beamZ Pro IGNITE400 LED 400W BSW Moving Head with CMY 2pcs in Flightcase User Manual
- June 13, 2024
- beamz Pro
Table of Contents
beamZ Pro IGNITE400 LED 400W BSW Moving Head with CMY 2pcs in Flightcase
User Manual
SAFETY INSTRUCTIONS
Warning:
Before carrying out any operations with the unit, carefully read this
instruction manual and keep it with care for future reference. It contains
important information about the installation, usage and maintenance of the
unit.
- Unpack and check carefully that there is no transportation damage before using the unit
- Please read these instructions carefully and follow the instructions.
- Observe all safety warnings. Never remove safety warnings or other information from the equipment.
- Be sure that no ventilation slots are blocked; otherwise the unit will overheated.
Warning:
Before connecting the equipment to the power outlet, first verify that the
mains voltage and frequency match the values specified on the equipment. If
the equipment has a voltage selection switch, connect the equipment to the
power outlet only if the equipment values and the mains power values match. If
the included power cord or power adapter does not fit in your wall outlet,
contact your electrician.
- After connecting the unit, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards.
- Make sure that the power cord is never crimped or damaged. Check the unit and the power cord from time to time.
- Always disconnect power from the mains, when unit is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
- Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
- Do not switch the unit on and off in short intervals.
- Do not connect the unit to a dimmerpack.
- Install the unit in a well ventilated place.
- Never place any material over the lens.
- Never let the sunlight lights directly to the front lens , even when the unit is not working.
- Always allow free air space of at least 50 cm around the unit for ventilation.
- Make sure that the area below the installation place is blocked when rigging, derigging or servicing the unit.
- For mounting height >100 cm, always fix the unit with an appropriate safety-rope. Fix the safety rope at the correct fixation points only. The safety-rope must never be fixed at the transport handles!
- Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
- This unit is not designed for permanent operation. Consistent operation breaks will ensure that the unit will serve you for a long time without defects.
Warning:
If the power cord of the unit is equipped with an earthing contact, then it
must be connected to an outlet with a protective ground. Never deactivate the
protective ground of a power cord
- Make sure that the unit is not exposed to extreme heat, moisture or dust.
- Clean the unit using a dry cloth.
- Do not touch the unit bare-handed during its operation (housing becomes very hot). Allow the unit to cool for at least 5 minutes before handling.
- This unit is designed exclusively for indoor use, do not use this equipment in the immediate vicinity of fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, fluids or gases.
- If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
- Never attempt to bypass the thermostatic switch or fuses.
- Do not dismantle or modify the unit.
- For replacement use fuses/bulb of same type and rating only.
- Repairs, servicing and electric connection must be carried out by a qualified technician.
- The ambient temperature must always be between -5° C and +45° C.
- If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
- Plastic bags must be kept out of reach of children.
- Unit must be installed out of the reach of children. Never leave the unit running unattended.
This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product.
UNPACKING INSTRUCTION
Caution:
Immediately upon receiving the product, carefully unpack the carton, check the
contents to ensure that all parts are present, and have been received in good
condition. Notify the shipper immediately and retain packing material for
inspection if any parts appear damage from shipping or the package itself
shows signs of mishandling. Save the package and all packing materials. In the
event that the product must be returned to the factory, it is important that
the product be returned in the original factory box and packing.
If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
POWER SUPPLY
The label on the backside of the unit indicates the mains voltage to which it must be connected. Check that the mains voltage corresponds to this. Any other voltage than the one indicated may cause irreparable damage to the unit. The unit must also be connected directly to the mains voltage and no dimmer or adjustable power supply may be used.
The unit has a powerconnector output on board. Depending on the local conditions several units can be linked by powerconnector in- and output. Connect a maximum of four (when using 230V/16A) units in a row. Use an approved three-core cable with a cross-section of at least 1.5 mm². The installation instructions of the manufacturer and the colour coding of the cable must be observed. Do not turn off the unit by turning the powerconnector but use the power on/off switch or schuko!
Warning:
Always connect the unit to a protected circuit (circuit breaker or fuse). Make
sure the unit has an appropriate electrical ground to avoid the risk of
electrocution or fire.
RIGGING
The unit may be set up on a stable and even surface. By means of the fixing facilities of the baseplate, the unit can also be mounted upside down to a truss, see below picture. For fixing, certified clamps with correct save working load are required. According to the figure, the quick lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit’s weight. Secure the unit with a safety cable so that it cannot fall down.
When carrying out any installation, always comply European and national
guidelines concerning rigging, truss and all other safety issues. Always let
the installation checked out by an authorized dealer !
DMX512 CONTROL
If you are using a standard DMX controller, you can connect the DMX output of
the controller directly to the DMX input of the first unit in a DMX chain.
Always connect the output of one unit with the input of the next unit until
all units are connected.
Caution:
At the last unit, you must close the DMX line with a terminating resistor.
Take an XLR connector and solder a 120 Ohm resistor between signal (-) and
signal (+) and connect it to the DMX output of the last unit in the line.
RDM CONTROL
This unit can communicate using RDM (Remote Device Management) via DMX512. RDM is a bi directional communication protocol for use in DMX512 control systems, it is the open standard for DMX512 configuration and status monitoring.
The RDM protocol allows data packets to be inserted into a DMX512 line without affecting the existing non-RDM equipment. The system allows a controller or special RDM controller to send and receive commands from specific fixtures.
The RDM function allows you, for example to remotely set the DMX start address of your fixtures. This is especially useful when the fixture is installed in an inaccessible location. Each unit has an RDM UID (unique identification number).
TRANSPORT SECURITY
The unit is equipped with Pan/Tilt lock to prevent damage during transport.
Warning:
Pan/Tilt transport protection must be unlocked before the unit will be into
use!
Lock the unit by sliding the lock pin to the left (horizontally) for Pan or up ( vertically) for Tilt.
Unlock the unit by sliding the lock pin to the right (horizontally) for Pan or down ( vertically) for Tilt.
EXCHANGING GOBOS
Warning:
Turn the unit off, disconnect mains power supply and let the unit cool down
sufficiently before you will start with inserting or exchanging gobo’s .
If you wish to use other patterns as the standard-gobos, make sure that the gobo which you want to insert or exchange has exactly the same size, please follow the instructions below:
-
Remove the spring with an appropriate tool.
Remove the gobo and insert the new gobo. -
Press the spring together and insert it in front of the gobo.
Glass Gobo
Coated glass gobos are inserted with the coating against the rim of the holder
(away from the spring). Textured gobo’s are inserted with the smooth side
against the spring.
**Gobo Dimension
**
Outer Diameter (O.D) : 15.8mm
Image Diameter (I.D) : 12mm
Max. thickness : 1.1 mm
CLEANING
The buildup of dust, dirt and other airborne particles will reduce the unit’s light output. It will also prevent the unit from cooling correctly, and this will reduce the unit’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc. The unit’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase the tendency for dirt to clog.
To get the best performance and lifetime from the unit, inspect it regularly and clean it as soon as you see signs of dirt buildup.
Assess the operating environment each time you begin to use the unit. In dusty or smoky conditions, inspect the unit after a few hours and check it frequently the unit may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.
Use the following guidelines:
- Disconnect the unit from power and allow it to cool completely before cleaning.
- Do not use solvents, abrasives or any other aggressive product to clean the unit.
- Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
- Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and
value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
MAINTENANCE
This unit is virtually maintenance-free, but you should check the unit regularly for mechanical and electrical aspects.
Assess the operating environment and establish an inspection and cleaning schedule that follows the guidelines below:
- Disconnect the unit from the power supply and allow it to cool completely before inspecting and cleaning.
- Check that the screws and bolts used to install the unit are securely tightened and free from corrosion.
- Check the housing, fixing points and installation points, they must not show any signs of deformation, wear or fatigue.
- Check the mechanically moving parts, these must not show any signs of wear or fatigue.
- Check the electrical power and signal cables, they must not show any damage or fatigue.
- Do not use solvents, abrasives or other aggressive products to clean the unit.
- Wipe the unit and clean the glass plate with a soft, clean, lint-free cloth moistened with a weak cleaning solution. Place the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit, connectors and contacts with a soft, clean, lint-free cloth or low-pressure compressed air before re-powering the unit.
TROUBLE SHOOTING
The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:
SYMPTOM | POSSIBLE CAUSE | SUGGESTED ACTION |
---|---|---|
No response from unit. | No power to unitFuse blown or internal fault | Check |
that power is turned on.Check cables and connections.Replace mean fuse or
contact Beamz support or Beamz authorized service partner. Do not remove base
or yoke covers. Do not attempt to replace a fuse or carry out any repairs or
service that are not described in this User Manual unless you have both
authorization from Beamz support or Beamz authorized service partner.
Unit resets correctly but does not respond for does not respond correctly) to
the controller.| The controller is not connected. Bad OMX-line.DMX-line has no
end resistance.Incorrect unit addressing.A unit is defective and is disturbing
data transmission on the DMX-line.Pin 2 and 3 are reversed in XLR connection.|
Connect controller.Inspect connections and cables. Correct poor connections.
Repair or replace damaged cables. Insert DMX terminator plug in DMX output
socket of last unit on DMX-line.Check unit address and DMX mode settings.
Unplug DMX IN and OUT connectors and connect them directly together to bypass
one unit at a time until normal operation is regained. Have defective unit
serviced by an authorized technician.Inspect connections and cables. Install a
phase-reversing cable between the units or swap pin 2 and 3 in the unit that
behaves erratically.
Error after unit reset| Effect requires mechanical adjustment| Check unit’s
software version and errormessages for more information. Contact Beamz support
or Beamz authorized service partner.
Light output cuts out intermittently.| Unit too hot.LEDs damaged.The power
supply settings do not match local AC voltage andfrequency.| Allow unit to
cool. Reduce ambienttemperature. Ensure free airflow around unit. Clean unit
if necessary.Disconnect unit and contact Beamz support or Beamz authorized
service partner.Disconnect unit. Check settings andcorrect if necessary.
Pan| 000-255| Pan
---|---|---
Pan fine| 000-255| Pan fine
Tilt| 000-255| Tilt
Tilt fine| 000-255| Tilt fine
Speed| 000-255| P/t speed
Macro function| 000-199| Reserve
200-209| Xy reset
210-219| Effect reset
220-229| All reset
230-255| Reserve
Shutter| 000-003| Closed
004-103| Strobe slow to fast
104-107| Open
108-207| Invert strobe slow to fast
208-212| Open
213-251| Random strobe slow – fast
252-255| Open
Dimmer| 000-255| Master dimmer
Cmy-c| 000-255| Linear cyaan
Cmy-m| 000-255| Linear magenta
Cmy-y| 000-255| Linear yellow
Cto| 000-255| Linear CTO
Color wheel| 000-004| White
| 005-009| White+ Color 1
010-014| Color 1
015-019| Color 1+ Color 2
020-024| Color 2
025-029| Color 2 + Color 3
030-034| Color 3
035-039| Color 3 + Color 4
040-044| Color 4
045-049| Color 4 + Color 5
| 050-054| Color 5
055-059| Color 5 + Color 6
060-064| Color 6
065-069| Color 6 + Color 7
070-074| Color 7
075-079| Color 7 + Color 8
080-084| Color 8
085-089| Color 8 + Color 9
090-170| Fast rotation – slow rotation
171-174| Stop
175-255| Slow rotation – fast rotation
Gobo wheel 1| 000-009| White1
010-019| White2
020-029| Gobo 1
| 030-039| Gobo 2
040-049| Gobo 3
070-079| Gobo 6
080-089| Gobo 7
090-099| Gobo 8
100-109| Gobo 9
110-119| Gobo 1 jitter
120-129| Gobo 2 jitter
130-139| Gobo 3 jitter
140-149| Gobo 4 jitter
150-159| Gobo 5 jitter
160-169| Gobo 6 jitter
170-179| Gobo 7 jitter
180-189| Gobo 8 jitter
190-199| Gobo 9 jitter
200-225| Fast rotation – slow rotation
226-229| Stop
230-255| Slow rotation – fast rotation
000-009| White
010-019| Gobo 2 -1
020-029| Gobo 2 -2
030-039| Gobo 2 -3
040-049| Gobo 2 -4
050-059| Gobo 2 -5
060-069| Gobo 2 -6
070-079| Gobo 2 -7
080-089| Gobo 2 -8
Gobo wheel 2| 090-099| Gobo 2 -1 jitter
100-109| Gobo 2 -2 jitter
110-119| Gobo 2 -3 jitter
120-129| Gobo 2 -4 jitter
130-139| Gobo 2 -5 jitter
140-149| Gobo 2 -6 jitter
150-159| Gobo 2 -7 jitter
160-169| Gobo 2 -8 jitter
170-213| Fast rotation – slow rotation
214-255| Slow rotation – fast rotation
000-127| Linear
191-192| Stop
193-255| Slow rotation – fast rotation
Prisma 1| 000-255| Prism-1
Prisma/ rotating| 000-127| Rotation
| 128-189| Fast rotation – slow rotation
190-192| Stop
193-255| Slow rotation – fast rotation
Prisma 2| 000-255| Prism-2
Prisma/ rotating| 000-127| Rotation
128-189| Fast rotation – slow rotation
190-192| Stop
193-255| Slow rotation – fast rotation
Frost| 000-127| Reserve
128-255| Frost
000-255| Focus fine
000 -255| Linear zoom
000 -255| Zoom fine
TECHNICAL SPECIFICATION
Colour temperature 6700K
Light source Single colour LED
LED colours White
LED power 400W
Quantity of LEDs 1
Colour wheel 8 colours + open
CMY Wheel Yes
Beam angle: Min 2°
Beam angle: Max 38°
Zoom Yes
Illuminance 209.026 lx @ 1m
Head movement: Pan 540°
Head movement: Tilt 270°
Static gobo: Quantity 10
Rotating gobos: Quantity 8
Interchangeable gobos Yes
Prisma 1 3 Facet
Prisma 2 4 Facet
Frost filter Yes
Flash rate per second 0 – 30Hz
Modes Automatic programs, DMX, Master/Slave
Sound to light mode Yes
RDM Yes
DMX channels 25
DMX connector 3-pin XLR, 5-pin XLR
Display LCD
IP rating IP20
Cooling Temperature controlled fan
Power plug Power-connector
Power consumption 4.13 – 1.95A
Power supply 100-240VAC 50/60Hz
Dimensions (L x W x H) 660 x 360 x 370mm
Weight 20,60
Accessories Mounting bracket, Power cable
+offers a wide range of high performance lighting equipment and related accessories for the rental, entertainment and architectural lighting markets. BeamZ Pro stands for performance, innovation and value pricing!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>