519125 Highbond Anker Dynamic FHB dyn
Product Information
The FIS HB 360 S is a high-strength injection mortar used for anchoring the FHB-A dyn highborn anchor rod. It is suitable for use in concrete and masonry.
The FHB-A dyn anchor rod can only be used with the FIS HB 360 S or FIS HB 150 C injection mortar.
The product comes with installation instructions in multiple languages: German (DE), English (EN), Chinese (ZH), French (FR), Italian (IT), Dutch (NL), Polish (PL), Russian (RU), Czech (CS), Slovak (SK), Spanish (ES), and Portuguese (PT).
Product Usage Instructions
-
Drill and clean the hole using a hammer drill. Ensure that the drill hole diameter and depth comply with the values specified in Table 2 of the user manual. Clean the drill hole thoroughly,
starting from the bottom, blow the drill hole clear at least twice, brush it twice, then blow it clear two more times. For required brushes (BS), see Table -
For thread sizes M20 and higher, the drill hole must be blown clear with oil-free pressurized air (at least 6 bar), using an ABP pressurized air cleaning gun and the appropriate blowout nozzle (item no. 59456). Insufficient cleaning can reduce bearing capacity.
-
Prepare the FIS HB injection mortar by unscrewing the cap, attaching the static mixer, and inserting the mortar cartridge into the fischer application gun. Squeeze out mortar until it is an even grey color when it leaves the gun. Mortar that is not grey does not set and must be discarded (approx. 2 gun strokes). Never use without the static mixer.
-
Install the pre-fixing anchor by filling in the drill hole with FIS HB injection mortar starting from the bottom, one shot at a time (avoid air pockets). Fill quantity is approximately 2/3 of the drill hole depth (for fill quantity, see Table 2). Allow injection mortar to harden according to the hardening times specified in Table 1.
-
Fill the annular gap by completely filling the annular gap between the anchor rod and the attached component with mortar using the drill hole in the conical seat. To do this, put the adapter (C) on the static mixer. You can know that the annular gap is completely full if the filling device (adapter) is pressed out of the filling hole in the conical seat or if mortar exits between the attached component and the concrete surface.
FIS HB 360 S
Art. No. 519125 (DE)
Art. No. 562658 (EN, ZH)
Art. No. 562659 (DE, FR, IT, NL)
Art. No. 562660 (EN, PL, RU, CS, SK)
Art. No. 562661 (EN, ES, PT, EL)
Installation Instructions
fischer highbond anchor dynamic FHB dyn
Pre-fixing installation
Consisting of:
-
fischer highbond injection mortar FIS HB 360 S resp.
FIS HB 150 C -
fischer highbond anchor rod FHB-A dyn
The fischer highbond anchor rod FHB-A dyn may only be used in conjunction with fischer injection mortar FIS HB 360 S resp. FIS HB 150 C.
-
Drill and clean hole
Drill a cylindrical hole using a hammer drill. Ensure that the drill hole diameter and depth comply with the values specified in Table 2.
Clean drill hole thoroughly:
Starting from the bottom, blow the drill hole clear at least twice, brush it twice, then blow it clear two more times. For required brushes (BS), see Table -
For thread sizes M20 and higher, the drill hole must be blown clear with oil free pressurized air (at least 6 bar), using an ABP pressurized air cleaning gun and the appropriate blowout nozzle (item no. 59456).
Insufficient cleaning = reduced bearing capacity.
Drilling with a hollow drill:
When using hollow drills with suction, there is no need to clean the drill hole. required. -
Prepare FIS HB injection mortar
Unscrew the cap. Attach the static mixer. The spiral mixer in the static mixer must be clearly visible. Insert the mortar cartridge into the fischer applica- tion gun. Squeeze out mortar until it is an even grey colour when it leaves the gun.
Mortar that is not grey does not set and must be discarded (approx. 2 gun strokes). Never use without the static mixer. -
Install the pre-fixing anchor
Fill in the drill hole with FIS HB injection mortar starting from the bottom, one shot at a time (avoid air pockets). Fill quantity is approx. 2/3 of the drill hole depth (for fill quantity, see Table 2). Set anchor rod:
Press in the anchor rod (without nuts, washers or centering sleeve), turning it slightly. Observe the minimum projection length, hP (see Table 2). – The annular gap between the anchor rod and the drill hole wall must be filled with mortar completely. If this is not the case, the anchor rod must be immediately removed and injection mortar must be injected in the drill hole again. Remove excess mortar.
Allow injection mortar to harden:
For the hardening times of tcure injection mortar, see Table 1.
Attach the component and install the washers and nuts as shown in (A) resp. (B) (2 possible variants) – the plastic nozzle is not required !
Tighten the hexagonal nut with installation torque Tinst (see Table 2). Tighten counter nut manually, then use a wrench to give it another quarter or half turn. In the highly corrosion-resistant stainless steel version, the counter nut is a thin nut. Tighten it with a torque of ¼ Tinst. -
Fill the annular gap
Completely fill the annular gap between the anchor rod and the attached component with mortar using the drill hole in the conical seat. To do this, put the adapter (C) on the static mixer. You can know that the annular gap is completely full if the filling device (adapter) is pressed out of the filling hole in the conical seat or if mortar exits between the attached component and the concrete surface.
Table 1: Processing and setting time
Temperature of cartridge* °C| Open time/ setting time Min.| | Temperature in
the keying surface °C| Setting time** Min.
---|---|---|---|---
| | | – 5 to ± 0| 360
| | | +1 to + 5| 180
+5| 15| | +6 to + 10| 90
+20| 6| | +11 to + 20| 35
+30| 4| | +21 to + 30| 20
+40| 2| | + 31 to + 40| 12
- The temperature of the cartridge must not fall below + 5 °C.
For damp surfaces, waiting times must be doubled. Table 2**
Highbond-Anker FHB-A dyn| hef [mm]| tfix [mm]| hp [mm]| do [mm]| ho [mm]| df
[mm]| Tinst [Nm]| | |
---|---|---|---|---|---|---|---|---|---|---
12 x 100/25| 100| 8–25| 30 + tfix| 14| 130 – tfix| 15| 40| 6| 19| BS 14
12 x 100/50| 100| 8–50| 30 + tfix| 14| 155 – tfix| 15| 40| 7| 19| BS 14
16 x 125/25| 125| 10–25| 35 + tfix| 18| 155 – tfix| 19| 60| 8| 24| BS 16/18
16 x 125/50| 125| 10–50| 35 + tfix| 18| 180 – tfix| 19| 60| 9| 24| BS 16/18
16 x 125/75| 125| 10–75| 35 + tfix| 18| 205 – tfix| 19| 60| 11| 24| BS 16/18
16 x 125/80| 125| 10–80| 35 + tfix| 18| 210 – tfix| 19| 60| 11| 24| BS 16/18
16 x 125/100| 125| 10–100| 35 + tfix| 18| 230 – tfix| 19| 60| 12| 24| BS 16/18
16 x 125/125| 125| 10–125| 35 + tfix| 18| 255 – tfix| 19| 60| 13| 24| BS 16/18
16 x 125/150| 125| 10–150| 35 + tfix| 18| 280 – tfix| 19| 60| 16| 24| BS 16/18
20 x 170/50| 170| 12–50| 40 + tfix| 24| 225 – tfix| 25| 100| 20| 30| BS 24
24 x 220/50| 220| 14–50| 50 + tfix| 28| 275 – tfix| 29| 120| 38| 36| BS 28
Push-through installation
Consisting of:
-
fischer highbond injection mortar FIS HB 360 S resp.
FIS HB 150 C -
fischer highbond anchor rod FHB-A dyn
The fischer highbond anchor rod FHB-A dyn may only be used in conjunction with fischer injection mortar FIS HB 360 S resp. FIS HB 150 C.
-
Pre-installation, drill and clean hole
Pre-install anchor rod as shown in Figures (A) or (B) (2 possible variants).
(A): Plastic centring sleeve, fillable conical seat, spherical washer, hexagonal nut and counter nut.
(B): Plastic centring sleeve, fillable conical seat, hexagonal nut with ball head and counter nut.
Drill hole: Drill a cylindrical hole through the attached component using a hammer drill. Ensure that the drill hole diameter and depth comply with the values specified in Table 2.
Clean the drill hole thoroughly: Starting from the bottom, blow the drill hole clear at least twice, brush it twice, then blow it clear two more times. For required brushes (BS), see Table 2. For thread sizes M20 and higher, the hole must be blown clear with oil-free pressurized air (at least 6 bar), using an ABP pressurized air cleaning gun and the appropriate blow-out nozzle (item no. 59456). Insufficient cleaning = reduced bearing capacity.
Drilling with a hollow drill:
When using hollow drills with suction, there is no need to clean the drill hole. required -
Prepare FIS HB injection mortar
Unscrew the cap. Attach the static mixer. – The spiral mixer in the static mixer must be clearly visible. Insert the mortar cartridge into the fischer application gun. Squeeze out mortar until it is an even grey colour when it leaves the gun. Mortar that is not grey does not set and must be discarded (approx. 2 gun strokes). Never use without the static mixer. -
Install push-through anchor
The drill hole must be filled through the through hole in the attached component. Fill in the drill hole with FIS HB injection mortar starting from the bottom, one shot at a time (avoid air pockets). Fill quantity approx. ⅔ of the drill hole incl. attached component (for fill quantity, see Table 2).Set anchor rod: Press in the pre-installed anchor rod, turning it slightly, until it
reaches the setting depth. The setting depth is reached when the plastic centring bush penetrates the through bore of the attached component and the filling washer rests on this component with its full surface. Mortaring must reach up to the surface of the attached component. If this is not the case, the anchor rod must be immediately removed and injection mortar must be injected in the drill hole again.
Allow injection mortar to harden:
For the hardening times of structure injection mortar, see Table 1.
Tighten the hexagonal nut with installation torque Tints (see Table 2).
Tighten counter nut manually, then use a wrench to give it another quarter or
half turn.
In the highly corrosion-resistant stainless steel version, the counter nut is
a thin nut.
Tighten this with a torque of ¼ Tints.
Table 1: Processing and setting time
Temperature of cartridge* °C| Open time/ setting time Min.| | Temperature in
the keying surface °C| Setting time** Min.
---|---|---|---|---
| | | – 5 to ± 0| 360
| | | +1 to + 5| 180
+5| 15| | +6 to + 10| 90
+20| 6| | +11 to + 20| 35
+30| 4| | +21 to + 30| 20
+ 40| 2| | + 31 to + 40| 12
- The temperature of the cartridge must not fall below + 5 °C. ** For damp surfaces, waiting times must be doubled.
Table 2
Highbond-Anker| hef| tfix| hp| do| ho| df| Tinst| | | |
---|---|---|---|---|---|---|---|---|---|---|---
FHB-A dyn| [mm]| [mm]| [mm]| [mm]| [mm]| [mm]| [Nm]| | | |
12 x 100/25| 100| 8–25| 30 + tfix| 14| 130 – tfix| 15| 40| 6| | 19| BS 14
12 x 100/50| 100| 8–50| 30 + tfix| 14| 155 – tfix| 15| 40| 7| | 19| BS 14
16 x 125/25| 125| 10–25| 35 + tfix| 18| 155 – tfix| 19| 60| 8| | 24| BS 16/18
16 x 125/50| 125| 10–50| 35 + tfix| 18| 180 – tfix| 19| 60| 9| | 24| BS 16/18
16 x 125/75| 125| 10–75| 35 + tfix| 18| 205 – tfix| 19| 60| 11| | 24| BS 16/18
16 x 125/80| 125| 10–80| 35 + tfix| 18| 210 – tfix| 19| 60| 11| | 24| BS 16/18
16 x 125/100| 125| 10–100| 35 + tfix| 18| 230 – tfix| 19| 60| 12| | 24| BS
16/18
16 x 125/125| 125| 10–125| 35 + tfix| 18| 255 – tfix| 19| 60| 13| | 24| BS
16/18
16 x 125/150| 125| 10–150| 35 + tfix| 18| 280 – tfix| 19| 60| 16| | 24| BS
16/18
20 x 170/50| 170| 12–50| 40 + tfix| 24| 225 – tfix| 25| 100| 20| | 30| BS 24
24 x 220/50| 220| 14–50| 50 + tfix| 28| 275 – tfix| 29| 120| 38| | 36| BS 28
fischerwerke GmbH & Co. KG
KlausFischerStraße 1 · 72178 Waldachtal · Germany Tel. +49 7443 120 · Fax
+49 7443 124222 www.fischer.de
fischer fixing (UK) Ltd
Whitely Road · Wallingford, Oxfordshire · OX10 9AT – United Kingdom Phone +44
1491 827900 · Fax +44 1491 827953
www.fischer.co.uk
fischer Ibérica, S.A.
C/ Klaus Fischer, 1 · 43300 Montroig del Camp / Tarragona · Spain Tel. +34
977 838711 · Fax +34 977 838770 www.fischer.es
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>