MCO Home MH-4936 Z Wave Thermostat Instruction Manual

June 13, 2024
MCO HOME

MCO Home MH-4936 Z Wave Thermostat

MCO Home MH-4936 Z Wave Thermostat-product

VIEW ALL MCO-Home THERMOSTAT MANUAL

Introduction

MH4936 thermostat is used to control up to 3 stages heating and 2 stages cooling system with 8 types control system, EM heat activation, adjustable compressor delay time and O/B changeover. With quick connecting terminals to save installer’s time. Support S2 function.

Technical Parameters

  • Power Supply: AC/DC24V / 4* AA dry battery
  • Sell-Consumption: <lW
  • Resistive Load: < IA
  • Temp. Setting Range: 10?37C
  • Precision: 0.1 C(l “F)
  • Outcase: Tempered glass +PC+ABS
  • Thermistor: NTC thermistor
  • Wire Connection: Terminal
  • Dimension: 114 114 22mm
  • Installation: 60.3mm hole pitch
  • Z-Wave Frequency: Operating frequency range, defined by the regulatory bodies (for Z-wave in Europe: 868.0 -868.6 MHz, 869.7 – 870.0 MHz)

Features

  • Application range: gas/fuel boiler, electric heating, water heating, heat pump etc. 8 types control systems.
  • Z-Wave 800 series, support S2 encryption function.
  • Touch button operation interaction.
  • Simpler way to connect wires without screwdriver.

Declaration of Conformity

Hereby, we declare that the device is in compliance with the  essential requirements and other relevant provisions of Directive 2014/53/EU.

WEEE Directive Compliance

The device marked with this symbol should not be disposed of with household waste. It is the user’s responsibility to deliver the used appliance to a designated recycling point.

Z-Wave Compliance

The device is a fully compatible Z-Wave Plus device.

Wires Connection Instruction

  • Read the instructions before starting np the unit!
  • This product is not a toy. Keep out of reach of children and animals!
  • Do not expose the device to moisture, water or other liquids. Do not place liquids near or on the device!
  • Do not attempt to disassemble, repair or modify the device yourseH!
  • This product is for indoor use only. Do not use outdoors!

CAUTIONS!
Risk of Electric Shock – More than one disconnect switch may be required to de-energize the equipment before servicing.

CAUTIONS!
Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly.

MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal.

Wiring diagram

REQUIRED: 24 VAC POWER (“C” WIRE)

MCO Home MH-4936 Z Wave Thermostat-fig2

Terminal Description
C

AC 24 V power supply

RH
RC
WI| Is, stage heating
W2| 200 stage heating or auxiliary heating
G| Fan
YI| Compressor stage I
Y2| Compressor stagc2
0/B| Changeover
K| Wire with 4-5T module
EF| Reserved terminal

Note: A wire saver acts as a splitter for applications that do not include a 24-volt C wire. If your heating/cooling system does not include a C wire,install the wire saver in or near the main unit (furnace, air handler) of your heating/cooling system.

Controlling Type

MCO Home MH-4936 Z Wave Thermostat-fig4

Display

MCO Home MH-4936 Z Wave Thermostat-fig5

Functions & Settings

  • Setpoint Setting
    Press “/\”or ” V” to set the desired indoor temperature. Setting range: 5~37 t (41~98 “F) by default.

  • Mode Setting
    This device supports OFF, HEAT, COOL, AUTO mode and EM mode (not enabled by default). Press the “MODE” button to switch the working mode.

  • Fan Mode Setting
    Short press the “FAN” key to switch the working mode of the fan.

  • Fan On
    In this mode, the fan is always running when it is turned on, and stops when it is turned off.

  • Fan Auto
    In this mode, the fan runs both in cooling and heating state ; the fan stops when cooling or heating is stopped, when the device is in shutdown state, the fan stops.

  • Secret Menn
    Under “OFF” interface, long press “MODE” button for 3 sec to enter into parameter setting interface. Short press “MODE11 button to switch the parameter number, press A “or” V “to modify the corresponding setting value, and then press “FAN” to confirm and then exit.

Menu Number Item Setting Range Default Description
01 Restore factory setting 0-99 53 Default 53, change to 55 to restore

factory setting

02

|

Device state after power failure

|

0- I

| | 0 : device turn to OFF state

I: device return to last stat before power failure

04| Beep volume| 1-5| | I: Mute            2: Low

3: Medium  4: High           5: Normal

06| Temp. setting upper limit| 1-99| 37C/98F| gap I
07| Temp. setting bottom limit| 0-98| 5 C/41F|
08| Indoor temperature calibration| -9.9-+9.9| | -9.9-+9.9
09| Indoor humidity calibration| -20-+20| | -20- +20
II| Temp. deadband| 0-9.0| 1.0 C/2.0 F|
12| Temp. format| 0-1| | 0: Celsius              I: Fahrenheit

13

|

Controlling type

|

00-07

|

07

| Conventional cooling/heating system

0= cool only              I= heat only            2= cool or heat

Heat pump cooling/heating system

3= cool only              4= heat only           5= two stages heat 6= single cooling/single heating+ AUX

7= two stages cooling/ two stages heating+ AUX

14

|

Changeover valve logic

|

0-1

| | 00=When the heat pump cooling starts, 0/B turned on, but turned off when heating

01=When the heat pump heating starts, 0/B turned on, but turned

off when cooling

15

|

Compressor protection time

| 0-10

unit: minute

| | Indicates the setting of compressor delay time from shutdown to startup

16

|

EM emergency heating mode

|

ON/OF

|

OF

| ON=turn on emergency heating mode OF=turn off emergency heating mode

Only available for heat pump system with heating function

Z-Wave Setting

1. Include into Z-Wave network
Under the normal working interface, long press” A “and” V ”button synchronously for 3sec, the device will enter Z-WAVE MENU interface, iflong press” A “and” V” button synchronously for 3sec again or without any operation for 10sec, it will back to the homepage. Before the device included into network,”- – -” will display on the screen. Then short press ” A” button, device will enter learning mode to get a node ID. If inclusion is success, a node ID will display on the screen in a few seconds. Note: A node ID can always inform us whether the device is in the network or not.
Exclude from Z-Wave network
Under the normal working interface, long press” A “and” V ”button synchronously for 3sec, the device will enter Z-WAVE MENU interface, iflong press” A “and” V” button synchronously for 3sec again or without any operation for 10sec, it will back to the homepage. Current ID displays on the screen, short press ” A” button, device will enter learning mode, current ID will flash, once “- – -” display on the screen, the device has excluded from Z-Wave network.

Z-WAVE supported Connnand Class:
Support S2:

  • COMMAND CLASS VERSION,

  • COMMAND_CLASS_POWERLEVEL,

  • COMMAND_CLASS_MANUFACTURER_SPECIFIC,

  • COMMAND_CLASS_BATTERY,

  • COMMAND_CLASS_DEVICE_RESET_LOCALLY,

  • COMMAND_ CLASSSENSOR MULTILEVEL V5,

  • COMMAND CLASS THERMOSTAT_ SETPOINT,

  • COMMAND CLASS THERMOSTAT OPERATING STATE,

  • COMMAND_CLASS_THERMOSTAT_FAN_STATE,

  • COMMAND CLASS ASSOCIATION_ V2,

  • COMMAND CLASS ASSOCIATION_ GRP INFO,
    Not support S2:

  • COMMAND CLASS THERMOSTAT_ MODE,

  • COMMAND_CLASS_THERMOSTAT_FAN_MODE,

  • COMMAND_CLASS_CONFIGURATION,

  • COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,

  • COMMAND CLASS FIRMWARE UPDATE MD V5

  • COMMAND CLASS ZWAVEPLUS _ INFO,

  • COMMAND CLASS SECURITY_ 2,

  • COMMAND CLASS TRANSPORT SERVICE V2,

  • COMMAND CLASS SUPERVISION

AG

identifier

| Max Node ID| Command Classes| Trigger Situation
---|---|---|---

0x0I

| |

COMMAND_CLASSSENSOR MULTILEVEL_ VS, SENSOR_MULTILEVEL_REPORT_V5

| I. The gap of the value of current temperature and that of last reporting temperature to gateway is greater than setting value of parameter 2.

2. The gap of the value of current humidity and that of last

reporting humidity to gateway is greater than setting value of parameter 3.

COMMAND_CLASS_THERMOSTATMODE V2, THERMOSTAT_MODE_REPORT|

Device mode changes

COMMAND_CLASS_THERMOSTAT_OPERATING_STATE, THERMOSTAT_OPERATING_STATE_REPORT| Device status changes
COMMAND_CLASS_THERMOSTATFAN MODE, THERMOSTAT_FAN_MODE_REPORT|

Device mode changes

COMMAND_CLASS_THERMOSTATFAN STATE, THERMOSTAT_FAN_STATE_REPORT| Device status changes
COMMAND_CLASS_THERMOSTATSETPOINT V2, THERMOSTAT_SETPOINTREPORT V2|

Setpoint value changes

COMMAND_CLASS_DEVICE_RESET_LOCALLY, DEVICE_RESET_LOCALLY_NOTIFICATION|

Restore factory setting

COMMAND_CLASS_BATTERY, BATTERY_REPORT| The change in battery power is greater than 5%

4. Z-Wave Parameters Settings

Number Function Size Description Default Possible Values
Secret menu E12: Temp Unit 0: Celsius            1: Fahrenheit 0-1

Upload temperature difference

| | Unit: 0.1C               0: Disabled

3-255:n*0. I C; A temperature value greater than this will be uploaded to the gateway automatically

| |

0, 3-255

Unit: 0.1F 0, 3-255            0: Disabled

3-255:n*0.1F; A temperature value greater than this will be uploaded to the gateway automatically

|

10

|

Upload humidity difference

| | 0: OFF

1-99: A humidity value greater than this will be uploaded to the gateway automatically.

| |

0-99

12

|

Secret menu E02: device state after power failure

| |

0 : device turn to OFF state

I: device return to last stat before power failure

| |

0-1

14

|

Secret menu E04:BEEP

| | 1: Mute             2: Low

3: Medium         4: High          5: Normal

| |

1-5

16

|

Secret menu E06: Temp.setting upper limit

| |

Set temperature upper value,upper>lower(Temperature unit follows the device’s unit setting)

|

37(Celsius)

|

1-99

98(Fahrenheit)

17

|

Secret menu E07: Temp.setting bottom limit

| |

Set temperature lower value,upper>lower(Temperature unit follows the device’s unit setting)

| 5(Celsius)|

0-98

4 l(Fahrenheit)

18

|

Secret menu E0S: Indoor temperature calibration

| |

Temperature calibration value (Temperature unit follows the device’s unit setting), precision: 0.1 (n*0.1)

| |

(-99 – +99)Celsius

(-99- +99)Fahrenheit

19| Secret menu E09: Indoor humidity calibration| | Humidity calibration value| | -20-+20

22

|

Secret menu E11:Temp. deadband

| |

Precision: 0.1(n*0. l)

|

I0(Celsius)

|

(0 – 99)Celsius

20(Fahrenheit)

|

(0 – 99)Fahrenheit

Number Function Size Description Default Possible Values

23

|

Secret menu E13:controlling type

| | Conventional cooling/heating system

0= cool only 2C                    I heal only 2H 2= cool or heat 2C/2H

Heat pump cooling/ heating system

3   cool only (2C Y I +Y2)

4  hcat only(2H Yl+W2 “AUX”)

5  two stages heal (3H YI+Y2+W2″AUX”) 6= single cooling/single heating +AUX

7= two stages cooling/ two stages heating+ AUX

| |

0-7

24

|

Secret menu E14: changeover valve logic

| | 00=When the heat pump cooling starts, O/B turned on , but turned off when heating

0 I =When the heat pump heating starts, 0/8 turned on, but turned off when cooling

|

0

|

0-1

25

| Secret menu EIS: compressor protection time| | Indicates the setting of compressor delay time from shutdown to startup| |

0-10

26

|

Secret menu EI 6:

EM Emergency Heating Mode

| | ON=tum on emergency heating mode OF=tum off emergency heating mode

Only available for heat pump system with heating function

|

0

|

0-1

255

| Secret menu E0 I: RESET FACTORY| |

Write 85: restore the factory setting (write only)

|

0

|

0, 85

1-Year Limited Warranty

We warrant this product to be free from defects in material and workmanship under normal and proper use for one year from purchase date of the original purchaser. We will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY, ABNORMAL MECHANICAL OR ENVIRONMENTAL CONDITIONS, OR ANY UNAUTHORIZED DISASSEMBLY, REPAIR OR MODIFICATION. This limited warranty shall not apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the product was not used for its intended function. This limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, that has not been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary to Country and other applicable export regulations.