WATTS PR03 RF 230 Vision Wireless Plug Receiver
Product Information
Product Name | Smart Plug PR03 RF |
---|---|
Manufacturer | Watts Electronics |
Website | [wattswater.eu](https://wattswater.eu/catalog/regulation-and-control |
/watts-vision-smart-home/smart-plug-PR03-RF/)
Power Supply| 230VAC 50Hz with European plug socket
Electrical Protection| Cat. II – IP20
RF Frequency| 868,3 MHz
RF Range| 30m in residential environment (100m in open field)
General Information
Safety warnings and operating instructions
- This product should be installed preferably by a qualified professional. Subject to observation of the above terms, the manufacturer shall assume the liability for the equipment as provided by legal stipulations.
- Do not exceed the maximum power rating 10A or 2300W.
- All instructions in this Installation & Operation manual should be observed when working with the smart plug. Failures due to improper installation, improper use or poor maintenance are voiding manufacturer liability.
- This product is for indoor use only. Do not expose to water, dust, chemicals and moisture. Keep away from heat sources and direct sunlight.
- Children should use this device only under the supervision of a responsible adult to control appliances safely.
- Do not drop or subject the device to undue shock.
- Do not attempt to service or disassemble. Any attempt to repair voids the responsibility and the obligation to guarantee and replacement from the manufacturer.
- If you experience problems with the device, discontinue use, unplug the device from the wall outlet and contact your Customer Services for assistance
- Unplug this device during lightning storms or when unused for long periods of time.
- 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info
Application
- The smart plug receiver have been designed for use in residential rooms, office spaces and industrial facilities.
- Verify that the installation complies with existing regulations before operation to ensure proper use of the installation.
Please refer to « Quick Installation Guide » for smart plug receiver installation
Presentation
- Vision® Smart Plug is compatible with Watts Vision® system.
- Wireless bidirectional communication 868,3 MHz.
- Specially designed to control electrical radiator regulation in combination with a Vision® wireless thermostat BT-D03 RF type.
- This couple (Thermostat with smart Plug) can also be managed by a
- Central unit BT-CT02 RF or BT-CT03 RF to have full control of your heating installation from one point.
- Possibility to use the Vision® Smart Plug as light or On/Off control device in combination with a Central unit BT-CT02 RF or BT-CT03 RF.
- Full remote control with the WATTS Vision® Mobile application.
Box contents
Product Description
- Turn ON/OFF the socket LED Blue / Ø
- Device Paring LED flashes Red/Green
- Factory reset LED flashes Green
LED status
-
Flashing Red /Green: Pairing process initiated
-
Flashing
- One Flash red/green/blue: initialization, rebooting
- Green flashing no network connection (2 hours loss) or sensor loss
- Blue flashing over temperature detected
Note: The led is switched off between 8pm and 8am if the plug is associated with a Vision® Centrale Unit or a Vision® wireless programmable thermostats.
Installation
Install and connect the Vision® Smart Plug respecting the fozllowing guidelines to guarantee an optimal reception:
- The Vision® Smart Plug must be mounted at a minimum distance of 50cm of all others wireless materials like GSM, Wi-Fi router.
- Wiring work related to the Vision® Smart Plug must be carried out only when de-energized.
- Connect your Vision® Smart Plug to the power supply.
- Depending on your installation, an installation of a Watts RF repeater paired to the central unit must be required to ensure a correct RF signal transmission
Types of installation
Option 1: Vision® Smart Plug + RF thermostat for heating regulation.
- Switch on the Smart Plug.
- Press the Button during 3 sec to switch to RF Init.
- The LED should be flashing Red /Green indicating that the plug is now in radio configuration mode waiting for a thermostat configuration address.
- Please refer to the thermostat leaflet for enter the thermostat in “RF Init” mode.
- Then The Vision® Smart Plug LED must be switched OFF and the thermostat should exit the RF init mode to indicate correct paring between both elements. You can pair several Vision® Smart Plug to the same RF thermostats.
Option 2: Vision® Smart Plug + RF Thermostat + RF Central unit BT-CT02 RF or BT-CT03 RF for heating regulation and remote control with mobile APP.
- First step is to pair the RF thermostat to the Central unit.
- Press the RF button on the Smart Plug during 3sec.
- The RF LED should be flashing Red /Green indicating that the Smart Plug is now in radio configuration mode waiting for a central configuration address.
- Please refer to the leaflet of the Central unit for more explanation about the pairing mode “RF Init”. You must pair the Smart Plug as a heating device in the Central unit.
- The RF LED on the Smart Plug will switch OFF and the Central will show a message to indicate correct pairing between both elements. You can pair several receivers in the same room.
Option 3: Vision® Smart Plug + RF Central unit BT-CT02 RF or BT-CT03 RF for ON/OFF devices or light control, timer mode and remote control with mobile APP.
- Press the Button 3sec to switch the Smart Plug in RF Init mode.
- The LED should be flashing Red /Green indicating that the Smart Plug is now in radio configuration mode waiting for a central configuration address.
- Please refer to the leaflet of the Central unit for more explanation about the pairing mode “RF Init”. You must pair the Receiver as an ON/OFF plug or a light in the Central unit.
- The LED on the Smart Plug will switch OFF and the Central will show a message to indicate correct pairing between both elements. You can pair several receivers in the same room. Receiver will work in Timer mode; you have the possibility to create a weekly program for ON/OFF period.
Note for installations 2 and 3
- You can pair several receivers. Pay attention! Before linking a new receiver with the Central unit, you have to reset the receiver imperatively.
- In case of a thermostat in RF Alarm, the Smart Plug stops heating.
Compatible thermostats
Technical Characteristics
Environment: Operating temperature
Shipping and storage temperature Thermal safety temperature (relay opening)
| ****
0°C to 40°C
-10°C to +50°C
When > 85°C (back to standard mode when < 65°C)
---|---
Power supply| 230VAC 50Hz with European plug socket
Electrical protection| Cat. II – IP20
Output
Maximum Résistive Load Relay
| Relay 10 A Max 230V 50Hz
Radio Frequency & RF Receiving distance| 868,3 MHz < 10mW (Bidirectional
communication) 30m in residential environment (100m in open field)
EU declaration of conformity Hereby, Watts Electronics declares that the equipment is in compliance with the relevant
Community harmonization legislation
| Low voltage (LVD) – Directive 2014/35/EU Electromagnetic compatibility (EMC) – Directive 2014/30/EU
Radio equipment – Directive 2014/53/EU Restriction of the use of certain hazardous substances (RoHS)
– Directive 2011/65/EU
The full text of the EU declaration of conformity is available on wattswater.eu
Product is in compliance with Classification Contribution| UE 811/2013 and 2010/30/UE IV
2%
Dimensions
Contact
Watts Electronics S.A.S
- B.P. N°10 – Z.A. des Tourettes, 43800 ROSIERES, France
- T: +33(0) 471 57 40 49,
- F: +33(0) 471 57 40 90,
- www.wattswater.eu
- Watts contacts in Europe: https://wattswater.eu/watts/contacts/
© 2023 Watts
References
- HOME
- Home | Watts Europe
- HOME
- Home | Watts Europe
- WATTS EUROPE
- Smart Home and Controls | WATTS EUROPE
- Smart plug PR03 RF 230V
- WATTS Companies in Europe
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>