MCO Home 9 in 1 MULTI-SENSOR A8-9 Manual
- June 8, 2024
- MCO HOME
Table of Contents
- MCO Home
- 9 in 1 MULTI-SENSOR
- SKU: A8-9
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: PM25_Delta_Level
- Parameter 10: Smoke_Timer
- Parameter 11: PIR_Timer
- Parameter 12: PM25_Timer
- Parameter 13: CO2_Timer
- Parameter 14: Temp_Timer
- Parameter 15: Humidity_Timer
- Parameter 16: VOC_Timer
- Parameter 17: Lux_Timer
- Parameter 18: dB_Timer
- Parameter 2: CO2_Delta_Level
- Parameter 3: Temp_Delta_Level
- Parameter 4: Humidity_Delta_Level
- Parameter 47: Temp. unit
- Parameter 5: VOC_Delta_Level
- Parameter 50: T_OffSet
- Parameter 51: RH_OffSet
- Parameter 52: CO2_OffSet
- Parameter 53: PM2.5_OffSet
- Parameter 54: Lux_OffSet
- Parameter 55: VOC_Correct
- Parameter 56: dB_Correct
- Parameter 6: Lux_Delta_Level
- Parameter 7: dB_Delta_Level
- Parameter 8: PIR_Delta_Level
- Parameter 9: SMOKE_Delta_Level
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MCO Home
9 in 1 MULTI-SENSOR
SKU: A8-9
Quickstart
This is a
secure
Alarm Sensor
for
South Korea.
To run this device please connect it to your mains power supply.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The MCOHome A8-9 is a Z-Wave enabled multi-sensor that can completely monitor your environment and assist with all of your smart home needs.The 3.5 inch touch-screen display allows you to see the sensor information that is also reported to your Z-Wave gateway. The A8-9 includes temperature, humidity, motion and light level like many sensors, but goes far beyond by also providing particular matter (pollution), carbon dioxide, and volatile organic compound levels as well. Security and safety is further enhanced with a noise sensor and smoke detection providing an amazing NINE different sensors in one package.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Plus Lifeline |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: PM25_Delta_Level
=0Turn off report >=1 Report when change > n * 1ug/m3
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127| =0Turn off report >=1 Report when change
>n * 1ug/m3
---|---
Parameter 10: Smoke_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 60
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 11: PIR_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 60
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 12: PM25_Timer
=0Turn off report >=35Report every n*1s interval
Size: 2 Byte, Default Value: 120
SettingDescription
35 – 32767 | >=35Report every n*1s interval |
---|
Parameter 13: CO2_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 120
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 14: Temp_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 180
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 15: Humidity_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 180
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 16: VOC_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 180
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 17: Lux_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 300
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 18: dB_Timer
=0Turn off report >=35 Report every n*1s interval
Size: 2 Byte, Default Value: 300
SettingDescription
35 – 32767 | >=35 Report every n*1s interval |
---|
Parameter 2: CO2_Delta_Level
=0Turn off report >=1 Report when change >n * 5ppm
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127| =0Turn off report >=1 Report when change
> n * 5ppm
---|---
Parameter 3: Temp_Delta_Level
=0Turn off report >=1 Report when change >n*0.5
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127| =0Turn off report >=1 Report when change
> n*0.5
---|---
Parameter 4: Humidity_Delta_Level
=0Turn off report >=1 Report when change >n%
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127| =0Turn off report >=1 Report when change
>n%
---|---
Parameter 47: Temp. unit
=0 =1
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | =0=1 |
---|
Parameter 5: VOC_Delta_Level
=0Turn off report >=1-127*5ppb Reportchange
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127| =0Turn off report >=1-127*5ppb
Reportchange
---|---
Parameter 50: T_OffSet
0 ~ 127: ((n-100)/10)=(-10~2.7)-128 ~ -1:((156+n)/10)=(2.8~15.5)
Size: 1 Byte, Default Value: 100
SettingDescription
-128 – 127 | 0 ~ 127: ((n-100)/10)=(-10~2.7) -128 ~ -1: ((156+n)/10)=(2.8~15.5) |
---|
Parameter 51: RH_OffSet
n-20=(-20~20)%
Size: 1 Byte, Default Value: 20
SettingDescription
0 – 40 | n-20=(-20~20)% |
---|
Parameter 52: CO2_OffSet
(n-500)=(-500~500)ppm
Size: 2 Byte, Default Value: 500
SettingDescription
0 – 1000 | (n-500)=(-500~500)ppm |
---|
Parameter 53: PM2.5_OffSet
0 ~ 127: n-100=(-100~27)ug/m3-128 ~ -1:156+n=(28~155)ug/m3
Size: 1 Byte, Default Value: 100
SettingDescription
-128 – 127 | 0 ~ 127:n-100=(-100~27)ug/m3 -128 ~ -1: 156+n=(28~155)ug/m3 |
---|
Parameter 54: Lux_OffSet
n-5000=(-5000~5000)lux
Size: 2 Byte, Default Value: 5000
SettingDescription
0 – 10000 | n-5000=(-5000~5000)lux |
---|
Parameter 55: VOC_Correct
0 ~ 127: n-100=(-100~27)ppb-128 ~ -1:156+n=(28~155)ppb
Size: 1 Byte, Default Value: 100
SettingDescription
-128 – 127 | 0 ~ 127:n-100=(-100~27)ppb -128 ~ -1: 156+n=(28~155)ppb |
---|
Parameter 56: dB_Correct
(n-50)=-50~50
Size: 1 Byte, Default Value: 50
SettingDescription
0 – 100 | (n-50)=-50~50 |
---|
Parameter 6: Lux_Delta_Level
=0Turn off report >=1 Report when change > n*1 Lux
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32767| =0Turn off report >=1 Report when change
> n*1 Lux
---|---
Parameter 7: dB_Delta_Level
=0Turn off report >=1 Report when change >n*1dB
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127| =0Turn off report >=1 Report when change
> n*1dB
---|---
Parameter 8: PIR_Delta_Level
=0Turn off report=1Report change
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | =0Turn off report =1Report change |
---|
Parameter 9: SMOKE_Delta_Level
=0Turn off report=1 Report change
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 1 | =0Turn off report =1 Report change |
---|
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Notification Sensor |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 6.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-19086697 |
Z-Wave Product Id | 0x015F.0xA803.0x135A |
Firmware Updatable | Updatable by Professional/Technician |
Neutral Wire Required | ok |
Sensors | Air TemperatureCarbon DioxideHumidityLoudnessLuminanceMotion/No |
Motion (Binary)Particulate MatterSmoke DensityVolatile Organic Compound
Security V2| S2_UNAUTHENTICATED
Frequency| XXfrequency
Maximum transmission power| XXantenna
Supported Command Classes
- Association Grp Info
- Association V2
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Powerlevel
- Security 2
- Sensor Multilevel V10
- Supervision
- Transport Service V2
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.