RONDS RW506 Wireless Vibration Temperature Sensor User Manual
- June 12, 2024
- RONDS
Table of Contents
- RW506 Wireless Vibration Temperature Sensor
- Overview
- Working Principle and Structural Features
- Dimensions, Weight and Material
- Installation and Operation Notices
- Installation and Use
- Repair and Maintenance
- Common Fault Treatment
- Transportation and Storage
- Unpacking and Inspection
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Wireless Vibration
Temperature Sensor
Manual
Executive standard:
GB/T 3836.1-2021
GB/T 3836.4-2021
Q/RH081—2022
Version number: VER 1.1
Publication date: 2022.6
RW506 Wireless Vibration Temperature Sensor
Please read carefully before using the Manual
Anhui Ronds Science & Technology Incorporated Company
Preface
This manual describes the use method and precautions of the wireless Vibration
Temperature sensor. Users must read it carefully before use. The wireless
Vibration Temperature sensor implements the enterprise standard Q/RH081-2022
of Anhui Ronds Science & Technology Incorporated Company.
Warning:
- Read the operation manual before installation and use, and install and operate in strict accordance with the methods in the manual.
- Do not modify the circuit without authorization.
- The model, specification and electrical parameters of related short circuits and components shall not be modified during maintenance.
- It is forbidden to replace batteries in explosion-proof places, and batteries other than those specified in the specifications shall not be replaced.
- The product shell contains plastic material, which has the potential danger of electrostatic charge! Avoid friction during use! Please wipe with a damp cloth when cleaning.
Overview
1.1 Uses and Application Scope
The wireless Vibration Temperature sensor (hereinafter referred to as the
sensor) can monitor the equipment vibration signal, and can monitor the
vibration data for a long time and transmit it.
The sensor has intrinsically safe explosion-proof function and meets the
standards of GB/T 3836.1-2021 Explosive Atmospheres Part 1: Equipment–General
Requirements and GB/T 3836.4-2021 Explosive Atmospheres Part 4: Equipment
Protected by Intrinsically safe “i”; The explosion-proof sign is Ex ia ⅡC T4
Ga, which can be installed in normal places and dangerous places in Zone 0
with ⅡA, ⅡB, ⅡC dangerous gases. The sensor communicates wirelessly.
1.2 Functional Features
- Wireless transmission. saves a lot of wiring work such as signal, power supply and network
- Adopt transmission frequency of 2.4G free frequency band, with long transmission distance and strong anti-interference ability, which is convenient for industrial field use
- Low power design. Able to monitor and transmit vibration data for a long time.
- Small size. Suitable for installation in various industrial sites.
- Support temperature measurement.
1.3 Model description
The current product models are as follows:
RW506:
Frequency response range: Z-axis direction 2-20000Hz (±3dB ); Analysis
frequency: Z axis 1000Hz,10000Hz ,20000Hz; Battery life: 5 years (estimated
under the condition that the temperature is 25 ℃
(± 2 ℃) and the conventional index is 30 minutes / time, the service life
decreases under the conditions of extreme low temperature and extreme high
temperature); Temperature measurement range: -40℃~125℃; RW506M:
RW506M has the same performance parameters as RW506W, and RW506M has working
condition monitoring function.
RW606: Frequency response range: Z-axis direction 0.1-20000Hz (±3dB ), X &
Y-axis direction 0.1-1000Hz (±3dB );Analysis frequency: Z axis 1000Hz,
10000Hz, 20000Hz; X & Y-axis direction 1000Hz;
Battery life: 5 years (estimated under the condition that the temperature is
25 ℃ (± 2 ℃) and the conventional index is 30 minutes / time, the service life
decreases under the conditions of extreme low temperature and extreme high
temperature); Temperature measurement range: -40℃~125℃; RW606M: RW606M has the
same performance parameters as RW606, and RW606M has working condition
monitoring function.
1.4 Application Environment Conditions
1.4.1 Working Environment Conditions
a) Ambient temperature: -40℃~+70℃;
b) Average relative humidity: ≤95%HR (+25℃ );
c) Atmospheric pressure: 70kPa~110kPa;
d) Occasions without ponding;
e) Zone 0 hazardous places with IIA, IIb and IIC hazardous gases, but without
corrosive gases damaging insulation.
1.4.2 Bearable Storage and Transportation Conditions
a) High temperature: +85℃;
b) Low temperature: -40℃;
c) Average relative humidity: +95%HR (+25℃ );
d) Vibration: 50m/s2;
e) Impulse: 500m/s2。
1.5 Safety Features
Explosion proof type: intrinsically safe, explosion-proof sign: Ex ia IIC T4
Ga
Working Principle and Structural Features
2.1 Operating Voltage and Current
a) Operating voltage: rated voltage 3.6V (battery is one of the following
three models)
- VE ER34615 Maximum open circuit voltage 3.9V;
- LISUN ER34615 Maximum open circuit voltage 3.9V;
b) Operating current of the whole machine: ≤50mA;
2.2 Measurement Range
vibration acceleration (Z-axis direction) measurement range: ±50g;
(g:gravitational acceleration g=9.8m/s2)
vibration acceleration (X & Y-axis direction) measurement range: ±16g
(g:gravitational acceleration g=9.8m/s2)
Resolution ratio is 0.01m/s2; Temperature measurement range: -40℃~125℃
2.3 Basic Error
Allowable basic error of vibration measurement:±3dB; 2.4 Linearity Linearity:
2%;2.5 Signal Output Way
2.4G (IEEE 802.15.4 )Wireless communication:
- Frequency: 2405MHz~2475MHz
- Transmission distance: 300 meters line of sight.
BLE Wireless communication:
- Frequency: 2402MHz~2480MHz
- Transmission distance: 50 meters line of sight.
2.6 IP Grade:IP68 (1m, 40min)
Dimensions, Weight and Material
*3.1 Dimensions: φ45.5110.3mm (diameter×Height, including mounting base
);
3.2 Weight: About 320g (including mounting base);
3.3 Upper cover material: flame retardant PC;**
Battery compartment material: flame retardant PA66 + 30% glass fiber + SUS304
(integrated injection molding);
Base and mounting base material: SUS316 stainless steel.
Installation and Operation Notices
- Please read the operation manual carefully before using this product.
- This product should be used and maintained by trained personnel or special personnel.
- Avoid knocking, falling, being close to high temperature source for a long time and being used in high corrosion environment for a long time.
- Install the sensor correctly to ensure the sensitivity of the sensor and the accuracy of the measured data.
- It is not allowed to replace the original device or structure to avoid affecting the explosion-proof performance.
- Only use the following brands of specified models of batteries: EVE ER34615, 3.6V 19Ah Lithium Thionyl Chloride (LiSOCI2)
②LISUN ER34615, 3.6V 19Ah Lithium Thionyl Chloride (LiSOCI2)
(7)The upper cover of the product and the shell of the battery compartment are made of flame retardant PA66 + 30% glass fiber + SUS304 (integrated injection molding), which has potential electrostatic hazards. Avoid friction during use! Please wipe with a damp cloth when cleaning.
Installation and Use
5.1 Production Date and Certificate Validity
a) Production date: see “product delivery inspection report” for details;
b) Certificate validity: see “explosion proof certificate” for details.
5.2 Installation Methods
Magnetic base + gluing, adapter base + screw hole, adapter base + welding
Note: If the vibration amplitude of equipment is large, it is recommended to
adopt the installation method of adapter + screw hole or adapter + welding.
5.3 Use Methods
a) Configure by using the supporting dongle.
b) Set the same wireless band with matched gateway.
c) When replacing the battery, it must be carried out in strict accordance
with the relevant requirements of “repair and maintenance” in Article 4.
Repair and Maintenance
6.1 Repair
- Please read the manual carefully before use and follow the operating steps.
- Do not change any parameters of the sensor circuit.
- Only use the battery model described in Article 4.
- Battery replacement shall be carried out in a safe place.
6.2 Maintenance
6.2.1 A designated person must be responsible for the daily maintenance of
the sensor.
6.2.2 Maintenance personnel must carefully read and be familiar with
Wireless
Vibration Temperature Sensor Manual and relevant circuit diagrams, and be
familiar
with the internal and external structure and circuit principle of the sensor.
6.2.3 The maintenance personnel should always check whether the sealing part
of the sensor is compressed and whether the cover plate screws are fastened.
Common Fault Treatment
- If the data cannot be uploaded, first check whether the battery is powered. If not, please replace the battery.
- If the data is not uploaded in time, first check the wireless signal quality at the installation position to ensure that there is no shielding equipment around.
Transportation and Storage
8.1 Avoid violent vibration and impact when transporting and handling the
sensor.
8.2 Strictly prohibited to put the sensor in the place directly dripping
with water when store it.
Unpacking and Inspection
9.1 Pay attention to safety when unpacking to avoid damage to equipment
or injury.
9.2 After unpacking, check whether the appearance of the equipment is
damaged and whether the accessories are complete.
9.3 Accessories list
a) Instruction Manual 1 pcs
b) Sensor 1 pcs
c) Product certificate 1 pcs
d) Packing list 1 pcs
Manufacturer: Anhui Ronds Science & Technology Incorporated Company
Address: #59, Branch Road of Biomedical park, High-tech district, Hefei,
Anhui, China
FCC Statement
FCC ID:2AKW5-RW506
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body
Read User Manual Online (PDF format)