EHEIM reeflexUV+e 500 Microorganisms Instruction Manual

June 12, 2024
EHEIM

EHEIM reeflexUV+e 500 Microorganisms Instruction Manual

EHEIM reeflexUV+e 500 Microorganisms Instruction
Manual![EHEIM reeflexUV+e 500 Microorganisms

Hereby, EHEIM GmbH & Co. KG, declares that the radio equipment type EHEIM reeflexUV+e is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.eheim.com

EHEIM reeflexUV+e 500 Microorganisms - Overview EHEIM reeflexUV+e 500 Microorganisms - Fig A EHEIM
reeflexUV+e 500 Microorganisms - Fig B

IMPORTANT SAFETY INSTRUCTIONS

WARNING ­- To guard against injury, basic safety precautions should be observed, including the following.

  • a) READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

  • b ) DANGER ­ To avoid possible electric shock, special care should be taken since water is employed in the use of aquarium equipment. For each of the following situations, do not attempt repairs by yourself; return the appliance to an authorized service facility for service or discard the appliance.

    1. If the appliance falls into the water, DON’T reach for it! First unplug it and then retrieve it. If electrical components of the appliance get wet, unplug the appliance immediately. (Non-immersible equipment only)
    2. If the appliance shows any sign of abnormal water leakage, immediately unplug it from the power source. (Immersible equipment only)
    3. Carefully examine the appliance after installation. It should not be plugged in if there is water on parts not intended to be wet.
    4. Do not operate any appliance if it has a damaged cord or plug, or if it is malfunctioning or has been dropped or damaged in any manner.
    5. To avoid the possibility of the appliance plug or receptacle getting wet, position aquarium stand and tank to one side of a wall-mounted receptacle to prevent water from dripping onto the receptacle or plug.
      A “drip loop”, shown in the figure, should be arranged by the user for each cord connecting an aquarium appliance to a receptacle. The “drip loop” is that part of the cord below the level of the receptacle, or the connector if an extension cord is used, to prevent water traveling along the cord and coming in contact with the receptacle.
      If the plug or socket does get wet, DON’T unplug the cord. Disconnect the fuse or circuit breaker that supplies power to the appliance. Then unplug and examine for presence of water in the receptacle.
  • c) Close supervision is necessary when any appliance is used by or near children.

  • d) To avoid injury, do not contact moving parts or hot parts such as heaters, reflectors, lamp bulbs, and the like.

  • e) Always unplug an appliance from an outlet when not in use, before putting on or taking off parts, and before cleaning. Never yank cord to pull plug from outlet. Grasp the plug and pull to disconnect.

  • f ) Do not use an appliance for other than intended use. The use of attachments not DRIP recommended or sold by the appliance manufacturer may cause an unsafe condi- LOOP tion.

  • g) Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing.

  • h) Make sure an appliance mounted on a tank is securely installed before operating it.

  • i) Read and observe all the important notices on the appliance.

  • j) If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less amperes or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.

  • k) This appliance has a polarized plug (one blade is wider than the other). As a safety feature, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use with an extension cord unless plug can be fully inserted. Do not attempt to defeat this safety feature.

  • l) “SAVE THESE INSTRUCTIONS”.

FCC WARNING STATEMENT (USA only)

FCC CAUTION

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

GROUNDING INSTRUCTIONS

EHEIM reeflexUV+e 500 Microorganisms - GROUNDING
INSTRUCTIONS

This appliance should be grounded to minimize the possibility of electric shock. This appliance is equipped with an electric cord having an equipment grounding conductor and a grounding type plug. The plug must be plugged into an outlet that is installed and grounded in accordance with all appropriate codes and ordinances.

This appliance is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in (A) below. A temporary adapter which looks like the adapter illustrated in (B) and (C) below may be used to connect this plug to a two-pole receptacle as shown in (B) if a grounded outlet is not available. The temporary adapter should be used only until a grounded outlet can be installed by a qualified electrician. The green-colored rigid ear (lug, and the like) extending from the adapter must be fastened to a permanent ground such as a grounded outlet box.

The EHEIM reeflexUV+e clarifiers use UV-C radiation to disinfect aquarium water in fresh and sea water aquariums and are operated in the filter system’s water cycle (discharge side) or by using a separate circulation pump (not included).

Aquarium water permanently flows through a glass tube and past the UV-C bulb inside the aluminium body. As a result, free-floating algae, bacteria, fungi, viruses and other pathogens are reduced or eliminated. The EHEIM reeflexUV+e clarifiers ensure that aquarium water is clean and crystal-clear, keeping the fish healthy.

UVC clarifier reeflexUV+e 500 / 800 / 1500 / 2000

General user instructions

Information on using the operating manual

Before using the appliance for the first time, the operating manual must be read fully and understood. Carefully read the user instructions before opening the device for servicing.

Consider the operating manual as part of the product and keep in a safe and accessible location.

Enclose this operating manual if passing the appliance on to a third party.

Symbol explanation

The following symbols are used on the appliance:

EHEIM reeflexUV+e 500 Microorganisms - Symbol
explanation

Application

The appliance and all parts included in the scope of delivery are intended for private use and must only be used: · For the disinfection of aquarium water in fresh and salt water aquariums · indoors · in compliance with the technical data

The UV lamp in this system conforms to the applicable provisions of the Federal Regulations (CFR) requirements including, Title 21, Chapter 1, Subchapter J, Radiological Health.

The following limitations apply to the appliance:

  • Never operate the UVC lamp outside the housing or use it for other purposes.
  • do not use for commercial or industrial purposes
  • the water temperature may not exceed 35°C
  • Corrosive, flammable aggressive or explosive substances, food and drinking water must not be conveyed.
  • never operate without a water flow

Safety instructions

Risks for persons and property can arise from this appliance if the appliance is improperly used or not used as intended or if the safety instructions are not heeded.

For your safety

  • Do not let the appliance packaging and small parts get into the hands of children or people who are unaware of how to handle them, as hazards can arise (danger of suffocation!). Keep away from animals.

  • Only for EU countries:
    This appliance can be used by children from the age of 8 and by persons with reduced physical, sensory or mental capabilities or lack of experience and/or knowledge if they are supervised and have been instructed in the safe use of the appliance and have understood the resulting dangers. Children must not play with the appliance. Cleaning and user maintenance must not be carried out by children unless they are supervised.

  • This equipment is not intended for use by persons (including children) with limited physical, sensory or mental abilities or for persons with no experience or knowledge unless they are supervised by a person respond for safety or unless they have received from such a person instructions on how to use the equipment. Children should be supervised to ensure that they do not play with the equipment.

  • Before use, carry out a visual inspection to ensure that the appliance, especially the mains cable and plug, are undamaged.

  • Do not use the device if it does not function properly or if it is damaged.

  • Never use the appliance with a damaged mains cable.

  • Repairs must only be carried out by an EHEIM service centre.

  • Do not carry the appliance by the mains cable, and to disconnect from the mains, always pull on the plug and not on the cable or appliance.

  • Only carry out the work described in these instructions.

  • Never make technical modifications to the appliance.

  • Only use original spare parts and accessories for the appliance.

  • Never use the UVC lamp outside the housing.

  • Never look into the light of the UVC lamp.

  • The electrical installation must be in accordance with the international and national constructors’ regulations.

  • To protect against contact voltage being too high, the fixture should have a residual current device with a rated release fault current not exceeding 30 mA. Ask your electrician.

  • In the event of water leakage or when the residual current protection device is triggered, immediately disconnect all devices in the aquarium from the power supply.

  • If they are not being used, always disconnect all devices in the aquarium from the power supply before you install/remove any parts and before all cleaning and maintenance work.

  • The mains connection cable of the pump cannot be replaced. If the cable is damaged, the pump must be scrapped.

  • Protect the mains socket and mains plug against moisture. It is recommended to form a drip loop with the mains cable to prevent any water running along the cable to the mains socket.

  • The electrical data of the pump must match the data of the power mains. This data is found on the type plate, the packaging and in these instructions.

A Definition

  1. Aluminium casing
  2. Casing cover
  3. 2 x cross-head screws M5 x 10 mm
  4. UV-C bulb
  5. Bulb fitting for UV-C bulb
  6. Ballast with mains cable
  7. Screw sleeve
  8. Hose connection Ø 12/16 mm
  9. Hose connection Ø 16/22 mm
  10. Glass function control window
  11. Holder
  12. 4 x Fastenings screw for holder
  13. Union nut (hose safety)
  14. Status-LED
  15. Touch field

Unpacking

This device contains a UV-C bulb.

When unpacking, check that all parts have been included. For safety reasons, the UV-C bulb has been packed separately and not assembled in the unit in order to prevent breakage during transport.

CAUTION : UV-C bulb contains mercury! Handle the UV-C bulb carefully DANGER OF BREAKAGE!
Do not touch the glass body directly with fingers. Be sure to use a soft cloth or similar material.

B Assembly

Read the operating and safety instructions carefully and comply with all instructions prior to assembly.

Open both cross-head screws (3) and lift up the casing cover (2). Pull out the UV-C bulb fitting (5). Carefully put the UV-C bulb (4) into the fitting (5) until it audibly clicks in place. Carefully replace the fitting with the assembled UV-C bulb into the casing and press down firmly. Replace the casing cover and screw down firmly.

CAUTION : Never operate UV-C bulbs outside the device. Unintentional use of the device or damage to the housing UV can release dangerous UV-C radiation. UV-C radiation may damage the skin and eyes, even at low doses.

Fasten holder k and ballast f in a suitable location (e.g. in the cabinet beneath the aquarium) using the screws provided and fix UV clarifier in the holder.

CAUTION : In order to avoid any water damage, remove the filtration equipment or circulation pump before fitting the UV clarifier into the tubing system, ensuring that the piping system no longer contains any water.

Install the UV clarifier EHEIM reeflexUV+e on the discharge side (return water from external filter or from circulation pump). Slip end of hose onto the hose connection (8)(9) and secure with union nut (13). Join the hose connection with the UV clarifier by turning the screw sleeves (7) and tighten until hand- tight. Put filtration equipment or circulation pump back into operation. Follow the manufacturer’s operating instructions.

Operation

System requirement

WiFi-enabled terminal device (smartphone, tablet, notebook etc.)

Creating the network

Put the device into operation by plugging in the mains plug. Function control window (10) lights up blue.

  • The status LED n flashes white: The network is being searched for or created.
  • The status LED illuminates blue: A new network has been created.

Connecting to the WiFi network

  1. Open the network settings of your terminal device (smartphone, tablet, notebook etc.).
  2. Connect the terminal device to the WiFi network (SSID) EHEIM reeflex XXXXXXXX.
  3. Enter the network security key.

The network security key is found on the label of the ballast (6). Alternatively, you can also scan the QR code 1 (see label) to establish the connection.

Calling up the website

4. Open your web browser and enter the following address: http://192.168.1.1

Alternatively, you can also scan the QR code 2 (see label) to open the software in the browser.

Initial configuration

5. Select the desired language from the language selection and follow the instructions for the initial configuration.

Reset

Touch the touch field o with a finger for approx. 8 to 10 seconds until the status LED changes color. If the status LED lights
up green, the reset is complete and the device has been created the network again. The network security key and QR code 1
are invalid. The network can be connected to without the network security key.

Meaning of the status LED

• The status LED flashes white: The network is being searched for or created
• The status LED illuminates blue: The device is in master mode
• The status LED illuminates green: The device is connected to another EHEIM digital device.

C Cleaning and Maintenance

CAUTION : Disconnect from the mains before servicing the device. In order to avoid any water damage when cleaning and performing maintenance work, remove the filtration equipment or circulation pump before fitting the UV clarifier into the tubing system, ensuring that the piping system no longer contains any water.

Cleaning :
Disconnect the UV clarifier from the piping system by turning the screw sleeves g and removing from the holder. Clean the glass tube inside the UV clarifier at regular intervals, ideally every time the filter is cleaned, at the latest after 3 months. Pull the EHEIM Universal Cleaning Brush (Order No. 4005570) through it several times.

Maintenance :
The UV-C bulb has a maximum operating period of approx. 8,000 hours and must then be replaced. The time is displayed in the device overview of the software or communicated via email message.

Read the operating and safety instructions carefully and comply with all instructions prior to assembly.

CAUTION : Never operate UV-C bulbs outside the device. Unintentional use of the device or damage to the housing UV can release dangerous UV-C radiation. UV-C radiation may damage the skin and eyes, even at low doses.

Open both cross-head screws c and lift up the casing cover b. Remove the fitting with the UV-C bulb from the casing and carefully pull the UV-C bulb out of the bulb fitting. Carefully insert the new UV-C bulb into the fitting until it audibly clicks in place (see image B3).

CAUTION : UV-C bulb contains mercury! Handle the UV-C bulb carefully DANGER OF BREAKAGE!
Do not touch the glass body directly with fingers. Be sure to use a soft cloth or similar material.

Clearing faults

Attention! Electrocution!

  • Before clearing faults, remove the mains plug.

EHEIM reeflexUV+e 500 Microorganisms - Clearing faults

For other faults, please contact EHEIM Service.

Decommissioning and disposal

Storage

1. Uninstall the device from the aquarium
2. Clean the appliance
3. Store the appliance in a frost-proof place.

Disposal

When disposing of the appliance, heed the respective statutory regulations. Information on the disposal of electrical and electronic appliances in the European Union: Within the European Union, disposal of electrically operated appliances is governed by national regulations that are based on the EU Directive 2012/19/EU on waste electrical and electronic equipment (WEEE). The appliance may no longer be disposed of with the municipal or household waste. The appliance will be accepted free of charge at municipal collection points or recycling centres. The product packaging is made up of recyclable materials. Dispose of them in an environmentally responsible manner and take them for recycling.

Reproduction or copying – even parts there of –only with the express permission of the producer.

EHEIM GmbH & Co.KG
Plochinger Str. 54
73779 Deizisau
Germany
Tel. +49 7153/7002-01
Fax +49 7153/7002-174

www.eheim.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals