MOXA UC-2200A Series Dual Core 64 Bit Industrial Computers Installation Guide
- June 16, 2024
- MOXA
Table of Contents
- UC-2200A Series Dual Core 64 Bit Industrial Computers
- Overview
- Package Checklist
- Panel Layouts
- LED Indicators
- Installing the UC-2200A
- Connector Descriptions
- Specifications
- Accessing the UC-2200A Using a PC
- BSMI Certification for Taiwan
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UC-2200A Series
Quick Installation Guide
Version 1.1, November 2023
UC-2200A Series Dual Core 64 Bit Industrial Computers
Technical Support Contact Information www.moxa.com/support
P/N: 1802022220011
Overview
The UC-2200A computing platform is designed for embedded dataacquisition applications. The UC-2200A computer comes with two RS232/422/485 serial ports, two 10/100/1000 Mbps Ethernet ports, and a Mini PCIe socket to support cellular modules. These versatile communication capabilities let users efficiently adapt the UC-2200A to a variety of complex communications solutions.
Package Checklist
Before installing the UC-2200A, verify that the package contains the following items:
- UC-2200A Series computer
- 3 round stickers for the screws to preventing tampering
- Quick installation guide (printed)
- Warranty card
IMPORTANT!
Notify your sales representative if any of the above items are missing or
damaged.
Panel Layouts
The following figures show the panel layouts of the UC-2200A:
Top Panel View Bottom Panel
View Front Panel View
LED Indicators
LED | Status | Function |
---|---|---|
Power | Green | Power plugged in |
OFF | Power is OFF | |
SW Ready/ Programmable | Yellow | System is ON and the computer is working |
normally
OFF| System is not ready.
USB/ Programmable| Green| USB device is connected and working normally
OFF| USB device is not connected
SD/ Programmable| Green| Micro SD card inserted and working normally
OFF| Micro SD card is not detected.
Wireless Signal Strength/ Programmable| Yellow| The number of glowing LEDs
indicates the signal strength:
2 (both Yellow): Excellent
1 (Yellow): Poor
1 (Yellow, blinking, heartbeat): Very Poor
OFF| Wireless module is not detected.
Serial Tx| Green| Steady ON: Serial 1/2 not working normally Blinking: Serial
1/2 transmitting data
OFF| Serial 1/2 not used
Serial Rx| Yellow| Steady ON: Serial 1/2 working normally Blinking: Serial 1/2
receiving data
OFF| Serial 1/2 not being used.
LAN| Green| Steady ON: A 10/100 M link has been established
Blinking: Receiving or Transmitting data
Yellow| Steady ON: A 1000 M link has been established
Blinking: Receiving or Transmitting data
OFF| No Ethernet connection
Installing the UC-2200A
DIN-rail Mounting
The stainless-steel DIN-rail mounting plate comes attached to the product’s
casing (the specification for the screws is M3 x 6 mm). To mount the UC-2200A
on to a DIN rail, make sure that the stiff metal spring is facing upwards and
follow these steps.
- Insert the top of the DIN rail into the slot just below the upper hook of the DIN-rail bracket.
- Latch the unit firmly onto the DIN rail as shown in the illustrations below:
Wall Mounting (optional)
The UC-2200A can be mounted using a wall-mounting kit, which needs to be
purchased separately. Follow these steps to mount the computer on to a wall:
Step 1: Use four screws (M3 x 4 mm) to fasten the wall-mounting brackets
on the left panel of the computer. Step
2: Use another four screws (M3 x 6 mm) to mount the computer on a wall or a
cabinet.
Connector Descriptions
Power Connector
Connect the power jack (in the package) to the UC-2200A’s DC terminal block
(located on the top panel), and then connect the power adapter. It takes about
30 seconds for the system to boot up. Once the system is ready, the Power LED
will light up.
ATTENTION
The wiring for the input terminal block should be installed by a skilled
person. The wire type should be copper (Cu), wire size should be 14 to 16 AWG,
and a torque of 0.19 n-m should be used for V+, V-, and GND connections. The
wire size of the power input and earthing conductor should be the same.
WARNING
The product is intended to be supplied by a UL Listed Power Unit marked
“L.P.S.” (or “Limited Power Source”) and is rated 12 to 24 VDC, 0.9 A min.,
Tma = 75°C (min). If you need further help with purchasing the power source,
please contact Moxa for further information.
WARNING
The means of power cord of adapter should be connected to a socket-outlet with
earthing connection.
WARNING
EXPLOSION HAZARD!
Do not disconnect equipment unless the power has been removed or the area is
known to be non-hazardous.
Grounding the UC-2200A
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI).
SG: The Shielded Ground (sometimes called Protected Ground) contact is the
right-most contact of the 3-pin power terminal block connector when viewed
from the angle shown here. Connect the SG wire to an appropriate grounded
metal surface.
Ethernet Ports
The two 10/100/1000 Mbps Ethernet ports (LAN 1 and LAN 2) come with RJ45
connectors. The pin diagram of the ports is given below: 10/100 Mbps
Pin | Signal |
---|---|
1 | Tx+ |
2 | Tx- |
3 | Rx+ |
4 | – |
5 | – |
6 | Rx- |
7 | – |
8 | – |
1000 Mbps
Pin | Definition |
---|---|
1 | TRD(0)+ |
2 | TRD(0)- |
3 | TRD(1)+ |
4 | TRD(2)+ |
5 | TRD(2)- |
6 | TRD(1)- |
7 | TRD(3)+ |
8 | TRD(3)- |
Serial Ports
The two serial ports (P1 and P2) come with terminal-block connectors. Each
port can be configured by software for the RS-232, RS-422, or RS-485 mode. The
pin assignments for the ports are given below:
Pin | RS-232 | RS-422 | RS-485 |
---|---|---|---|
1 | TXD | TXD+ | – |
2 | RXD | TXD- | – |
3 | RTS | RXD+ | D+ |
4 | CTS | RXD- | D- |
5 | GND | GND | GND |
Micro SD/SIM Card Sockets
The UC-2200A comes with a Micro SD socket for storage expansion and a SIM card
socket for cellular communication. The Micro SD card and SIM card sockets are
located on the lower part of the front panel. To install the cards, remove the
screw and the protection cover to access the sockets and insert the Micro SD
card or the SIM card into the sockets. Make sure you insert the cards in the
correct direction. Refer to the instructions above the socket. You will hear a
click when the cards are in place. To remove the cards, push the cards in
before releasing them. Console Port
The console port is an RS-232 port that can be connected to a 4-pin pin header
cable. You can use this port for debugging or firmware upgrade. The console
port is located on the top panel of the device and is accessible after
removing the cover of the slot.
Pin | Signal |
---|---|
1 | TxD |
2 | RxD |
3 | NC |
4 | GND |
USB Port
The USB 2.0 port is located at the lower part of the front panel. By default,
the USB auto-mount is disable. If enabled, the USB storage is mounted at
/media/USB_P1 /media/USB_P2.
Antenna Connectors There are
three antenna connectors on the front panel of the UC-2200A. W1 and W2 are for
cellular modules. A GPS antenna connector is located at the top of the front
panel. All three connectors are of SMA type.
Real-time Clock
The real-time clock in the UC-2200A is powered by a lithium battery. We
strongly recommend that you do not replace the lithium battery without the
help of a Moxa support engineer. If you need to change the battery, contact
the Moxa RMA service team.
ATTENTION
There is a risk of explosion if the battery is replaced with an incorrect type
of battery. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s
instructions.
Placing a Round Sticker on a Screw
Three round stickers are included in the product package. Stick one of them on
to an external screw as indicated in the figure below to help detect
unauthorized access and tampering.
Follow these steps to place the stickers.
- Use a cloth to clean the surface of the screws with a 75% alcohol solution.
- Use a tweezer to place the stickers.
- Press the sticker down on to the screw with 15 psi (pound/square inch) pressure for at least 15 seconds.
- Keep the device at room temperature for 24 hours before deploying the devices in harsh environments.
NOTE
- Place the stickers carefully as they are thin and fragile.
- The ideal environment for the stickers to be stored in is 22°C (72°F) and 50% relative humidity.
- Keep the extra two stickers in a safe place so that only authorized persons can access them.
Specifications
Input Current| Models Without Built-in LTE: 600 mA @ 12 VDC
300 mA @ 24 VDC
Models With Built-in LTE: 900 mA @ 12 VDC
450 mA @ 24 VDC
---|---
Input Voltage| 12 to 24 VDC (3-pin terminal block, V+, V-, SG)
Power Consumption| Models Without Built-in LTE:
4.5 W (w/o external USB device attached)
7.2 W (external USB device attached) Models With Built-in LTE:
7.8 W (w/o external USB device attached)
10.5 W (external USB device attached)
Operating Temperature| Models Without Built-in LTE:
-40 to 75°C (-40 to 167°F)
Models With Built-in LTE:
-40 to 70°C (-40 to 158°F)
Storage Temperature| -40 to 80°C (-40 to 176°F)
Accessing the UC-2200A Using a PC
You can use a PC to access the UC-2200A by one of the following methods:
A. Through the serial console port with the following settings:
Baudrate=115200 bps, Parity=None, Data bits=8, Stop bits =1, Flow Control=None
ATTENTION
Remember to choose the “VT100” terminal type. Use the console cable to connect
a PC to the UC-2200A’s serial console port
B. Using SSH over the network. Refer to the following IP addresses and login
information:
| Default IP Address| Netmask
---|---|---
LAN 2| 192.168.4.127| 255.255.255.0
Login: moxa
Password: moxa
BSMI Certification for Taiwan
Declaration of the Presence Condition of the Restricted Substances Marking
Equipment name
Type designation (Type)
Unit| Restricted substances and its chemical symbols
Lead (Pb)| Mercury (Hg)| Cadmium (Cd)| Hexavalent chromium
(Cr+6)| Polybrominat ed biphenyls (PBB)| Polybrominated diphenyl ethers (PBDE)
shell| ○| ○| ○| ○| ○| ○
Printed circuit boards and their electronic components pieces| –| ○| ○| ○| ○|
○
cable/wire/ Connector| –| ○| ○| ○| ○| ○
Mechanical components-Metal| | ○| ○| ○| ○| ○
Mechanical components-nonmetal| ○| ○| ○| ○| ○| ○
Note 1: “Exceeding 0.1 wt %” and “exceeding 0.01 wt %” indicate that the
percentage content of the restricted substance exceeds the reference
percentage value of presence condition.
Note 2: “○” indicates that the percentage content of the restricted
substance does not exceed the percentage of reference value of presence.
Note 3: The “−” indicates that the restricted substance corresponds to
the exemption.
Warning: To avoid electromagnetic interference, this product should not
be installed or used in residential environments.
Warning: Replacing an incorrect battery type may cause explosion. Please
dispose of used batteries according to the manufacturer’s instructions.
Manufacturer: 404 Technology Co., Ltd.
Address: 13th Floor, No. 3, Section 4, New Taipei Avenue, Xinzhuang
District, New Taipei City
Service hotline: 02 8919 1230
This device has undergone a suitability assessment for use in a business
environment.
As a device, there is a risk of radio interference if used in a home
environment.
Company Name: Moxa Inc.
Equipment name: LTE mobile communication wireless equipment (others)
Model Name: UC-2222A-T, UC-2222A-T-AP
Manufacturer and country of manufacture: Moxa Inc. / taiwan
References
Read User Manual Online (PDF format)