Outwell 651185 Akira 300 Power Station Instruction Manual

June 13, 2024
Outwell

Outwell 651185 Akira 300 Power Station

Product Information

The Akira 300 Power Station is a versatile portable power source that offers various outputs to charge and power your devices. It comes with a built-in MPPT controller for solar panels and multiple charging options. The power station has safety features such as short circuit protection, overcharge protection, over discharge protection, overcurrent protection, extreme low power protection, over temperature protection, reverse connection protection, anti-charge protection, and overvoltage protection.

The power station includes the following components:

  1. Power Station
  2. AC adaptor 100-240V AC
  3. Supply cable for AC adaptor, IEC-C
  4. Supply cable for AC adaptor, IEC-G
  5. Cigarette lighter DC cable
  6. IEC-G adapter socket for inverter

The power station has the following outputs:

  • 1 x AC 220V: Pure sine wave inverter. Max 300W continuous load, 450W peak load (max. 10 seconds)
  • 2 x USB A, DC 5V max 12W
  • 1 x USB A QC 3.0, DC 5V/9V max 18W
  • 3 x DC 10.8V max 150W
  • 1 x USB-C / PD max 60W (input/output)
  • 3W dimmable LED lamp

The power station also features a display that shows the battery capacity remaining in percentage, hours remaining until fully charged, and the power (input/output) in watts. It has buttons to control the LED lamp, DC output, USB output, and AC output.

WARNINGS

  1. Please ensure close supervision of any child using the product to reduce risks.
  2. Please keep the product in a dry place to avoid rain − risk of electric shock.
  3. Do not expose product to fire or temperatures above 55°C − risk of explosion.
  4. Store the product in a cool, dry place when not in use.
  5. Do not disassemble the product − risk of fire, explosion, or electric shock.
  6. Do not use the product to jump-start a vehicle.
  7. Please disconnect from power source when not in use.
  8. Do not use the product with damaged input or output cables − risk of electric shock.

PRODUCT CONTENT

Outwell-651185-Akira-300-Power-Station- \(1\)

  1. Power Station

  2. AC adaptor 100-240V AC

  3. Supply cable for AC adaptor, IEC-C

  4. Supply cable for AC adaptor, IEC-G

  5. Cigarette lighter DC cable

  6. IEC-G adapter socket for inverter
    OVERVIEW OF POWER STATIONOutwell-651185-Akira-300-Power-Station-
\(2\)

  7. Input: DC 12-30V max 100W. Built-in MPPT controller for solar panels.

  8. Output: 1 x AC 220V. Pure sine wave inverter. Max 300W continuous load. 450W peak load (max. 10 seconds).

  9. Output: 2 x USB A, DC 5V max 12W

  10. Output: 1 x USB A QC 3.0, DC 5V/9V max 18W

  11. Output: 3 x DC 10.8V max 150W

  12. Input/output: 1 x USB-C / PD max 60W

  13. 3W LED lamp, dimmable
    OVERVIEW OF DISPLAYOutwell-651185-Akira-300-Power-Station-
\(3\)

  14. Battery capacity remaining in percent

  15. Hours remaining

  16. Power (Input/output) in watts

  17. DC output on/off

  18. USB output on/off

  19. AC output on/off
    OVERVIEW OF BUTTONSOutwell-651185-Akira-300-Power-Station-
\(4\)

  20. LED lamp on/off

  21. DC output on/off

  22. USB output on/off

  23. AC output on/off

OPERATION
Outwell Akira power stations are equipped with a comprehensive set of safety features. These include: short circuit, overcharge, over discharge, overcurrent, extreme low power, over temperature, reverse connection, anti- charge and overvoltage protections.

Charging

Ensure the power station is fully charged before first use. Connect the DC input (7) to a power source. The power station is fully charged when the battery capacity display (14) reads 100%. The power station can also be charged via the USB-C/PD port (12). Connect a suitable charger, e.q. a laptop computer charger, with USB-C/PD output to the power station’s USB-C/PD port. The last digit on the battery capacity display will flash to indicate the power station is charging.Outwell-651185-Akira-300-Power-Station-
\(5\)

  • App. charging times from 0 – 100%:
  • AC adaptor (2): 4-6 hours
  • Car charger 12V DC (5): 2-3 hours
  • USB-C/PD: 5-7 hours
  • Solar (120W panel – optional): 3-8 hours depending on weather

The power station has an integral MPPT charge controller for solar charging from optional solar panels with an open circuit voltage up to 30V DC. Example: depending on weather, charge time from 0-100% will be app. 3-8 hours when using a 120W panel. The power display (16) will show the charging power in watts, and the hours remaining display (15) will show the hours remaining until fully charged.

Use

  • To power a device from the power station, use a suitable cord to connect the device and select the desired output circuit on the power station using the buttons (20) – (23). The corresponding icon (14) – (19) on the display will indicate that the selected circuit is active.
  • Multiple circuits and ports can be used to power multiple devices simultaneously.
  • The power display (16) will show the combined power usage of the connected devices in watts, and the hours remaining display (15) will show how many hours of power is left with the current load.
  • The AC output (8) can be used for devices up to 300W continuous load and it can deliver up to 450W for up to 10 seconds. The AC output is pure sine wave and is suitable for all types of electronics.
  • The USB-C/PD port can be used for both input and output. The power station will automatically communicate with the connected device and determine the required voltage and power.
  • The power station supports through charging. This allows the use of power station outputs while the unit is being charged.
  • When the input power (charge) is greater than the output power (connected devices) the power display (16) will show the net input power. Example: if the power station is charged with 80 watt, and the connected devices draws 30 watts, the power display will show 50 watts. The remaining hours display (15) will show how many hours remain until fully charged.
  • When the input power (charge) is less than the output power (connected devices) the power display (16) will show the net power output (consumption), Example: if the power station is charged with 80 watts, and the connected devices draws 120 watt, the power display will show 40 watts. The remaining hours display (15) will show how many hours of power is left with the current load.
  • If in doubt about whether the input power or the output power is greatest, disconnect the charge input briefly and check the power reading (output power) on the display (16). Compare this to the input power, check the display (16) with all outputs turned off briefly (use the buttons (20) – (23).
  • When a circuit is no longer in use, press the button (20) – (23) to switch it off to save power.

Cleaning & maintenance

Visually check the general condition of the power station and its accessories on a regular basis The power station can be cleaned with a damp cloth if necessary.

WARNING: Do not use sharp or hard objects or cleaning agents for cleaning as these may damage the product.

Storage: If the power station is not used for a long time, it should be recharged every 12 months and the battery capacity kept between 60-80%. Store the power station in a cool and dry place.

Faults

The power station has the following protective functions:

  • Short circuit protection
  • Over charge protection
  • Over-discharge protection
  • Over current protection
  • Extreme low power protection
  • Over temperature protection
  • Reverse connection protection
  • Anti-charge protection
  • Over-voltage protection

Overload warning: If any output circuit is being overloaded, e.g. a device drawing more power than the circuit’s rating, the safety shutdown of that circuit will engage. Warning will be in the form of an alarm beep combined with the displayed overload icon.

  • The affected circuit will be shut off. To rectify, unplug the device in question and turn the circuit on again (20) – (23) to use the power station.
    Temperature warning: If the temperature of the inverter or battery cells exceeds its range, the temperature warning icon will be displayed along with an alarm beep, and the power station will shut off. Let the power station cool down before continued use.

  • Integral fans prevent the power station overheating under heavy loads and the fan icon will be displayed when these fans are in action.

  • If you are unable to rectify any fault following the above instructions, contact the dealer or Outwell Customer Service.

Disposal:
Dispose of the power station as battery waste according to local regulations. Do not dispose of any batteries with general household waste.

Light Source: LED
The light source and control gear is not replaceable. Access to light source and control gear brings contact with high voltages and a high risk of electric shock. Making the light source and control gear replaceable would also introduce weak points in the construction that could reduce the lifetime of the product.

Technical data

  • Battery type: Lithium-ion
  • Battery capacity: 281Wh
  • Battery charge cycle life: 1,000 cycles
  • Operation temperature: -20°C – 55°C
  • Charging temperature: 0°C – 45°C
  • AC inverter type: Pure sine wave
  • AC inverter output: 220V 50Hz 300W (450W peak)
  • DC input: 12-30V max 100W
  • Solar controller type: MPPT
  • DC output: 10.8V 10A (x3)
  • USB-C/PD in-/output: 5-20V max 60W
  • USB A output: 5V 2.4A (x2)
  • USB A QC output: 5V 3A, 9V 2A

Outwell Customer Service
e-mail: info@outwell.com
Tel.: +45 70 50 59 00

Outwell® is a reg. trademark of Oase Outdoors
EU: Kornvej 9, DK-7323 Give, Denmark
UK: One Glass Wharf, Bristol, BS2 0ZX

outwell.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals