TECH CONTROLLERS EU-292n v3 Two State with Traditional Communication User Manual
- June 12, 2024
- TECH CONTROLLERS
Table of Contents
- TECH CONTROLLERS EU-292n v3 Two State with Traditional Communicationm
- Product Information
- Product Usage Instructions
- SAFETY
- DEVICE DESCRIPTION
- **Two colour versions available
- HOW TO INSTALL THE CONTROLLER
- FIRST START-UP
- HOW TO USE THE CONTROLLER
- HEAT/ COOL mode
- TECHNICAL DATA
- Declaration of conformity
- CONTACT
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TECH CONTROLLERS EU-292n v3 Two State with Traditional Communicationm
Product Information
- Product Name: EU-292n v3
- Product Type: Room Regulator
- Description: The EU-292n v3 room regulator is designed for controlling heating or cooling devices such as gas, oil, or electric boilers or boiler controllers. Its main function is to maintain the preset temperature in the room by sending a signal to the heating/cooling device when the desired temperature is reached. It offers advanced software that enables various functions including maintaining the preset room temperature, manual mode, day/night program, weekly control, and underfloor heating system control (additional temperature sensor required).
Controller Equipment:
- Touch buttons
- Front panel made of 1mm glass
- Built-in temperature sensor
- Batteries
Display Versions:
- Standard (black text on white background)
- Negative (white text on black background)
Product Usage Instructions
- Installation: The device should be installed by a qualified electrician. Follow the connection diagram provided in the user manual.
- Connect the room regulator to the heating device using a two-core cable. If connecting devices with a power greater than 1A, use a contactor. Optionally, an additional sensor can be connected to the floor sensor contact for additional functions.
- First Start-Up: Follow these steps for the first start-up of the EU-292n v3 controller:
- Insert the batteries by removing the controller back cover.
- If the room regulator is controlling a floor heating system, connect an additional sensor to the floor sensor connector.
- Connect the regulator to the heating device using a two-core cable.
- Controller Operation Modes: The room regulator can operate in the following modes:
- Maintaining the preset room temperature
- Manual mode
- Day/Night program
- Weekly control
- Floor Heating Functions: In order to access floor heating functions in the controller menu, an additional sensor must be connected to the floor sensor contact.
SAFETY
Before using the device for the first time the user should read the following
regulations carefully. Not obeying the rules included in this manual may lead
to personal injuries or controller damage. The user’s manual should be stored
in a safe place for further reference.
In order to avoid accidents and errors it should be ensured that every person
using the device has familiarized themselves with the principle of operation
as well as security functions of the controller. If the device is to be sold
or put in a different place, make sure that the user’s manual is there with
the device so that any potential user has access to essential information
about the device. The manufacturer does not accept responsibility for any
injuries or damage resulting from negligence; therefore, users are obliged to
take the necessary safety measures listed in this manual to protect their
lives and property.
WARNING
- A live electrical device! Make sure the regulator is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.)
- The device should be installed by a qualified electrician.
- The device should not be operated by children.
WARNING
- The device may be damaged if struck by a lightning. Make sure the plug is disconnected from the power supply during a thunderstorm.
- Any use other than specified by the manufacturer is forbidden.
- The device should be periodically checked.
Changes in the merchandise described in the manual may have been introduced subsequent to its completion on 11.10.2022. The manufacturer retains the right to introduce changes to the structure or colours. The illustrations may include additional equipment. Print technology may result in differences in the colours shown. We are committed to protecting the environment. Manufacturing electronic devices imposes an obligation of providing for environmentally safe disposal of used electronic components and devices. Hence, we have been entered into a register kept by the Inspection for Environmental Protection. The crossed-out bin symbol on a product means that the product may not be disposed of to household waste containers. Recycling of waste helps to protect the environment. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.
DEVICE DESCRIPTION
The EU-292n v3 room regulator is intended for controlling the heating or cooling device (e.g. gas, oil or electric boiler or the boiler controller). Its main task is to maintain the pre-set temperature in the flat by sending a signal to the heating/cooling device (contact opening) when the desired temperature is reached.
Advanced software enables the regulator to fulfil a wide range of functions:
- maintaining the pre-set room temperature
- manual mode
- day/night program
- weekly control
- underfloor heating system control (optional; an additional temperature sensor is necessary)
Controller equipment:
- touch buttons
- front panel made of 1mm glass
- built-in temperature sensor
- batteries
The EU-292n v3 room regulator offers two display versions:
- standard (the data is displayed in black against white background)
- negative (the data is displayed in white against black background)
**Two colour versions available
**
HOW TO INSTALL THE CONTROLLER
NOTE: The device should be installed by a qualified electrician.
The EU-292n v3 room regulator – connection diagram
The room regulator should be connected with the heating device with the use of
a two-core cable. When connecting devices with a power greater than 1A, it is
necessary to use a contactor. Optionally, it is possible to connect an
additional sensor to the floor sensor contact contact – additional functions
will appear in the controller menu.
FIRST START-UP
In order for the EU-292n v3 controller to operate correctly, follow these steps when starting the device for the first time:
- Insert the batteries – in order to do it, remove the controller back cover.
- If the room regulator is to control the floor heating system, connect an additional sensor to the floor sensor connector.
- Connect the regulator with the heating device using a two-core cable.
HOW TO USE THE CONTROLLER
PRINCIPLE OF OPERATION
The EU-292n v3 room regulator is designed to maintain the pre-set room
temperature by sending a signal to the heating/cooling device (contact
opening) when the pre- set room temperature has been reached. After receiving
such a signal, the heating/cooling device is disabled (if it is connected to a
CH boiler controller, the CH boiler switches to sustain mode after receiving
the signal).
If the regulator is used in heating mode, it may also cooperate with a floor
sensor. In such a situation, the contact remains closed when the floor
temperature is below the minimum threshold. After the threshold temperature
has been exceeded, the contact remains closed until the pre-set room
temperature is reached. If the floor sensor temperature exceeds the maximum
value, the controller will open the contact regardless of the current room
temperature.
NOTE: In order for the floor heating functions to be available in the
controller menu, an additional sensor must be connected to the floor sensor
contact.
OPERATION MODES
The room regulator may operate in one of the following operation modes:
- Day/night mode
In this mode the pre-set temperature value depends on the current time of the
day. The user may set different temperature values for the daytime and
nighttime (comfort temperature and economical temperature) as well as define
the exact time of entering day mode and night mode.
In order to activate this mode, press EXIT button until day/night mode icon
appears on the main screen.
- Weekly control
This mode enables the user to define the time when the pre-set comfort temperature and the pre-set economical temperature will apply. The user may set 9 different programs divided into three groups:
- PROGRAMS 1÷3 – daily temperature values are set for all days of the week;
- PROGRAMS 4÷6 – daily temperature values are set separately for the weekdays (Monday-Friday) and for the weekend (Saturday-Sunday);
- PROGRAMS 7÷9 – daily temperature values are set for each day of the week separately.
The display shows the hours when the comfort temperature applies. In the
remaining time period economic temperature applies.
In order to activate this mode, press EXIT until a weekly control icon appears
on the main screen.
- Manual mode
In this mode the pre-set temperature is adjusted manually from the main screen
view with the use of these buttons: UP DOWN Manual mode is activated
automatically when one of these buttons is pressed. Once the manual mode is
activated, the previous operation mode enters sleep mode until the next pre-
programmed temperature change. The manual mode may be deactivated by pressing
the EXIT button.
Example 1 – manual mode activation in Day/night mode
When Day/night mode is active, the user changes the pre-set temperature by
pressing one of the buttons UP DOWN which automatically activates manual mode.
The controller returns to Day/night mode when daytime changes into nighttime
(or the other way round) or when the user presses EXIT.
Example 2 – manual mode activation in weekly control mode
When Weekly control is active, the user changes the pre-set temperature by
pressing one of the buttons UP DOWN which automatically activates manual mode.
The controller returns to weekly control mode when, according to the weekly
schedule, economical temperature changes into comfort temperature (or the
other way round) or when the user presses EXIT.
MAIN SCREEN VIEW AND DESCRIPTION
The user operates the device using touch buttons. While one parameter is being
edited, the remaining icons are not displayed.
- Display
- EXIT in the main screen view – press this button to activate the weekly control or day/night mode. In the controller menu, use this button to confirm the settings and return to the main screen view.
- UP in the main screen view – press this button to switch to manual mode and decrease the pre-set temperature value. In the controller menu, use this button to change parameter settings, enter the service code, etc.
- DOWN in the main screen view – press this button to switch to manual mode and increase the pre-set temperature value. In the controller menu, use this button to change parameter settings, enter the service code, etc.
- MENU – hold this button to enter the controller menu. While editing parameters, press this button to confirm the changes and move on to edit the next parameter.
EU-292n User manual
- Day of the week
- An icon informing about the current economical temperature (resulting from weekly control or day/night mode settings).
- An icon informing about the current comfort temperature (resulting from weekly control or day/night mode settings).
- An icon informing about displaying the current floor temperature (point 6 on the display) – a floor sensor must be and registered in the controller menu.
- Floor temperature
- Pre-set room temperature
- Time
- Buttery level
- An icon informing about room cooling/heating. The animation differs depending on the selected operation mode:
- Heating mode – the icon flashes when the pre-set temperature has not been reached; it is steady when the pre-set temperature has been reached.
- Cooling mode – the icon rotates when the temperature is above the pre-set value; it is steady when the pre-set temperature has been reached.
- Current operation mode:
- a. Weekly
- b. Manual
- c. Day/night
- Current room temperature
- Parameter icons (see: a table below)
CONTROLLER FUNCTIONS
The user navigates the menu structure using UP DOWN, EXIT and MENU. In order
to edit particular parameters, press MENU. Next, press MENU to view the
controller functions – the edited parameter is flashing whereas the remaining
parameters are not displayed. Use UP DOWN to change the parameter settings.
Press MENU to confirm the changes and move on to edit the next parameter or
press and EXIT to confirm the changes and return to the main screen view.
BLOCK DIAGRAM – MAIN MENU *These functions are displayed only
after the additional sensor has been connected to the floor sensor contact and
activated in the controller menu by selecting ON in the Floor sensor submenu.
DAY OF THE WEEK
After entering the main menu, all icons which are not connected with the
parameter which is being edited are not displayed. The first parameter is day
of the week. Press UP or DOWN until the current day of the week is displayed.
Press MENU to confirm and move on to the next parameter or press EXIT to
confirm and return to the main screen view.
CLOCK SETTINGS
In order to set current time, press MENU until the time setting panel is
displayed on the screen. By pressing UP or DOWN setting the hour and minutes.
Press MENU to confirm and move on to the next parameter or press EXIT to
confirm and return to the main screen view. DAY FROM…
This function enables the user to define the exact time of entering the day
mode. When Day/night mode is active, comfort temperature applies at the
daytime. To configure this parameter press MENU until Day from… setting
appears on the screen. By pressing UP or DOWN set the hour and minute of day
mode activation. Press MENU to confirm and move on to the next parameter or
EXIT to confirm and return to the main screen view.
NIGHT FROM…
This function enables the user to define the exact time of entering the night
mode. When Day/night mode is active, economical temperature applies at
nighttime.To configure this parameter press MENU until Night from… setting
appears on the screen. By pressing UP or DOWN set the hour and minute of night
mode activation. Press MENU to confirm and move on to the next parameter or
press EXIT to confirm and return to the main screen view.
BUTTON LOCK
In order to activate the button lock, press MENU until a padlock icon appears.
Use one of the buttons UP or DOWN to select ON. In order to unlock the
buttons, press and hold the buttons at the same time, select the button UP
DOWN lock function and select OFF.
OPTIMUM START
Optimum start is an intelligent system controlling the heating/cooling
process. It involves constant monitoring of the heating/cooling system
efficiency and using the information to activate the heating/cooling in
advance in order to reach the pre-set temperatures.
A – pre-programmed change from economical temperature to comfort temperature Activating this function means that at the time of pre-programmed change of the pre-set temperature determined by the schedule, the current room temperature will be close to the desired value. In order to activate this function, press MENU until Optimum start settings appear. Use the buttons UP DOWN to activate/deactivate the function. Press MENU to confirm and move on to the next parameter or press EXIT to confirm and return to the main screen view.
AUTOMATIC MANUAL MODE
This function enables manual mode control. If this function is active (ON),
the manual mode is disabled automatically when a pre-programmed change
resulting from the previous operation mode is introduced. If the function is
disabled (OFF), the manual mode remains active regardless of the pre-
programmed changes.
WEEKLY CONTROL
This function is used to change the current weekly control program and edit
the weekly programs.
HOW TO CHANGE WEEKLY PROGRAM NUMBER
When weekly control is enabled (see: VII.2. Operation modes) the current
program is activated. In order to choose the program number, press MENU until
weekly program settings appear on the screen. By pressing and holding MENU
button the user opens up the program selection screen. Each time the user
holds the MENU button, the program number changes. When the desired number
appears on the screen, press MENU – the controller returns to the main screen
view and the selected program number is set.
HOW TO CONFIGURE PARTICULAR WEEKLY PROGRAMS
Weekly program allows the user to define the time when comfort temperature and
economical temperature will apply. Depending on the program number, the user
may set daily temperature values for all days of the week (programs 1÷3), for
weekdays and the weekend separately (programs 4÷6) and for each day of the
week separately (programs 7÷9). In order to edit weekly program, press MENU
until weekly program setting screen opens up.
STEP 1 – CHOOSE THE PROGRAM TO BE EDITED
By pressing and holding MENU button the user opens up the program editing
screen. Each time the user holds the MENU button, the program number changes.
When the desired number appears on the screen, the user may start editing its
parameters.
STEP 2 – SELECT DAYS OF THE WEEK
If the user wants to edit programs 1÷3, there is no possibility of selecting
particular days of the week as the setting applies to each day. If the user
wants to edit programs 4÷6 , it is possible to edit the settings for weekdays
and the weekend separately. Press MENU briefly in order to select.
If the user wants to edit programs 7÷9, it is possible to edit the settings for each day separately. Press MENU briefly in order to select a day.
STEP 3 – ASSIGN COMFORT TEMPERATURE OR ECONOMICAL TEMPERATURE TO PARTICULAR
HOURS
An hour which is being edited is displayed on the controller screen. In order
to assign comfort temperature, pressUP . In order to select economical
temperature, press DOWN. The controller automatically moves on to editing the
next hour.
The parameters of the weekly program are displayed at the bottom of the
screen: hours to which comfort temperature has been assigned are displayed
whereas hours to which economical temperature has been assigned are not
displayed.
Example: The following screenshot presents daily settings of program no.
7 for Monday
- 00⁰⁰-00⁵⁹- economical temperature
- 01⁰⁰-08⁵⁹- comfort temperature
- 09⁰⁰-14⁵⁹- economical temperature
- 15⁰⁰-21⁵⁹- comfort temperature
- 22⁰⁰-23⁵⁹- economical temperature
NOTE: When the user finishes the editing process by pressing EXIT button, the controller returns to the main screen view and this program is selected as the current program.
PRE-SET COMFORT TEMPERATURE
Pre-set comfort temperature is used in weekly control mode and day/night mode.
Press MENU button until the comfort temperature change screen opens up. Press
UP or DOWN to set the desired temperature. Press MENU to confirm and move on
to the next parameter or press EXIT to confirm and return to the main screen
view.
PRE-SET ECONOMICAL TEMPERATURE
Pre-set economical temperature is used in weekly control mode and day/night
mode. Press MENU button until the economical temperature change screen opens
up. Press UP or DOWN to set the desired temperature. Press MENU to confirm and
move on to the next parameter or press EXIT to confirm and return to the main
screen view.
PRE-SER TEMPERATURE HYSTERESIS
Room temperature hysteresis defines the pre-set temperature tolerance in order
to prevent undesired oscillation in case of small temperature fluctuation
(within the range of 0,2 ÷ 4°C). In order to set the hysteresis, press MENU
until the hysteresis setting screen opens up. Use UP or DOWN to set the
desired hysteresis value. Press MENU to confirm and move on to the next
parameter or press EXIT to confirm and return to the main screen view.
Example:
- Pre-set temperature : 23°C
- Hysteresis : 1°C
The room regulator reports that the temperature is too low only when the room
temperature drops to 22 °C.
TEMPERATURE SENSOR CALIBRATION
Calibration should be performed while mounting or after the regulator has been
used for a long time, if the room temperature measured by the internal sensor
differs from the actual temperature. Calibration setting range is from -10 to
+10 ⁰C with the accuracy of 0,1⁰C. To calibrate the built-in sensor, press the
MENU button until the temperature sensor calibration screen appears. Use the
buttons to set the desired correction. To confirm, press UP or DOWN the MENU
button (confirm and go on to edit the next parameter) or press EXIT to confirm
and return to the main screen view.
FLOOR SENSOR
Use one of the buttons to enable the floor sensor (ON) or disable it (OFF). To
confirm, press UP DOWN the MENU button (confirm and go on to edit the next
parameter) or press EXIT to confirm and return to the main screen view.
NOTE: It is necessary to set this function to ON in order for the following parameters to be available in the controller menu: maximum floor temperature, floor sensor hysteresis, minimum floor temperature.
MAXIMUM FLOOR TEMPERATURE
In order to set the maximum floor temperature, enable floor heating and press
MENU until the maximum floor temperature screen opens up. Next, use or to set
the maximum temperature. To confirm, press the MENU button (confirm and go on
to edit the next parameter) or press EXIT to confirm and return to the main
screen view.
NOTE It is necessary to set this function to ON in order for the following parameters to be available in the controller menu: maximum floor temperature, floor sensor hysteresis, minimum floor temperature.
MAXIMUM FLOOR TEMPERATURE
In order to set the maximum floor temperature, enable floor heating and press
UP OR DOWN MENU until the maximum floor temperature screen opens up. Next, use
or to set the maximum temperature. To confirm, press the MENU button (confirm
and go on to edit the next parameter) or press EXIT to confirm and return to
the main screen view.
MINIMUM FLOOR TEMPERATURE
In order to set the minimum floor temperature, enable floor heating and press
UP OR DOWN MENU until the minimum floor temperature screen opens up. Next, use
or to set the minimum temperature. To confirm, press the MENU button (confirm
and go on to edit the next parameter) or press EXIT to confirm and return to
the main screen view.
FLOOR TEMPERATURE HYSTERESIS
Floor temperature hysteresis defines the pre-set temperature tolerance in
order to prevent undesired oscillation in case of small temperature
fluctuation within the range of 0,2 ÷ 4°C. In order to set the hysteresis,
press UP OR DOWN MENU until the hysteresis screen opens up. Next, use or to
set the hysteresis. To confirm, press the MENU button (confirm and go on to
edit the next parameter) or press EXIT to confirm and return to the main
screen view.
Example:
- Pre-set temperature: 23°C
- Hysteresis: 1°C
The room regulator reports that the temperature is too low only when the room temperature drops to 22 °C.
SERVICE MENU
Certain controller functions are secured with a code. They can be found in the
service menu. In order to introduce changes in the service menu settings,
press UP DOWN MENU until Service menu settings screen opens up. Next, use the
buttons to enter the code – 215. Select the first digit – 2 and confirm by
holding the Menu button until the next digit starts flashing. Follow in the
same way with the remaining digits of the code. Press MENU to confirm.
HEAT/ COOL mode
This function enables the user to select the operation mode of the room regulator:
- COOL – controlling a cooling system
- HEAT – controlling a heating system
Use the buttons UP DPWN to select the type of system to be controlled. To confirm, press the MENU button (confirm and go on to edit the next parameter) or press EXIT to confirm and return to the main screen view.
NOTE: Cooling mode mustn’t be selected in the case of using a floor sensor – it may lead to underfloor system damage.
How to edit the minimum (T1) and maximum (T2) pre-set temperature This function enables the user to set the minimum (T1) and the maximum (T2) pre-set room temperature. Select this option – the parameter starts flashing. Use the buttons UP DPWN to set the temperature. To confirm, press the MENU button (confirm and go on to edit the next parameter) or press EXIT to confirm and return to the main screen view.
Optimum start calibration
Optimum start calibration starts when the controller detects the heating
needed in order to reach the pre-set temperature, with the Optimum start
function turned on.
DEF factory settings
This function enables the user to restore factory settings. In order to do it,
select the Def function and press MENU to confirm. Next, use the buttons UP
DPWN to select YES and confirm by pressing MENU.
TECHNICAL DATA
EU-292n v3
Power supply| 2xAA, 1,5V batteries
Range of room temperature setting| 5oC ÷ 35oC
Potential-free cont. nom. out. load| 230V AC / 0,5A (AC1) *
24V DC / 0,5A (DC1) **
Accuracy of measurement| +/- 0,5oC
AC1 load category: single-phase, resistive or slightly inductive AC load. ** DC1 load category: direct current, resistive or slightly inductive load. The pictures and diagrams are for illustration purposes only. The manufacturer reserves the right to introduce some hanges.
Declaration of conformity
Hereby, we declare under our sole responsibility that EU-292n v3 manufactured by TECH STEROWNIKI, head-quartered in Wieprz Biała Droga 31, 34-122 Wieprz, is compliant with Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits (EU OJ L 96, of 29.03.2014, p. 357), Directive 2014/30/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of Member States relating to electromagnetic compatibility (EU OJ L 96 of 29.03.2014, p.79), Directive 2009/125/EC establishing a framework for the setting of ecodesign requirements for energy-related products as well as the regulation by the MINISTRY OF ENTREPRENEURSHIP AND TECHNOLOGY of 24 June 2019 amending the regulation concerning the essential requirements as regards the restriction of the use of certain hazardous substances in electrical and electronic equipment, implementing provisions of Directive (EU) 2017/2102 of the European Parliament and of the Council of 15 November 2017 amending Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (OJ L 305, 21.11.2017, p. 8). For compliance assessment, harmonized standards were used: PN-EN IEC 60730-2-9:2019-06, PN-EN 60730-1:2016-10.
CONTACT
- Central headquarters: ul. Biata Droga 31, 34-122 Wieprz
- Service: ul. Skotnica 120, 32-652 Bulowice
- phone: +48 33 875 93 80
- e-mail: serwis@techsterowniki.pl.
- www.tech-controllers.com.
Read User Manual Online (PDF format)