beamZ LCB99 LED Bar 2 In 1 Effect RGBW and UV Light User Manual
- June 13, 2024
- beamZ
Table of Contents
LCB99 LED BAR
BEAMZ MADE EASY
USER MANUAL
SAFETY INSTRUCTIONS
WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with care for future reference. It contains important information about the installation, usage and maintenance of the unit.
- Unpack and check carefully that there is no transportation damage before using the unit
- Please read these instructions carefully and follow the instructions.
- Observe all safety warnings. Never remove safety warnings or other information from the equipment.
- Be sure that no ventilation slots are blocked; otherwise the unit will overheated.
WARNING! Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician.
- After connecting the unit, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards.
- Make sure that the power cord is never crimped or damaged. Check the unit and the power cord from time to time.
- Always disconnect power from the mains, when unit is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
- Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
- Do not switch the unit on and off in short intervals.
- Do not connect the unit to a dimmerpack.
- Install the unit in a well ventilated place.
- Never place any material over the lens.
- Never let the sunlight lights directly to the front lens , even when the unit is not working.
- Always allow free air space of at least 50 cm around the unit for ventilation.
- Make sure that the area below the installation place is blocked when rigging, derigging or servicing the unit.
- For mounting height >100 cm, always fix the unit with an appropriate safety-rope. Fix the safety-rope at the correct fixation points only. The safety-rope must never be fixed at the transport handles!
- Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
- This unit is not designed for permanent operation. Consistent operation breaks will ensure that the unit will serve you for a long time without defects.
WARNING! If the power cord of the unit is equipped with an earthing
contact, then it must be connected to an outlet with a protective ground.
Never deactivate the protective ground of a power cord.
- Make sure that the unit is not exposed to extreme heat, moisture or dust.
- Clean the unit using a dry cloth.
- Do not touch the unit bare-handed during its operation (housing becomes very hot). Allow the unit to cool for at least 5 minutes before handling.
- This unit is designed exclusively for indoor use, do not use this equipment in the immediate vicinity of fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, fluids or gases.
- If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
- Never attempt to bypass the thermostatic switch or fuses.
- Do not dismantle or modify the unit.
- For replacement use fuses/bulb of same type and rating only.
- Repairs, servicing and electric connection must be carried out by a qualified technician.
- The ambient temperature must always be between -5° C and +45° C.
- If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
- Plastic bags must be kept out of reach of children.
- Unit must be installed out of the reach of children. Never leave the unit running unattended.
**** This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service or the shop where you purchased the product.
UNPACKING INSTRUCTION
CAUTION! Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing materials. In the event that the product must be returned to the factory, it is important that the product be returned in the original factory box and packing.
If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
POWER SUPPLY
On the label on the backside of the unit is indicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be used. No dimmer or adjustable power supply.
WARNING! Always connect the unit to a protected circuit (circuit breaker or fuse). Make sure the unit has an appropriate electrical ground to avoid the risk of electrocution or fire.
RIGGING
The unit may be set up on a stable and even surface. By means of the fixing
facilities of the baseplate, the unit can also be mounted upside down to a
truss, see below picture. For fixing, certified clamps with correct save
working load are required. According to the figure, the quick lock bolts of
the omega brackets are placed into the openings provided in the base plate and
turned clockwise until they lock (to the stop). The mounting place must be of
sufficient stability and be able to support a weight of 10 times of the
unit’s weight. Secure the unit with a safety cable so that it cannot fall
down.
When carrying out any installation, always comply European and national
guidelines concerning rigging, truss and all other safety issues. Always let
the installation checked out by an authorized dealer !
DMX512 CONTROL
If you are using a standard DMX controller, you can connect the DMX output of
the controller directly to the DMX input of the first unit in a DMX chain.
Always connect the output of one unit with the input of the next unit until
all units are connected. ![beamZ LCB99 LED Bar 2 In 1 Effect RGBW and UV Light
- DMX controller](https://manuals.plus/wp-content/uploads/2023/08/beamZ-LCB99 -LED-Bar-2-In-1-Effect-RGBW-and-UV-Light-DMX-controller.png)
CAUTION! At the last unit, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor between signal (-) and signal (+) and connect it to the DMX output of the last unit in the line.
CLEANING
The buildup of dust, dirt and other airborne particles will reduce the unit’s
light output. It will also prevent the unit from cooling correctly, and this
will reduce the unit’s lifetime. The rate of dirt buildup will vary depending
on environmental factors such as airborne dust, use of smoke machines,
airflow from ventilation systems, etc. The unit’s cooling fans will accelerate
buildup, and any smoke particles that are present in the atmosphere will
increase the tendency for dirt to clog.
To get the best performance and lifetime from the unit, inspect it regularly
and clean it as soon as you see signs of dirt buildup.
Assess the operating environment each time you begin to use the unit. In dusty
or smoky conditions, inspect the unit after a few hours and check it
frequently the unit may attract dirt faster than you expect. Draw up a
cleaning schedule that will make sure that dirt is removed before it can
build up.
Use the following guidelines:
- Disconnect the unit from power and allow it to cool completely before cleaning.
- Do not use solvents, abrasives or any other aggressive product to clean the unit.
- Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
- Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.
REPLACING THE FUSE
If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuse holder.
Step 3: Install the new fuse in the fuse holder.
Step 4: Replace the fuse holder in the housing.
TROUBLE SHOOTING
The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:
SYMPTOM | POSSIBLE | SUGGESTED ACTION |
---|---|---|
No response from unit. | No power to unit. | |
Fuse blown or internal fault. | Check that power is turned on. |
Check cables and connections.
Replace mean fuse or contact Beamz support or Beamz authorized service
partner. Do not remove base or yoke covers. Do not attempt to replace a fuse
or carry out any repairs or service that are not described in this User Manual
unless you have both authorization from Beamz support or Beamz authorized
service partner.
Unit resets correctly but does not respond (or does not respond correctly) to
the controller.| The controller is not connected.
Bad DMX-line.
DMX-line has no end resistance.
Incorrect unit addressing.
A unit is defective and is disturbing data transmission on the DMX-line.
Pin 2 and 3 are reversed in XLR connection.| Connect controller.
Inspect connections and cables. Correct poor connections. Repair or replace
damaged cables.
Insert DMX terminator plug in DMX output socket of last unit on DMX-line.
Check unit address and DMX mode settings.
Unplug DMX IN and OUT connectors and connect them directly together to bypass
one unit at a time until normal operation is regained.
Have defective unit serviced by an authorized technician.
Inspect connections and cables. Install a phasereversing cable between the
units or swap pin 2 and 3 in the unit, that behaves erratically.
Error after unit reset.| Effect requires mechanical adjustment.| Check unit’s
software version and error messages for more information. Contact Beamz
support or Beamz authorized service partner.
Light output cuts out intermittently.| Unit too hot.
LEDs damaged.
The power supply settings do not match local AC voltage and frequency.| Allow
unit to cool. Reduce ambient temperature. Ensure free airflow around unit.
Clean unit if necessary.
Disconnect unit and contact Beamz support or Beamz authorized service
partner.
Disconnect unit. Check settings and correct if necessary.
CONTROL MENU
MENU | DESCRIPTION | |
---|---|---|
DMX | A001-Axxx | Auto-run mode |
AUTO | Au1-32 | Pre program |
HOPPING | FF01-99 | Program with hopping effect |
FADE | CC01-99 | Program with fade effect |
JUMP | EE01-99 | Program with jump effect |
STROBE | F000-255 | Strobe from slow to fast |
COLOUR | r000-255 | Red manual adjustment |
g000-255 | Green manual adjustment | |
b000-255 | Blue manual adjustment | |
u000-255 | White manual adjustment | |
1000-255 | UV manual adjustment | |
AUTO Auto | Auto run | |
SOUND SOUD | uoL1-9 | Sound sensitivity adjustment |
bAon / bAof | Sound mode on/off |
DMX CHANNELS
CHANNEL | FUNCTION | VALUE | DESCRIPTION |
---|---|---|---|
1 | Master dimmer | 000-255 | Dimming 0-100% |
2 | Colour | 000-255 | Red, 0-100% |
3 | 000-255 | Green, 0-100% | |
4 | 000-255 | Blue, 0-100% | |
5 | 000-255 | White, 0-100% | |
6 | 000-255 | UV, 0-100% | |
7 Strobe | 000-009 | No function | |
010-255 | Strobe, slow to fast ( CH1 must be on and select the colour CH2 till |
CH6)
8 Mode| 000-010| No function
011-070| Program with hopping effect
071-130| Program with fade effect
131-190| Program with pulse effect
191-255| Sound mode
TECHNICAL SPECIFICATIONS
Rated voltage | : 100-240VAC, 50-60Hz, 0.3-0.1A |
---|---|
LED | : 9x 6 Watt 4-in-1 LED + 9x 3Watt UV LEDs |
Flash rate | : 1-22 Hz |
Fuse | : F3A |
DMX Channels | : 8 |
Functions | : DMX, Automatic programs, Sound to light and Master-Slave. |
Dimensions per unit | : 380 x 130 x 80mm |
Weight (per unit) | : 1.45kg |
Design and product specifications are subject to change without prior notice.
European Union
Tronios B.V.,
Bedrijvenpark Twente Noord 18,
7602KR Almelo, The Netherlands
2014/35/EU
2014/30/EU
2011/65/EC
United Kingdom
Tronios Ltd.,
130 Harley Street,
London W1G 7JU, United Kingdom
S.I. 2016:1101
S.I. 2016:1091
S.I. 2012:3032
is a leading developer of lighting products, including intelligent DMX moving heads, wireless battery operated DMX effects, static washes, sound-activated club effects, strobes & blacklights, LED lighting, fog and special effects machines, lasers and indoor and outdoor architectural lighting, as well as lighting controllers and protective bags.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>