MCO HOME 9 in 1 Multi-Sensor User Manual
- June 7, 2024
- MCO HOME
Table of Contents
User Manual
9 in 1 Multi-Sensor
A8-9
MCOHome A8-9 is a Z-Wave enabled multiple environmental monitoring sensors, with 3.5 inch TFT clear display and compliant to Z-Wave Plus standard. It is built in with Temperature, Humidity, PM2.5, CO2, VOC, PIR, illumination, Noise, Smoke sensors. Device can be added into any Z-Wave network, and is compatible with any other Z-Wave certified devices.
- Temperature: 0~50℃
- Humidity: 0%RH~99%RH
- PM2.5: 0~500ug/m3
- CO2: 0~5000ppm
- VOC: 0-64000ppb
- PIR: 0 or 1 Detection angle up to 120°
- Illumination: 0~40000Lux
- Noise: 30dB~100dB
- Smoke: 0 or 1
Specification
- Power Supply: DC12V
- Self-dissipation:<3W
- Work environment:-20~+60℃ <99%RH (Non-condensation)
- Dimension: 110 11032mm
- Hole Pitch: 60mm or 82mm
- Housing: Tempered glass+ PC Alloy
- Installation: Wall-mounted (Vertical)
Safety Information
To protect yourself and others from danger and to protect the device from damage, please read the safety information before using it.
Important!
- A qualified electrician with the understanding of wiring diagrams and knowledge of electrical safety should complete installation following the instructions.
- Before installation, please confirm the real voltage complying with the device’s specification. Cut off any power supply to secure the safety of people and device.
- During installation, protect the device from any physical damage by dropping or bumping. If happens, please contact the supplier for maintenance.
- Keep the device away from acid-base and other corrosive solids, liquids, gases, to avoid damage.
- Avoid overexertion during operation, to protect device from mechanical damage.
- Read all instructions and documentation and save for future reference.
Installation & Wiring
Location:
Device is suggested to be installed indoor, a place with around 1.5m height
above the floor where represents the average CO2 concentration. It should be
away from direct sunlight, any cover, or any heat source, to avoid false
signal for temperature control.
Notice!
- Device must be wall-mounted vertically. Do not lay it flat or upside down while working.
- Do not mounted it in a wind gap, or cover its bottom, which may affect the detected data.
Step 1:Remove the steel frame from the backside of the device, and then fix it
onto the installation box with 2 screws.
Step 2:Wire the adaptor.
Step 3:Put the device back onto the steel frame, it will attach with the frame
firmly by built-in magnets.
Step 4:Check the installation and power, the device is ready for work.
Operation
Power on/ power off
Wire the adaptor and the device is powered on. It will display all detected
information by the sensors.
Display interface
Hold Key F1 can switch among the following 4 display interfaces:
1. Data detecting: display all sensors’ data
2. Network: Z-Wave Add/Remove
3. Data calibration: to calibrate the detected data manually
4. Local time setting
Z-Wave Operation
Note: A Security Enabled Z-Wave Controller must be used in order to fully
utilize the product.
• Add &Remove Z-Wave network
• Activate Add/Remove mode in the gateway. When device is powered on, hold F1
to choose interface for Add or Remove Z-Wave network.
→ Click F2 five times until turns blue.
→ Hold F2 and the device enters into learning mode, then turns blue and the
device is added into Z-Wave network.
→ Follow the same steps to remove the device from network.
Association Group
Device supports 1 association group:
AG
identifier| Max
Node ID| Command Classes| Trigger situation
---|---|---|---
0x01| 1| COMMAND_CLASS
_SENSOR_MULTIL
EVEL_V5,
SENSOR_MULTILE
VEL_REPORT_V5| Detected value will be reported according to:
1, PM2.5 The value difference between current value and previous reported
value >0x01 set value, set value ≠0;
2, CO2 The value difference between current value and previous reported
value> 0x02 set value, set value≠0;
3, Temperature The value difference between current value and previous
reported value > 0x03 set value, set value≠0;
4, Humidity Thevalue difference between current value and previous reported
value > 0x04 set value, set value≠0;
5, VOC The value difference between current value and previous reported value
0x05 set value, set value≠0;
6, Illumination The value difference between current value and previous reported value > 0x06 set value, set value≠0;
7, Noise The value difference between current value and previous reported value > 0x07 set value, set value≠0;
8, PIR The current state is different from previous reported state, set value≠0;
9, Smoke The current state is differentfrom previous reported state, set value≠0;
10, Smoke IntervalReport Timer set value: 0x0A and set value≠0;
11, PIR IntervalReport Timer set value: 0x0B and set value≠0;
12, PM2.5 IntervalReport Timer set value: 0x0C and set value≠0;
13, CO2 IntervalReport Timer set value: 0x0D and set value≠0;
14, Temperature IntervalReport Timer set value: 0x0E and set value≠0;
15, Humidity IntervalReport Timer set value: 0x0Fand set value≠0;
16, VOC IntervalReport Timer set value: 0x10 andset value≠0;
17, Illumination IntervalReport Timer set value:0x11 and set value≠0;
18, Noise IntervalReport Timer set value: 0x12 andset value≠0;
COMMAND_CLASS
_DEVICE_RESET_L
OCALLY,
DEVICE_RESET_LO
CALLY_NOTIFICAT
ION| Factory setting restored
Command Class supported by the device: ( Supports S2 unauthenticated
level)
COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_DEVICE_RESET_LOCALLY,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_SENSOR_MULTILEVEL,
COMMAND_CLASS_FIRMWARE_UPDATE_MD
Command Class supported by the device: (Not supports S2)
COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_TRANSPORT_SERVICE_V2,
COMMAND_CLASS_SECURITY_2,
COMMAND_CLASS_SUPERVISION
Restore Factory Setting
1, Press & hold F1 to enter Z-Wave setting interface, then press & hold F1
again to enter parameters setting interface;
2, Press & hold F2 to enter setting interface and select “default”;
3, Click F2 3 times and displays “OFF”–>“ON”–>“OK”–>“OFF”, factory setting is
restored.
Note: Please use this procedure only when the network primary controller is
missing or otherwise inoperable
Data Calibration
Hold F1 to choose interface for data calibration. Then hold F2 to switch among
the sensors.
Choose one and click F2, F1 to change the data. After finished, hold F1 can
return data detecting interface.
Local time setting
Hold F1 to choose interface for local time setting. Then hold F2 to switch
among “Hour-Minute-Second-Year-Month-Date”. Click F2, F1 can change the data
of flashing item. After finished, hold F1 can return data detecting interface.
Parameters table
Add | Parameter | Options | Default | Range | |
---|---|---|---|---|---|
0x01 | PM25 Delta Level | 1 | =0 Turn off report |
=1 Report when change >
n 1ug/m3| |
0x02| CO2 Delta Level| I| =0 Turn off report
=1 Report when change >
n 5ppm| 0| 0-127
0x03| Temp_Delta_Level| 1| =0 Turn off report
=1 Report when change > n0.5°C| 0| 0-127
0x04| Humidity_Delta_Level| I| =0 Turn off report
=1 Report when change >n%| 0| 0-127
0x05| VOC Delta Level| I| =0 Turn off report
=I-1275ppb Reportchange| 0| 0-127
6| Lux_Delta_Level| 2| =0 Turn off report
=I Report when change > n1 Lux| 0| 0-32707
0x07| dB Delta Level| 1| =0 Turn off report
=1 Report when change > n I dB| 0| 0-127
Ox08| PIR_DeltaLevel| I| =0 Turn off report
=1 Report change| 0| 0- I
0x09| SMOKE Delta
_ Level| I| =0 Turn off report
=1 Report change| I| 0-1
OxOA| Smoke_Timer| | =0 Turn off report
=35 Report every n1 s
interval| 60| 0.35-3_7o7
OxOB| PIR Timer| 2
Clrl| =0 Turn off report
=35 Report every n Is
interval| 60| 0,35-32767
OxOC| PM25_Timer| | =0 Turn off report
—=35Report every n1 s interval| 120| 0,35-32767
OxOD| CO2_Timer| 2| =0 Turn off report
=35 Report every n1s interval| 120| 0,35-32767
OxOE| Temp_Timer| 2| =0 Turn off report
=35 Report every n 1 s
interval| 180| 0,35-32767
OxOF| Humidity_Timer| 2| =0 Turn off report
=35 Report every n 1 s
interval| 180| 0,35-32767
Oxl 0| VOC_Timer| 2| =0 Turn off report
=35 Report every n1 s
interval| 180| 0,35-32767
Ox11| Lux_Timer| 2| =0 Turn off report
=35 Report every n1 s
interval| 300| 0,35-32767
Ox12| dB_Timer| 2| =0 Turn off report
=35 Report every n* 1 s
interval| 300| 0,35-32767
Ox2F| Temp. unit| 1| =0 °C
=I °F| 0| 0-1
0x32| T_OffSet| 1| 0~ 127:
((n-100)/10)-(-10-2.7)°C
-128 –I:
((156+n)/10(2.8-15.5)°C| 100| -128-127
0x33| RH_OffSet| 1| n-20=(-20-20)%| 20| 0-40
0x34| CO2_OffSet| 2| (n-500(-500-500)ppm| 500| 0-1000
0x35| PM2.5OffSet| 1| 0 ~ 127:
n-100=(-100-27)ug/m3
-128 — -1:
156+n=(28-155)ug/m3| 100| -128-127
0x36| Lux_OffSet| 2| n-500-5000-5000)1ux| 5000| 0-10000
0x37| VOC_Correct| I| 0 ~127:
n-I00=(-100-27)ppb
-128 –I:
156+n-(28-155)ppb| 100| -128-127
0x38| dB_Correct| I| (n-50)=-50-50| 50| 0– IOU
OxFF| Write Only| 1| ===0x55 Restore factory setting
===OxAA Restore default para.| |
1-year Limited Warranty
MCOHome warrants this product to be free from defects in material and workmanship under normal and proper use for one year from the purchase date of the original purchaser. MCOHome will, at its option, either repair or replace any part of its products that prove defective by reason of improper workmanship or materials. THIS LIMITED WARRANTY DOES NOT COVER ANY DAMAGE TO THIS PRODUCT THAT RESULTS FROM IMPROPER INSTALLATION, ACCIDENT, ABUSE, MISUSE, NATURAL DISASTER, INSUFFICIENT OR EXCESSIVE ELECTRICAL SUPPLY, ABNORMAL MECHANICAL OR ENVIRONMENTAL CONDITIONS, OR ANY UNAUTHORIZED DISASSEMBLY, REPAIR, OR MODIFICATION. This limited warranty shall not apply if: (i) the product was not used in accordance with any accompanying instructions, or (ii) the product was not used for its intended function. This limited warranty also does not apply to any product on which the original identification information has been altered, obliterated or removed, that has not been handled or packaged correctly, that has been sold as second-hand or that has been resold contrary to Country and other applicable export regulations.
MCOHome Technology Co., Ltd