IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Carbon Monoxide
(CO) Alarm’s operation. If you are installing this CO Alarm for use by others,
you must leave this manual—or a copy of it—with the end user.
INTRODUCTION
BASIC SAFETY INFORMATION
IMPORTANT!
- Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially hazardous situations. Pay special attention to these items.
- THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect carbon monoxide from ANY source of combustion. It is NOT designed to detect smoke, fire, or any other gas.
- This CO Alarm is approved for use in single-family residences. It is NOT designed for marine use.
CAUTION:
- This CO Alarm will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas.
WARNING!
- The Silence Feature is for your convenience only and will not correct a CO problem. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.
- NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to “If Your CO Alarm Sounds” for more information. Failure to do so can result in injury or death.
- Test the CO Alarm once a week. If the CO Alarm ever fails to test correctly, have it replaced immediately! If the CO Alarm is not working properly, it cannot alert you to a problem.
- This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure CO levels in compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards. Individuals with medical conditions that may make them more sensitive to carbon monoxide may consider using warning devices which provide audible and visual signals for carbon monoxide con-centrations under 30 ppm. For additional information on carbon monoxide and your medical condition contact your physician.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that the interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that of the receiver.
- Consult the dealer or an experienced radio or TV technician for help.
Warning: Changes or modifications to the product, not expressly approved
by First Alert / BRK Brands, Inc., could void the user’s authority to operate
the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
HOW YOUR CO ALARM WORKS GENERAL INFORMATION
WARNING
- This CO Alarm does not operate without working batteries.
Removing the batteries, or failure to replace them at the end of their service life, removes your protection.
A CO Alarm measures the CO levels in the air. It will alarm if CO levels rise
quickly (if the heat exchanger on your furnace breaks, for example), or if CO
is consistently present (a slow CO leak on a fuel-burning appliance).
This Carbon Monoxide Alarm features a permanently installed sensor and an 85
dB alarm horn. It also has a silence feature to temporarily quiet the alarm
horn.
THE PARTS OF YOUR CO ALARM
- Open door (in back)
- Battery Compartment (in back)
- Test/Silence Button
- POWER/ALARM Light (RED)
- (Behind Cover) Alarm Horn: 85dB audible alarm for test, alarm, and unit malfunction warning.
UNDERSTANDING YOUR CO ALARM
ALARM RECEIVING BATTERY POWER
Light flashes every minute. Horn is silent.
LOW BATTERY WARNING
The light continues to flash (RED) and the horn also “chirps” once every
minute. This warning should last for up to 7 days, but you should replace the
battery as soon as possible.
DURING TESTING
Light flashes Red in sync with the horn pattern (4 beeps, pause, 4 beeps),
simulating a CO Alarm condition.
CO ALARM
Sensor has detected enough CO to trigger an alarm. Light flashes rapidly and
horn sounds loudly (repeating 4 beeps, pause). See “If Your CO Alarm Sounds”
for details. During an alarm, move everyone to a source of fresh air. DO NOT
move the CO Alarm!
CO ALARM REQUIRES SERVICE (MALFUNCTION SIGNAL)
The light flashes (RED) and the horn sounds 3 “chirps” every minute.
CO Alarm needs to be replaced.
CO ALARM HAS REACHED ITS END OF LIFE
The light flashes (RED) and the horn sounds 5 “chirps” every minute.
CO Alarm needs to be replaced.
INSTALLATION
WHERE TO INSTALL CO ALARMS
The National Fire Protection Association (NFPA) recommends that a CO Alarm
should be centrally located outside of each separate sleeping area in the
immediate vicinity of the bedrooms. For added protection, install additional
CO Alarms in each separate bedroom, and on every level of your home.
If your bedroom hallway is longer than 40 feet (12 meters), install a CO Alarm
at BOTH ends of the hallway.
REQUIRED TO MEET NFPA RECOMMENDATIONS
SUGGESTED AREAS FOR INSTALLING ADDITIONAL CO ALARMS
In a Single-level Home:
-
Install at least one CO Alarm near or within each separate sleeping area.
-
For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
In a Multi-level Home: -
Install at least one CO Alarm near or within each separate sleeping area.
-
For added protection, install at least one CO Alarm on each level of the home.
-
For added protection, install an additional CO Alarm at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
In Mobile Homes: -
Install CO Alarms on inside walls ONLY. Uninsulated outside walls and roofs of mobile homes often transfer heat and cold from outdoors. The Alarm should be located at least 6 inches (152 mm) from all exterior walls and at least 12 inches (305 mm) from supply or return vents.
WHERE CO ALARMS SHOULD NOT BE INSTALLED
DO NOT LOCATE THIS CO ALARM:
- In garages, kitchens, furnace rooms, or in any extremely dusty, dirty or greasy areas.
- Closer than 20 feet (6 meters) from a furnace or other fuel burning heat source, or fuel burning appliances like a water heater.
- Within 5 feet (1.5 meters) of any cooking appliance.
- In extremely humid areas. This alarm should be at least 10 feet (3 meters) from a bath or shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room or other source of high humidity.
- In areas where temperature is colder than 40˚ F (4.4˚ C) or hotter than 100˚ F (37.8˚ C). These areas include unconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.
- In turbulent air, like near ceiling fans, heat vents, air conditioners, fresh air returns, or open windows. Blowing air may prevent CO from reaching the sensors.
- Outside the Mobile Home.
- In direct sunlight.
WARNING
- This CO Alarm is designed for use inside a single-family home or apartment. It is not meant to be used in common lobbies, hallways, or basements of multi-family buildings unless working CO Alarms are also installed in each family living unit. CO Alarms in common areas may not be heard from inside individual family living units.
- This CO Alarm alone is not a suitable substitute for complete detection systems in places which house many people, like hotels or dormitories, unless a CO Alarm is also placed in each unit.
- DO NOT use this CO Alarm in warehouses, industrial or commercial buildings, special-purpose non-residential buildings, or airplanes. This CO Alarm is specifically designed for residential use, and may not provide adequate protection in non-residential applications.
HOW TO INSTALL YOUR CO ALARM
Read “Where To Install Your CO Alarm” before starting.
Before you start installation, find the pair of self-adhesive labels included
with this CO Alarm. On each label write in the phone number of your emergency
responder (like 911) and a qualified appliance technician. Place one label
near the CO Alarm, and the other label in the “fresh air” location you plan to
go if the alarm sounds.
INSTALLING THE 9V BATTERY
-
Push and lift the battery door down to open.
-
Install the 9 volt battery (included) inside the battery compartment as indicated. Make sure the “+” and “–” ends of each battery are aligned properly.
-
Ensure battery is securely snapped into terminals by pushing in direction of arrow in the diagram.
-
Close the battery door.
-
Push and hold the Test/Silence button on the cover until you hear an acknowledge “chirp”. The alarm horn will sound 4 beeps, a pause, then 4 beeps. The ALARM (RED) light will flash. The alarmsequence should last 5-6 seconds. If it does not alarm, make sure the battery is correctly installed, and test it again.
TO MOUNT ON THE WALL
Tools you will need: pencil, drill with 3/16” or 5mm drill bit, flathead
screwdriver, hammer.
- Choose a location on the wall. Do not install the Alarm closer than 4” (102 mm) from where the wall meets the ceiling.
- Hold the mounting guide template against the wall, and make a mark inside each keyhole where you will drill your mounting hole as shown in the diagram below.
- Use a 3/16” (5 mm) drill bit to drill through the marks you made for the mounting holes.
- Insert the plastic screw anchors into the mounting holes until they are flush with the wall. If necessary, tap them gently with a hammer.
- Insert the screws into the anchors until the screwhead is 1/8 inch (3 mm) away from the wall.
- Slide the CO Alarm onto the screws until you feel it click into place.
- Test the CO Alarm as described in “Weekly Testing.”
IF YOUR CO ALARM SOUNDS
WARNING
Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it!
IF THE ALARM SIGNAL SOUNDS:
- Operate the Test/Silence button.
- Call your emergency services, fire department or 911. Write down the number of your local emergency service here:
- Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.
- After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this quipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:
“ALARM-MOVE TO FRESH AIR”
If you hear the alarm horn and the Red light is flashing, move everyone to a
source of fresh air.
DO NOT disconnect the batteries from the CO Alarm!
WARNING
Alarms have various limitations. See “General Limitations of CO Alarms” for
details.
USING THE SILENCE FEATURE
WARNING
- The Silence Feature is for your convenience only and will not correct a CO problem. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.
- NEVER remove the batteries from your CO Alarm to silence the horn. Use the silence feature. Removing the batteries removes your protection! See “If Your CO Alarm Sounds” for details on responding to an alarm.
The Silence Feature is intended to temporarily silence your CO Alarm’s alarm
horn while you correct the problem—it will not correct a CO problem. While the
alarm is silenced it will continue to monitor the air for CO.
When CO reaches alarm levels the alarm will sound— repeating horn pattern: 4
beeps, a pause, 4 beeps, etc. Press and hold the Test/ Silence button until
the horn is silent. The initial Silence cycle will last approximately 4
minutes.
NOTE: After initial 4-minute Silence cycle, the CO Alarm re-evaluates
present CO levels and responds accordingly. If CO levels remain potentially
dangerous—or start rising higher—the horn will start sounding again.
While the detector is silenced:
If the CO Alarm…
Is silent for only 4 minutes, then starts sounding loudly—4 beeps, pause, 4
beeps, pause| This means…
CO levels are still potentially dangerous.
---|---
If the CO Alarm…
Remains silent after you pressed the Test/Silence button| This means…
CO levels are dropping.
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning “chirp” for
up to 8 hours. You can silence the low battery warning “chirp” by pressing the
Test/Silence button. Activation of low battery silence is acknowledged with a
“chirp”.
After 8 hours, the low battery “chirp” will resume. Replace the batteries as
soon as possible; this unit will not operate without battery power!
If you cannot silence the low battery warning, replace the batteries
immediately.
SILENCING THE END OF LIFE SIGNAL
This silence feature can temporarily quiet the End of Life warning “chirp” for
up to 2 days. You can silence the End of Life warning “chirp” by pressing the
Test/Silence button. The horn will chirp, acknowledging that the End of Life
silence feature has been activated. After approximately 2 days, the End of
Life “chirp” will resume.
TESTING & MAINTENANCE
WEEKLY TESTING
WARNING
- Test the CO Alarm once a week. If the CO Alarm ever fails to test correctly, have it replaced immediately! If the CO Alarm isnot working properly, it cannot alert you to a problem.
- DO NOT stand close to the Alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When testing, step away when horn starts sounding.
Push and hold the Test/Silence button on the cover until you hear an
acknowledge “chirp”. The alarm horn will sound 4 beeps, a pause, then 4 beeps.
The ALARM (RED) light will flash.
The alarm sequence should last 5-6 seconds. If it does not alarm, make sure
fresh batteries are correctly installed, and test it again. If the unit still
does not alarm, replace it immediately.
If the alarm does not test properly:
- Make sure that fresh batteries are installed correctly.
- Be sure the Alarm is clean and dust-free.
- Install a fresh 9 volt battery* and test the Alarm again.
WARNING
- DO NOT try fixing the Alarm yourself – this will void your warranty! If the CO Alarm is still not operating properly, and it is stillunder warranty, please see “How to Obtain Warranty Service” inthe Limited Warranty. Install a new CO Alarm immediately.
- The Test/Silence button is the only proper way to test the CO Alarm. NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
*For a list of acceptable replacement batteries, see “Regular Maintenance.”
REGULAR MAINTENANCE
To keep the CO Alarm in good working order:
- Test it every week using the Test/Silence button.
- Vacuum the CO Alarm cover once a month, using the soft brush attachment. Never use water, cleaners, or solvents, since these may damage the unit. Test the CO Alarm again after vacuuming.
- Replace the battery when the CO Alarm “chirps” about every minute (the low battery warning).
The low battery warning should last for 7 days, but you should replace the battery immediately to continue your protection.
Choosing a replacement battery:
This CO Alarm requires one standard 9 volt battery. The following batteries
are acceptable as replacements: Duracell MN1604, Energizer 522, and Ultralife
U9VL-J-P. These replacement batteries are commonly available at local retail
stores.
WARNING
- Always use the exact batteries specified by this User’s Manual. DO NOT use rechargeable batteries. Clean the battery contacts and also those of the device prior to battery installation. Install batteries correctly with regard to polarity (+ and -).
- Please dispose of or recycle used batteries properly, following any local regulations. Consult your local waste management authority or recycling organization to find an electronics recycling facility in your area. DO NOT DISPOSE OF BATTERIES IN FIRE. BATTERIES MAY EXPLODE OR LEAK.
WARNING
- Keep battery out of reach of children. In the event a battery is swallowed, immediately contact your poison control center, your physician, or the National Battery Ingestion hotline at 202-625-3333 as serious injury may occur.
- DO NOT spray cleaning chemicals or insect sprays directly on or near the CO Alarm. DO NOT paint over the CO Alarm. Doing so may cause permanent damage.
IMPORTANT !
Household cleaners, aerosol chemicals, and other contaminants can affect
the sensor. When using any of these materials near the CO Alarm, make sure the
room is well ventilated.
WHAT YOU NEED TO KNOW ABOUT CO WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not
burn completely, or are exposed to heat (usually fire). Electrical appliances
typically do not produce CO.
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline,
kerosene, and propane.
Common appliances are often sources of CO. If they are not properly
maintained, are improperly ventilated, or malfunction, CO levels can rise
quickly. CO is a real danger now that homes are more energy efficient. “Air-
tight” homes with added insulation, sealed windows, and other weatherproofing
can “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed with ALL
household members.
Mild Exposure:
Slight headache, nausea, vomiting, fatigue (“flu-like” symptoms).
Medium Exposure:
Throbbing headache, drowsiness, confusion, fast heart rate.
Extreme Exposure:
Convulsions, unconsciousness, heart and lung failure. Exposure to carbon
monoxide can cause brain damage, death.
WARNING
Some individuals are more sensitive to CO than others, including people with
cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or
elderly people can be more quickly and severely affected by CO. Members of
sensitive populations should
consult their doctors for advice on taking additional precautions.
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it difficult
to locate the source of CO after an alarm. These are a few of the factors that
can make it difficult to locate sources of CO:
- House well ventilated before the investigator arrives.
- Problem caused by “backdrafting.”
- Transient CO problem caused by special circumstances.
Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.
HOW CAN I PROTECT MY FAMILY?
A CO Alarm is an excellent means of protection. It monitors the air and sounds
a loud alarm before carbon monoxide levels become threateningfor average,
healthy adults. A CO Alarm is not a substitute for proper maintenance of home
appliances.
To help prevent CO problems and reduce the risk of CO poisoning:
-
Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper air flow. Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent proper air movement and cause backdrafting. Never “cap” or cover a chimney in any way that would block air flow.
-
Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee.
-
Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and scaling. Also check the flame on the burner and pilot lights. The flame should be blue. A yellow flame means fuel is not being burned completely and CO may be present.
Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not grill or barbecue indoors, or in garages or on screen porches. -
Check for exhaust backflow from CO sources. Check the draft hood on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.
-
Check the house or garage on the other side of shared wall.
-
Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a window or a door. Opening windows and doors can significantly decrease CO levels. In addition, familiarize yourself with all enclosed materials. Read this manual in its entirety, and make sure you understand what to do if your CO Alarm sounds.
Fuel-burning appliances like: portable heater, gas or wood burning fireplace,
gas kitchen range or cooktop, gas clothes dryer.
Damaged or insufficient venting: corroded or disconnected water heater vent
pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or
clogged chimney opening.
Improper use of appliance/device: operating a barbecue grill or vehicle in an
enclosed area (like a garage or screened porch).
Transient CO Problems: “transient” or on-again-off-again CO problems can be
caused by outdoor conditions and other special circumstances.
POTENTIAL SOURCES OF CO IN THE HOME
The following conditions can result in transient CO situations:
-
Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
• Wind direction and/or velocity, including high, gusty winds.
Heavy air in the vent pipes (cold/humid air with extended periods between cycles).
• Negative pressure differential resulting from the use of exhaust fans.
• Several appliances running at the same time competing for limited fresh air.
• Vent pipe connections vibrating loose from clothes dryers, furnaces, or water heaters.
• Obstructions in or unconventional vent pipe designs which can amplify the above situations. -
Extended operation of unvented fuel burning devices (range, oven, fireplace).
-
Temperature inversions, which can trap exhaust close to the ground.
-
Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.
REGULATORY INFORMATION FOR CO ALARMS
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms
to sound when exposed to levels of CO and exposure times as described below.
They are measured in parts per million (ppm) of CO over time (in minutes).
UL2034 Required Alarm Points*:
-
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES.
-
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
-
If the alarm is exposed to 70 ppm of CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.
-
Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH). The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.
IMPORTANT !
- An exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.
- An exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours.
IMPORTANT !
This CO Alarm measures exposure to CO over time. It alarms if CO levels are
extremely high in a short period of time, or if CO levels reach a certain
minimum over a long period of time. The CO Alarm generally sounds an alarm
before the onset of symptoms in average, healthy adults.
Why is this important? Because you need to be warned of a potential CO problem
while you can still react in time. In many reported cases of CO exposure,
victims may be aware that they are not feeling well, but become disoriented
and can no longer react well enough to exit the building or get help. Also,
young children and pets may be the first affected. The average healthy adult
might not feel any symptoms when the CO Alarm sounds. However, people with
cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or
elderly people can be more quickly and severely affected by CO. If you
experience even mild symptoms of CO poisoning, consult your doctor
immediately! Standards: Underwriters Laboratories Inc. Single and Multiple
Station
carbon monoxide alarms UL2034.
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon
monoxide alarms covered by these requirements are intended to respond to the
presence of carbon monoxide from sources such as, but not limited to, exhaust
from internal- combustion engines, abnormal operation of fuel-fired
appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide
levels below those that could cause a loss of ability to react to the dangers
of Carbon Monoxide exposure.” This CO Alarm monitors the air at the Alarm, and
is designed to alarm before CO levels become life threatening. This allows you
precious time to leave the house and correct the problem. This is only
possible if Alarms are located, installed, and maintained as described in this
manual. Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm
is not formulated to detect CO levels below 30 ppm typically. UL tested for
false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500
ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide
(5000 ppm). Values measure gas and vapor concentrations in parts per million.
Audible Alarm: 85 dB minimum at 10 feet (3 meters).
GENERAL LIMITATIONS OF CO ALARMS
This CO Alarm is intended for residential use. It is not intended for use in
industrial applications where Occupational Safety and Health Administration
(OSHA) requirements for carbon monoxide detectors must be met.
CO alarms may not waken all individuals. If children or others do not readily
waken to the sound of the CO alarm, or if there are infants or family members
with mobility limitations, make sure that someone is assigned to assist them
in the event of an mergency.
CO Alarms will not work without power. This alarm requires one standard 9 volt
battery to operate.
CO Alarms for Solar or Wind Energy users and battery backup power systems: AC
powered CO Alarms should only be operated with true or pure sine wave
inverters. Operating this Alarm with most battery-powered UPS (uninterruptible
power supply) products or square wave or “quasi sine wave” inverters will
damage the Alarm. If you are not sure about your inverter or UPS type, please
consult with the manufacturer to verify.
This CO Alarm will not sense carbon monoxide that does not reach the sensor.
This CO Alarm will only sense CO at the sensor. CO may be present in other
areas. Doors or other obstructions may affect the rate at which CO reaches the
CO Alarm. For this reason, if bedroom doors are usually closed at night, we
recommend you install a CO Alarm in each bedroom and in the hallway between
them. CO Alarms may not sense CO on another level of the home. For example, a
CO Alarm on the second level, near the bedrooms, may not sense CO in the
basement. For this reason, one CO Alarm may not give adequate warning.
Complete coverage is recommended. Place CO Alarms on each level of the home.
CO Alarms may not be heard. The alarm horn loudness meets or exceeds current
UL standards of 85 dB at 10 feet (3 meters). However, if the CO Alarm is
installed outside the bedroom, it may not wake up a sound sleeper or one who
has recently used drugs or has been drinking alcoholic beverages. This is
especially true if the door is closed or only partly open. Even persons who
are awake may not hear the alarm horn if the sound is blocked by distance or
closed doors. Noise from traffic, stereo, radio, television, air conditioner,
or other appliances may also prevent alert persons from hearing the alarm
horn. This CO Alarm is not intended for people who are hearing impaired. CO
Alarms are not a substitute for a smoke alarm. Although fire is a source of
carbon monoxide, this CO Alarm does not sense smoke or fire. This CO Alarm
senses CO that may be escaping unnoticed from malfunctioning furnaces,
appliances, or other sources. Early warning of fire requires the installation
of smoke alarms. CO Alarms are not a substitute for life insurance. Though
these CO Alarms warn against increasing CO levels, BRK Brands, Inc. does not
warrant or imply in any way that they will protect lives from CO poisoning.
Homeowners and renters must still insure their lives. CO Alarms have a limited
life. Although the CO Alarm and all of its parts have passed many stringent
tests and are designed to be as reliable as possible, any of these parts could
fail at any time. Therefore, you must test your CO Alarm weekly. CO Alarms are
not foolproof. Like all other electronic devices, CO Alarms have limitations.
They can only detect CO that reaches their sensors. They may not give early
warning to rising CO levels if the CO is coming from a remote part of the
home, away from the CO Alarm.
TROUBLESHOOTING GUIDE
PROBLEM… | THIS MEANS… | YOU SHOULD… |
---|
The light continues to flash (RED) and the horn
“chirps” once every minute.| Low battery warning.| Install 1 new 9 volt
battery*.
The light flashes (RED) and the horn sounds 3 “chirps” every minute.|
MALFUNCTION SIGNAL. CO Alarm needs to be replaced.| CO Alarms under warranty
should be returned to manufacturer for replacement. See “Limited Warranty” for
details.
The light flashes (RED) and the horn sounds 5 “chirps” every minute.| END OF
LIFE SIGNAL. CO Alarm needs to be replaced.| Immediately replace the CO Alarm.
CO Alarm goes back into alarm 4 minutes after you press the Test/Silence
button.| CO levels indicate a potentially dangerous situation.| IF YOU ARE
FEELING SYMPTOMS OF CO POISONING, EVACUATE your home and call 911 or the Fire
Department. If not, press the Test/Silence button again and keep ventilating
your home.
CO Alarm sounds frequently even though no high levels of CO are revealed in an
investigation.| The CO Alarm may be improperly located. Refer to “Where to
Install CO Alarms.”| Relocate your alarm. If frequent alarms continue, have
home rechecked for potential CO problems. You may be experiencing an
intermittent CO problem.
*For a list of acceptable replacement batteries, see “Page 4: Regular Maintenance.”
If you have any questions that cannot be answered by reading this manual, call
Consumer Affairs at 1-800-323-9005.
LIMITED WARRANTY
BRK Brands, Inc. (“BRK”) the maker of BRK brand and First Alert brand
products, warrants that for a period of seven years from the date of purchase,
this product will be free from defects in material and workmanship. BRK, at
its option, will repair or replace this product or any component of the
product found to be defective during the warranty period. Replacement will be
made with a new or remanufactured product or component. If the product is no
longer available, replacement may be made with a similar product of equal or
greater value. This is your exclusive warranty. This warranty is valid for the
original retail purchaser from the date of initial retail purchase and is not
transferable. Keep the original sales receipt. Proof of purchase is required
to obtain warranty performance. BRK dealers, service centers, or retail stores
selling BRK products do not have the right to alter, modify or any way change
the terms and conditions of this warranty. This warranty does not cover normal
wear of parts or damage resulting from any of the following: negligent use or
misuse of the product, use on improper voltage or current, use contrary to the
operating instructions, disassembly, repair or alteration by anyone other than
BRK or an authorized service center. Further, the warranty does not cover acts
of God, such as fire, flood, hurricanes and tornadoes or any batteries that
are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by
the breach of any express or implied warranty. Except to the extent prohibited
by applicable law, any implied warranty of merchantability or fitness for a
particular purpose is limited in duration to the duration of the above
warranty. Some states, provinces, or jurisdictions do not allow the exclusion
or limitation of incidental or consequential damages or limitations on how
long an implied warranty lasts, so the above limitations or exclusion may not
apply to you. This warranty gives you specific legal rights, and you may also
have other rights that vary from state to state, or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer.
In order to obtain warranty service, contact the Consumer Affairs Division at
1-800-323-9005, 7:00 AM – 7:00 PM
Central Standard Time, Monday through Friday and 8:00 AM – 6:00 PM Central
Standard Time, Saturday and Sunday. To assist in serving you, please have the
model number and date of purchase available when calling.
For Warranty Service return to: 1301 Joe Battle, El Paso, TX 79936 Battery:
BRK Brands, Inc. makes no warranty, express or implied, written or oral,
including that of merchantability or fitness for any particular purpose, with
respect to battery.
For more information and updates, please visit
www.firstalert.com
For your records, please record:
Date Purchased: ____Where Purchased:
Date Installed: ____/____Month/Year
Replace alarm 5 years after installation. Please write the date in the space
provided: /____Month/Year
The alarm will also provide an audible End-of-Life Signal approximately 7
years after installation to remind you to replace the unit.
The End-of-Life Signal can be silenced for up to 2 days.
Do not unplug the alarm or remove the batteries until you get replacement.