Air-Care FG0278 Triton 440 HEPA Air Purifier User Manual
- June 12, 2024
- Air Care
Table of Contents
Triton 440 HEPA Air Purifier
FG0278 Triton 440 HEPA Air Purifier
UNPACKING & INSTALLATION INSTRUCTIONS
If there is any visible external damage to the pallet or box, note this on the
shippers paperwork prior to accepting the delivery. If the contents of the
pallet are visibly damaged, refuse to accept the shipment and advise Air-Care
immediately. Remove the outer box and inspect for damage.
Report all damage immediately to your carrier. If special set-up instructions
are required, they will be taped to the outside of the equipment or in the
“Operating” section of this manual. Inspect all of the packing material for
small parts before discarding packaging material.
CHECK THAT ALL PARTS ARE PRESENT
-
Triton 440 main assembly, with wheels intact.
-
10’ power cord
Open the back door and check for the filters inside: -
Pre-Filter
-
HEPA filter
FILTERS
Pre-Filter (16” x 19” x 1”)
The pre-filter has three layers of cleaning. This filter collects most of the
larger particles that enter the purifier.
Polypropylene Mesh. This captures many larger particulates using static
electricity to capture the particles.
Polyester Fiber Mesh. This layer captures additional particles. (Part
Number F0068) Carbon Pad
This is for odor protection. (Part Number F0069)
HEPA Filter (16” x 19” x 2.5”)
The HEPA Filter included in your purifier is a medical grade filter used in
hospitals and other medical facilities due to its ability to remove 99.97% of
dust, pollen, mold, and bacteria down to .3 microns. (Part Number F60189)
SAFETY PRECAUTIONS
ALWAYS use safe and common sense precautions when working with Air-Care equipment. Do not block walkways with equipment. Remove delicate and breakable articles from the immediate work area. The following are precautions that should be reviewed by all persons who will be involved in the cleaning activity.
- Other than the filters, there are no user serviceable components in the Triton 440. Only trained technicians should attempt to make internal repairs on this equipment.
- Always turn off the main power switch on the control panel, or disconnect the power before opening or removing the back or removing the filters from the Triton 440.
- Be sure all power cords and electrical extensions are rated to meet or exceed the original Air-Care power cords (12 gauge), and inspect all AC power plug to be sure the Ground Pin is in place.
- Never connect power to Air-Care equipment unless all covers, and safety shields are in place. Mechanical and electrical parts.
- Never allow anyone except a properly trained technician to use the equipment or/and cleaning products.
- All Air-Care equipment is designed for US standard 115 volt, 60 Hz AC. Most Air-Care equipment can be special ordered to meet other worldwide standards for a reasonable price and delivery schedule. Always check the specifications on the equipment before connecting electrical power to Air-Care equipment. The Triton 440 can be special quoted for 220 Volt 50 Hz but may incur additional costs and may not provide the same performance as the 60 Hz model.
OPERATING THE TRITON 440
VERY IMPORTANT SAFETY INFORMATION
DO NOT TURN ON THE
TRITON 440 PURIFIER WITH THE ACCESS DOOR OPEN
- Place the unit in the desired location
- Before operating the unit, check to see if the fan speed knob is in the OFF POSITION
- Plug one end of the electrical cord to the socket in the back of the Triton 440
- Place the other end of the electrical cord into an electrical outlet
- Turn the speed knob clockwise to your desired fan speed setting.
CALCULATE ROOM SIZE FOR EFFECTIVE PURIFICATION
AIR EXCHANGE BASED ON ROOM SIZE
The size and number of machines depends on the volume of the space being
cleaned as well as how many Air Changes per Hour (ACH) are required by local
regulation. As a starting point, calculate the square footage of the room or
rooms, multiply by the ceiling height. It is generally recommended to have 3
to 4 air changes per hour in occupied areas
SMALL ROOMS 10’ X 10’ X 8’ = 600 CUBIC FEET = 32 EXCHANGES OF AIR PER HOUR
MEDIUM ROOMS 20’ X 20’ X 8’ = 3200 CUBIC FEET = 8 EXCHANGES OF AIR PER HOUR
LARGE ROOMS 20’ X 40’ X 8’ = 6400 CUBIC FEET = 4 EXCHANGES OF AIR PER HOUR
EXTRA LARGE ROOMS 30’ X 40’ X 8’ = 9600 CUBIC FEET = 3 EXCHANGES OF AIR PER
HOUR
The Triton 440 circulates ambient air through its filter system and exhausts
clean air into that environment.
The Triton 440 is small enough to be placed inconspicuously in a corner of a
room or beside a piece of furniture and quiet enough to not hinder normal
conversation.
Multiple units and be used larger areas to distribute the filtration without
requiring ducting in the room.
WHEN SHOULD YOU CONSIDER USING ONE OR MORE OF THESE DEVICES?
There are only a few universal regulations or standards, but to say it is all
guesswork is not at all true. On a construction site where large amounts of
fine dust are generated, it would be expected that the workers would be
wearing eye protection as well as some type of respirator to protect their
lungs. If the site was adjacent to an office with a full staff, it would be
unthinkable to start the work without a temporary barrier of plastic sheeting
to prevent the dust from covering the occupants and the office equipment. If
the dust was potentially toxic and the particles were too small to be seen by
the naked eye, even more protection for both the workers and the adjacent
occupants would be required. This is the basic reason, it is necessary to
filter the air in the work area, and to put that contaminated area in a
“Negative Pressure” condition.
The size and number of machines depends on the volume of the space being
cleaned as well as how many Air Changes per Hour (ACH) are required by local
regulation. As a starting point, calculate the square footage of the room or
rooms, multiply by the ceiling height. It is generally recommended to have 3
to 4 air changes per hour in occupied areas. To convert this requirement to a
Cubic Feet per Minute (CFM) spec for the Air Purifier, multiply the Volume of
the work area by 4 (or 3) changes/Hour then divide by 60 Minutes/Hour. To
calculate the required CFM to filter the air in a room that is 15 feet wide by
40 feet long with an 8-foot ceiling, plug in the size of the room in the
formulas for either 3 or 4 air changes per hour (ACH)As the filters become loaded, the effective cfm will drop slightly,
so be sure you have a little more capacity than the minimum.
Air Purifiers may be required to circulate and filter the air within one or
more of the contaminated areas to be collect contaminates as they are released
into the air, as well as making certain there are no “dead spots” in the
contained area where there could be a contaminate buildup.
PURIFIER MAINTENANCE
CLEANING THE OUTSIDE OF THE PURIFIER
The outside of your purifier should be cleaned occasionally with germicidal
soap and water.
THE PRE-FILTER
The prefilter/filter pad will most likely be the part that is contaiminated
the quickest as it traps larger particulates in the air.
REPLACING THE FILTER PAD
It is recommended that you wear protective clothing and gloves as this filter
will most likely be very dirty with captured contaminants.
- Remove the polypropylene mesh
- Remove the dirty pad and dispose
- Insert new pad and return the polypropylene esh.
REPLACEMENT FILTERS CAN BE PURCHASED FROM WWW.AIR-CARE.COM OR TO FIND A RETAILER NEAR YOU CALL 800-322-9919
Specification Triton 440
Weight | 65 |
---|---|
HEPA Filter (Multi-Stage) | 99.97 @ 0.3 Microns (H13) |
Pre-Fitter | Multi-Layer Electrostatic |
Charcoal VOC Filter | YES |
OZONE Free | YES |
Energy Efficiency CFM/Watt | 4. |
Input Power,120 VAC | 120 VAC |
Wattage | 230 |
Power Cord Length, w/ Ground Pin | Detachable 10 ft. |
Number of Speeds | Continuously Variable |
Motor HP | .134 HP |
CFM with Filters | 440 |
CFM Free Air | 1250 |
Exhaust Air Location | 4 Sides |
Recommend HEPA Change | 2-5 Years |
Recommend Pre-filter Change | Replace 90-120 days with included Pads up to 18 |
months supply.
Sound Level dB| 15-55
Dimensions| 19.5 x 19.5 x 24
Casters| 4 x 2″ Locking Swivel
Construction| Powder Coated Steel
Air Changes Per Hour In 1,300 ft’| 3.25 ACH
Removes Particles Related to Allergies, Asthmas, etc.| YES
Made is USA| YES
Warranty| Limited Lifetime
Manufacturer Recommended Application| Healthcare Facilities, Schools, Offices,
Homes
EPA OZONE FREE (CARB)| YES
ETU UL| YES
CARB| YES
AHAM Verified (CADR)| YES
Energy Star| YES
*E.P.A. Establishment Number: 96893-NV-1
Part # FG0189 HEPA 16” x 19”x 2.5” Filter
Part # F0068 – Replacement Pads 16×19
Part # F0069 Carbon Filter 16×19
UPC # 00855303007481
5 pack –UPC 00855303007863
3 pack- UPC 00855303007856
LIMITED LIFETIME WARRANTY TRITON 440
Air-Care warrants this product to be free from defects in materials and
workmanship to the original purchaser from the date of purchase.
Warranty covers both parts and labor (labor is to be performed at Air-Care’s
facility located at 3868 E. Post Road, Las Vegas, Nevada).
Warranty is extended to the original purchaser and is not transferable.
This warranty does not extend to any damage to a product caused by or
attributable to freight damage, abuse, misuse, improper or abnormal usage.
Warranty is also void if the product has been modified or altered in any way.
The purchaser is responsible for the cost of shipping the equipment to Air-
Care’s facility for evaluation. If found to be defective and covered by the
terms of this warranty, Air-Care will pay ground shipping charges on the
repaired or replaced item back to the purchaser’s location. Any additional
expedited service charges for quicker shipping shall be born by the purchaser.
If the product or component is not found to be a warranty issue, the purchaser
will be responsible for return shipping charges.
Air-Care is not responsible or liable for indirect, special, or consequential
damages arising out of or in connection with the use of performance of the
product; damages with respect to any economic loss, loss of property, loss of
revenues or profits, loss of use, or other incidental or consequential damages
of whatsoever nature.
The warranty extended hereunder is in lieu of any and all other warranties,
and any implied warranties of any type.
This warranty gives you specific rights. These rights and others vary from
state to state.
Division of D.P.L. Enterprises Inc.
3868 East Post Road, Las Vegas, Nevada 89120,
702-454-5515, FAX
702-454-5225
Website: www.air-care.com;
E-mail:Info@Air-Care.com
2022 DPL ENTERPRISES
Documents / Resources
| Air-
Care FG0278 Triton 440 HEPA Air
Purifier
[pdf] User Manual
FG0278 Triton 440 HEPA Air Purifier, FG0278, Triton 440 HEPA Air Purifier, 440
HEPA Air Purifier, HEPA Air Purifier, Air Purifier, Purifier
---|---