RONDS RH570 Wireless Data Collector User Manual

June 12, 2024
RONDS

RH570 Wireless Data Collector
User Manual
Please read the user manual before using the product
RH570 Wireless Data Collector
User Manual

Attention:

  • Before installation and use, read the operating instructions, and install and operate in strict accordance with the methods in the instructions
  • Do not modify the circuit without authorization
  • The model, specification and electrical parameters of associated short circuit and components shall not be modified during maintenance
  • It is forbidden to install antennas in explosion-proof places

Product Introduction

1.1 Features

RH570 wireless data collector is a new generation wireless product of the company, which has rich wireless data transmission functions. It can be applied to a variety of application scenarios by configuring different modules, and has wired data transmission functions. With different wireless sensors and monitoring sensors of our company as the monitoring system, it integrates continuous acquisition, calculation, storage and transmission, and can be flexibly adapted to equipment status monitoring in various occasions such as petrochemical, steel, cement, coal, etc.
Based on the access monitoring requirements of different on-site wireless sensors and different live trigger modes, RH570 can be designed to meet different on-site equipment monitoring needs and achieve accurate, and real- time monitoring. RH570 supports both power supply and battery-powered, enabling all-wireless deployment.
It has the following main characteristics:

  • It has network interface, 4G, WIFI, Zigbee, LoRa and other communication modes to provide options, which can meet the needs of various network environments on site;
  • It can be used in combination with Ronds single-axis vibration, three-axis vibration and other types of wireless sensors to meet the monitoring mode requirements of different measuring points;
  • The machine learning classification algorithm can be used to effectively divide the startup and shutdown status of various types of equipment to achieve fully automatic equipment startup and shutdown status recognition;
  • With edge intelligent alarm, rich alarm indicator system, adaptive threshold calculation, and hierarchical alarm output according to fault severity;
  • The alarm data can be uploaded in time according to the severity of the equipment failure to meet the requirements of rapid deterioration equipment care;
  • With data timing alignment upload, improve the requirements of intelligent diagnosis and care, and avoid timing deviation and other problems of data at different acquisition locations。

1.2 Product model

Product name: Wireless Data Collector
Product model: RH570
Function description: RH570 is the product model of this series of data collector, with the following communication modes:
Uplink communication mode: 4G, WIFI and network interface communication;
Downlink communication is Zigbee and LoRa communication, with industrial interface RS485 and CAN communication.
1.3 Technical parameter table

Power supply

Power supply| AC100V-AC240V(50/60Hz)|
Basic parameters
CPU1 main frequency| 1.0GHz single core| Standard configuration
CPU1 storage| Internal storage: RAM: 128MB DDR2
External storage: standard configuration
EMMC: 8~128GB optional| Standard configuration
CPU2 main frequency| 96-192MHz single core| Standard configuration
CPU2 storage| Internal storage:
RAM: 928KB RAM
External storage:
PSRAM: 64Mbit/128Mbit
EMMC: 8~128GB optional| Standard configuration
Key performance
Industrial communication interface| RS485:1 channel CAN: 1channel| Optional
Communication mode with server| WIFI:2.4G| Optional
2.4G WiFi and 4G cannot be transmitted at the same time
All-network communication 4G:
LTE-FDD/LTE-TDD/LTE-TDD1.8G, APN configurable
RJ45 network interface:10/100Base-TX|
Communication mode with sensor| Zigbee: 2.4GHz IEEE 802.15.4
Lora: 915MHz(optional)|
Communication distance with sensor| Zigbee: 300m line of sight
Lora: 1.5Km line of sight|
Maximum number of supported sensors| Zigbee: 60pcs
LoRa: 255pcs|
Edge computing| Support|
Product upgrade method
Handheld Debugger Upgrade| Support the upgrade of Rounds debugger|
PC upgrade| Upgrade via USB to zigbee|
Remote firmware upgrade| Remote upgrade via upper computer|
Structural parameters
Dimensions| 260mm203mm87mm| long × wide × high
Weight| 2.5kg|
IP Grade| IP66|
Shell material| Cast aluminium|
Environmental parameters
Ambient environment| -40℃~70℃,≤95%RH,non-condensing|
Storage environment| -50~85℃,≤95%RH,non-condensing|
Atmospheric pressure| 70kPa ~110kPa|
Reliability parameters
ESD immunity| EN61000-4-2
Test level: 4
Test voltage:
±8kV (Contact discharge)
±15kV (Air discharge)|
Power  frequency withstand voltage level| 500VAC|
Insulation resistance| Metal grounding of main body shell, insulation resistance of non-metal antenna shell>1GΩ|

1.4 Performance description
1.4.1 Power performance
Wireless intelligent data collector power supply voltage : AC100V- AC240V/(50/60Hz).
1.4.2 Wire communication
The data collector has a variety of wired communication modes, including Ethernet, RS485 and CAN.
1.4.3 Wireless communication
The data collector has a variety of wireless communication modes, including ZigBee, LoRa, WIFI, 4G, and the corresponding antenna is used as needed.
1.5 Wireless parameters
1.5.1 WiFi
a) Operating frequency:2400MHz~2485MHz
b) Modulation mode: IEEE 802.11b/g/n
c) Output power:≤28.5dBm (Including antenna gain 11dBi);
1.5.2 ZigBee
a) Number of channels: 2 channels (receiving)
b) Operating frequency: 2405MHz~2485MHz
c) Modulation mode: IEEE 802.15.4
d) Output power: ≤11dBm(Including antenna gain 5dBi);
1.5.3 ZigBee
a) Number of channels: 1 channel (sending)
b) Operating frequency: 2405MHz~2485MHz
c) Modulation mode: IEEE 802.15.4
d) Output power: ≤24dBm(Including antenna gain 5dBi);
1.5.4 LORA
a) Operating frequency:915MHz
b) Modulation mode: LoRa modulation mode is supported
c) Output power: ≤20dBm(Including antenna gain 6dBi);
1.5.5 4G
a) Operating frequency:
LTE-TDD: B1/B3/B7/B8/B20/B28
LTE-TDD: B38/B40
b) Modulation mode: LTE TDD、LTE FDD
c) Output power: ≤30dBm(Including antenna gain 5dBi);
1.6, RF antenna

Antenna type Model Gain Manufacture
Zigbee antenna TQJ-2400D 5dBi Kenbotong Technology Co.,Ltd.
Lora antenna TQJ-900AT6 6dBi Kenbotong Technology Co.,Ltd.
Wifi antenna TDJ-2400BKC90-VB1 11dBi Kenbotong Technology Co.,Ltd.
4G antenna AMXF-8027-5 3/5dBi Aimeixun Co.,Ltd.

Chapter II Usage Introduction

2.1 installation

  1. Product lead-in device: the installation position of gland is shown in the figure below, and the number of gland: 2; Model: SH-BDM-1.RONDS RH570 Wireless Data Collector -
  2. Set the switch on the power board to “OFF” before installation;
  3. The allowable power line diameter of the gland is Ø 5.5~Ø 12mm. It is introduced from the gland marked with “PWR” at the bottom. It is connected to the terminal according to the live line, zero line and ground line marked on the power interface on the power board, and locked with a screwdriver. The installation torque is 0.1 ± 0.02N. m; Then use the tool to lock the gland, and the installation torque is 0.6 ± 0.05N. m;
  4. The network cable is introduced from the gland marked with “NET”, and then the crystal base is crimped, connected to the corresponding communication module interface, and the gland is locked at the same time. The installation torque is 0.6 ± 0.05N. m.
  5. Antenna: the top of the shell is marked with the position screen of each antenna. Install the antenna according to the identification and tighten it with tools. The installation torque is 0.6 ± 0.05N. m to ensure that it will not be unscrewed by hand. The bottom 4G/WIFI antenna is connected through the RF feed line. The antenna is installed vertically upwards. The RF feed line model is RG213/U (4G&WIFI), and the installation torque is 0.6 ± 0.05N. m. The following figure shows the installation direction of acquisition station and antenna: RONDS RH570 Wireless Data Collector - diagramRONDS RH570 Wireless Data Collector - Wifi antenna
  6. Connect the external grounding, the cross sectional area of the grounding wire shall not be less than 4mm2, and the grounding wire shall be installed on the bolt marked with the grounding mark at the bottom of the shell, with the installation torque of 0.6 ± 0.05N. m.
  7. After installation, put the main board switch in the “ON” state. After powering on, check the housing indicator. The indicator light RUN lights up to indicate that it is powered on, and the COM flashes to indicate that the communication is normal.

Attention:
The interface between 4G antenna and WIFI antenna is a standard N-type connector, which needs to be installed by professionals. Consumers should not install it by themselves.
2.2 Precautions for operation

  1. Before installing the instrument, please ensure that you can provide a suitable working environment and sufficient physical space. After the instrument is in place, it is fixed by hanging lugs and screws. The installation method is vertical installation.
  2. The antenna shell of the product is made of plastic material, which has potential electrostatic charge hazard. Avoid friction. Please wipe it with wet cloth when cleaning. It is forbidden to install the antenna in explosion-proof places.
  3. This instrument needs to be used and maintained by personnel trained for a certain time or special personnel.
  4. The use of the instrument should be avoided as far as possible: knocking, falling, long time close to high temperature source and long time use in high corrosive environment, so as not to affect the performance of the instrument.
  5. During the use and maintenance of this product, the model, specification and parameters of the structure and components related to the explosion-proof performance shall not be changed. The transformation of explosion-proof products can only be carried out by the product manufacturer and can only be used after passing the inspection by a qualified inspection agency.
  6. The user of the product shall not change the associated equipment and matching equipment of the explosion-proof product at will, otherwise the explosion-proof performance of the product will be changed, resulting in the loss of explosion of the product.
  7. The shell of the intrinsically safe wireless monitoring station is made of aluminum alloy. During installation and use, the ignition hazard caused by impact or friction shall be prevented.
  8. During product installation, the shell must be reliably grounded, and the grounding wire shall not be less than 4mm²

2.3 Repair

  1. Please read the manual carefully before use and follow the operating steps.
  2. Do not change any parameters of the data collector circuit.
  3. Battery replacement shall be carried out in a safe place.

2.4 Maintenance

  1. A designated person must be responsible for the daily maintenance of the sensor.
  2. Maintenance personnel must carefully read and be familiar with Wireless Data Collector User Manual and relevant circuit diagrams, and be familiar with the internal and external structure and circuit principle of the sensor.
  3. During use, maintenance and service personnel should always check whether the sealing part of the data collector is tight and whether the screws are tight.

2.5 Transportation and Storage

  1. Avoid violent vibration and impact when transporting and handling the data collector.
  2. Strictly prohibited to put the data collector in the place directly dripping with water when store it.

2.6 Unpacking and Inspection

  1. Pay attention to safety when unpacking to avoid damage to equipment or injury.
  2. After unpacking, check whether the appearance of the equipment is damaged and whether the accessories are complete.
  3. Accessories list
    a) Instruction Manual| 1 pcs
    ---|---
    b) Data collector| 1 pcs
    c) Product certificate| 1 pcs
    d) Packing list| 1 pcs

Manufacturer: Anhui Ronds Science & Technology Incorporated Company
Address: #59 Branch Road of Biomedical park, High-tech district, Hefei, Anhui, China
Postcode: 230000
Telephone: 4008551298

FCC Statement

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help important announcement

Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Version number: VER 1.0
Date of publication: 2023.04

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

RONDS User Manuals

Related Manuals