvers to change vertical air
flow.
MODE
Press the MODE button to select COOL and FAN modes. Pressing the MODE button
until COOL is illuminated on the control panel activates evaporative cooling.
The water pump will operate and you will feel the cooler air after the
Honeycomb Cooling Media is completely wet.
Pressing the MODE until Fan is illuminated switches the unit to a fan only
mode, without evaporative cooling.
ROOM COOLING AND HUMIDIFYING
In cooling mode, Honeywell Air Coolers provide moisturized air through the
evaporation of water. There is a manual Water Regulator knob located in the
ice compartment of the unit. This allows you to adjust the amount of water
pumped over the Honeycomb Cooling Media, thus helping to control cooling and
humidification levels.
When the Water Regulator is set to MIN, the water pump distributes a minimal
amount of water to the Honeycomb Cooling Media. This results in less water
evaporation and reduces the cooling effect.
When the Water Regulator is set to MAX, the water pump distributes the maximum amount of water to the Honeycomb Cooling Media. This results in maximum water evaporation and the cooling performance improves.
REMOTE CONTROL
Note
- The remote control requires AAA (2 x 1.5V) batteries for replacement.
- Open the battery compartment at the back of the remote control and insert the batteries inside. Care must be taken to insert the batteries according to the correct polarity (+ / –) markings shown inside the battery compartment.
REMOTE CONTROL (CONTINUED)
- Always point the remote control signal transmitter towards the unit when operating. Make sure that the signal path is not obstructed.
- Remove the batteries if the unit is not going to be used for an extended period of time.
- Do not drop the remote control.
- Do not mix different types of batteries such as alkaline, carbon-zinc, or rechargeable batteries. Do not mix old and new batteries.
- Do not recharge the battery.
- Exhausted batteries are to be removed from the product and safely disposed of as per local regulations.
- Do not dispose of batteries in fire. Batteries may explode or leak.
- WARNING: Caution for ingestion of the small battery. Keep away from children and animals.
COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start using the product. Please refer to the COOLER LOCATION section of the separate Safety & Maintenance Guide.
FILLING WITH WATER
CAUTION:
Unplug the unit from the electrical power outlet before emptying or refilling
the water tank.
Open the Water Fill Door located on the side of the unit.
The Water Level Indicator is located at the front of the unit. Refill the water
tank when water level is low. Do not fill water above the “Max.” water level
mark to avoid water droplets collecting on the louvers. Check the water level
in the tank before running the COOL function. Make sure that the water in the
tank is above the minimum water level mark. Running the unit in COOL mode with
inadequate water may cause pump failure.
Note: The water capacity refers to the total volume of water that can be
contained within the air cooler water tank and water distribution system. The
water capacity in the tank at the “Max.” indicator level may be lower than the
actual water capacity of the air cooler.
Note: If ice is available, you may add ice in the top ice compartment to
enhance the cooling performance.
WARNING: Do not fill water tank with dirty water or salt water. This can
damage the unit and Honeycomb media.
LOW WATER ALARM
The unit is equipped with a low water sensor. In Cooling Mode, when water in
the tank is below the minimum level, you will hear a beeping sound and the
TANK EMPTY indicator light will flash continuously. The unit will automatically
pause evaporative cooling.
LOW WATER ALARM (CONTINUED)
Refill the water tank to deactivate the alarm in cooling mode. First switch OFF
the unit and unplug from the power outlet. Fill the water tank with water
above the minimum water level mark. Plug in and switch ON again.
To deactivate the alarm and continue using the unit as a fan (without
evaporative cooling), switch the unit OFF and then ON again. The Low Water
Alarm will not activate in Fan only mode. The Low Water Alarm will sound again
if the COOL function is activated while the water tank is still empty.
CLEANING & DRAINING THE WATER TANK
Below are instructions on how to clean and maintain your air cooler. If the cooler will not be used for a long period of time, please refer to the STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance Guide.
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the
electrical socket.
- Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty.
- Refill the water tank with clean water, up to the maximum level and drain it completely.
- Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
- When the product is not in use, store the unit in a dry place out of direct sunlight.
*CLEANING THE CARBON DUST FILTER AND HONEYCOMB COOLING MEDIA**
- The appliance is supplied with a Carbon Dust Filter* & Honeycomb Cooling Media.
- The Carbon Dust Filter* and Honeycomb Cooling Media are located inside the Rear Grill. See Figure 1 for instructions on how to remove them from the unit for cleaning and maintenance.
- Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time.
- The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.
- For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off.
*Removing the Carbon Dust Filter/ Honeycomb Cooling Media:**
- Remove all the screws from the Rear Grill.
- Carefully push the left and right side of the rear grill and pull out from the cooler.
- Pull out the Carbon Dust Filter* and clean with water as needed.
- To release the Honeycomb Media pull out the Rear Frame and slide the Honeycomb out of the frame. Replace or clean media with water and a damp cloth as needed.
- WARNING: DO NOT operate the Air Cooler when the Rear Grill or Rear Frame is removed from the Air Cooler, or if there is a loose-fitting Rear Grill or Rear Frame. Doing so can cause serious injury or dangerous electrical shock.
*Applicable for models with Carbon Dust Filter only.
TECHNICAL SPECIFICATIONS
- Model: CO25AE
- Voltage: 110 – 120 V
- Frequency: 60 Hz
- Ampere: 2.1 A
- Wattage: 235 W
- Cooling Media: Honeycomb
- Product Dimension: 480 (W) x 370 (D) x 847 (H) mm 18.9 (W) x 14.6 (D) x 33.3 (H) in
- Net Weight: 11.7 kg / 25.8 lbs
ELECTRICAL WIRING DIAGRAM
For USA Outdoor Models Only. This appliance is equipped with a GFCI plug.
Press the TEST button and then the RESET button once every month to ensure
proper operation.
JMATEK North America LLC Mahwah, New Jersey 07495 USA Phone:
1-800-474-2147
Email: usinfo@jmatek.com Web:
www.jmatek.com
© 2016 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license from Honeywell International
Inc.
Honeywell International Inc. makes no representations or warranties with
respect to these products.
This product is manufactured by Airtek Int’l Corp. Ltd. (subsidiary of JMATEK
Ltd.)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>