Dear Customer,
Thank you for choosing a VMAX Power generator! VMAX portable generators
feature advanced lithium-ion battery technology and are an ideal portable
power supply solution for indoor and outdoor activities. VMAX Power Generators
are great for camping, tailgating and other outdoor activities. Furthermore,
they can also be used as critical backup power in an emergency. Please
carefully read and follow the instructions before using VMAX portable
generators. Please use the included charger to fully charge your VMAX
portable generator. Please read this manual before using your VMAX portable
generator.
What’s inside the box
Packing List
| VPG750
---|---
| Charger
| Manual
Optional Accessories
| Solar Panel
---|---
| 5-in-1 USB cable
| DC Light
VPG750 Parts List
- ON/OFF power switch
- LCD screen
- AC Charger input
- Solar charging input
- USB outputs
- 12V DC outputs
- Cigar lighter output
- AC output button
- AC output indicator
- AC outputs
- Cooling fan
- Light
- Light button
- Handle
Using the VPG750
- When battery capacity is below 20%, AC outputs will be automatically disabled.
- When battery capacity is below 5%, DC (USB & 12V) outputs will be automatically disabled.
- When DC is in use or AC is on, the discharging indicator on the right side of LCD screen will rotate ( ).
Power On
Press for 3 seconds to turn on the VPG750.
During the start-up process, all the icons on the LCD screen will display.
The LCD screen will turn to normal display if all functions are normal.
Using AC Output
Press the AC output button, an LED indicator will illuminate and the AC output
icon ( ) on the LCD screen will be activated, the AC ports are now active.
When you finish using AC ports, press the AC output button to turn off the AC
output.
The interval time between pressing AC output button on/off should not be less
than 5 seconds.
Using 5V Output
USB outputs can be used to charge your devices. When the VPG750 detects the load, the USB icon ( ) on the LCD screen will be activated. The VPG750 has both USB-A and Type-C ports. Please see the technical specifications for output parameters on Page 9.
Using 12V DC Output
12V DC outputs can be used directly to charge your DC devices. When the
VPG750 detects the load, the DC icon ( ) on the LCD screen will be
activated.
Using 12V DC Cigar Lighter Output
12V DC cigarette lighter outputs can be used directly to charge your
devices. When the VPG750 detects the load, the 12V DC cigarette lighter icon (
) on the LCD screen will be activated. The maximum output power is
96W.
Lighting
The VPG750 has 5 lighting modes:
High brightness (100% power), Normal (50% power), Energy saving (25% power),
Emergency flash and SOS. Press the light button hard to turn the light on/off,
and prgently to shift between different modes.
Power Off
When finished using your VPG750, please power it off by following these steps:
- Remove all the connected cables and loads.
- Press the AC Output button to turn off the AC output.
- Press and hold the ON/OFF button for 3 seconds to switch off.
Recharging
-
Wall Charging
Important: Please do not discharge your VPG750 while charging! -
Solar ChargingPlace solar panels toward the sun at a proper angle to significantly improve solar charging efficiency.
The following estimated charging times are based on the most ideal conditions:
Model| 40W Input| 60W Input| 80W Input| 100W Input|
120W Input
---|---|---|---|---|---
VPG750| 20hrs-25hrs| 12hrs-15hrs| 10hrs-12hrs| 8hrs-10hrs| 10hrs-12hrs
LCD Screen Guide
-
Battery
Battery Power Indicator -
Output
USB in use
12V DC in use
12V Cigarette Lighter in use
AC Power Indicator
Icon rotates when DC power is in use or AC is on -
Input
Solar Charging
AC Charging
Charging Indicator -
Warning States
Item | Buzzer | Icon Display | Causes |
---|---|---|---|
1 | One buzzing sound every 3 seconds and buzzing stops after 30 seconds. | ||
Battery icon flashes | Flashes for 30 seconds and then ceases when battery |
capacity ≤20%; Flashes continuously when battery capacity≤5% .
2
| | Battery and AC output icons flash, and current power display will restore
after buzzing stops.| AC output is locked when battery capacity ≤20%
3
| Battery and cigar lighter icons flash| Use cigar lighter output when battery
capacity ≤5%
4
| Battery and 12V DC icons flash| Use 12V DC output when battery capacity ≤5%
5
| Battery and USB icons flash| Use USB output when battery capacity ≤5%
6| Three buzzing sounds every 3 seconds and buzzing stops after 30 seconds.| |
| Warning and solar input icons flash| AC charging failure caused by one of
any following reasons:
- Charging voltage is out of allowable range;
2)Charging current is beyond the max. allowable value;
3)Solar charging port is over-temperature.
7| | Warning and charger icons flash| Charging failure caused by one of any following reasons: - Charging voltage is out of allowable range;
- Charging current is beyond the max. allowable value;
- AC charging port is over-temperature.
| Warning and AC icons flash| AC output failure caused by one of any following reasons: - Overload;
- Short-circuit;
- Inverter is protected due to over-temperature;
- Communication between inverter and display board is interrupted.
8
9| Three buzzing sounds every 3 seconds and buzzing stops after 30 seconds.| | .| Warning and cigar lighter icons flash| Cigar output failure caused by one of any following reasons: - Overload;
- Short-circuit.
---|---|---|---|---|---
| Warning and 12V DC
icons flash
12V DC port.| 12V DC output failure caused by one of any following reasons: - Overload;
- Short-circuit;
- Reverse plug through
10
ii| | Warning and USB icons h flash| USB output failure caused by one of any following reasons: - Overload;
- Short-circuit;
- Over-voltage.
12| | Warning and Battery icons flash(power icon
normally displays)| Communication between battery voltage acquisition board and display board is interrupted.
13| | Warning, Battery and Power icons flash (power icon displays current power)| Battery alarm due to over-temperature protection or low-temperature protection.
Troubleshooting
No. | Faults | Causes | Solutions |
---|---|---|---|
1 | Power-up Failure | Under-voltage Protection | Please charge VPG750. |
Abnormal Load Protection | Please remove the loads and recharge VPG750. If the |
problem can not be solved, please ask for customer service.
Product Failure| Please contact VMAX USA for repair or replacement
2| Charger Fault| Unmatched Charger| Please only use the authorized charger.
Charger Failure| Please contact your local dealer to replace the charger.
Abnormal Power Supply or Connection| Please re-connect the charger. If the
problem cannot be solved, please contact your local dealer to replace the
charger.
3| Solar Panel Charging Fault| Over-voltage| Please use the recommended PV
panel.
Weak Sunlight| Please charge in sunny place.
Solar Panel Failure| Please contact your local dealer to replace the PV panel.
Abnormal Wiring-harness Connection| Please re-connect the wiring-harness.
If the problem can not be solved, please contact your local dealer to replace
the PV panel.
4| DC / AC Output Fault| Battery Under-voltage Protection| Please charge
VPG750.
Discharge Over-current Protection| Please check and ensure the powerof loads
are within the allowed range.
Over-temperature Protection| Please turn off VPG750. and restart after cooling
down.
Product Failure| Please contact VMAX USA for repair or replacement
5| Abnormal Icon Display| Abnormal Loads| Please remove the loads.
---|---|---|---
Hardware Fault| Please contact VMAX USA for repair or replacement
LCD Screen Failure| Please contact VMAX USA for repair or replacement
6| LCD Screen Fault| LCD Screen Failure| Please contact VMAX USA for repair or
replacement
Specifications
Capacity | VPG750: 786.24Wh (10.8V/ 72.8Ah) |
---|---|
Weight | VPG750: 16.5Ibs (7.5kg) |
Dimensions | 13.7 x 6.3 x 11.2 in(349 x 160 x 285 mm) |
Charger Input | VPG750:AC Wall Charger 12.6V/ 10A |
Solar Input | 12.5V-25V / Max. Power up to 125W |
USB Output | 2 x 5V 2.4A/ 9V 2A/ 12V 1.5A |
USB Type-C | 2 x 20V 3.25A / 15V 3A / 12V 3A/ 9V 3A/ 5V 3A |
DC Output | 2 x 12V **** 5A / 60W |
Cigar Lighter | 1 x 12V **** 10A / 120W |
AC Output | 2 x 230V/ 50Hz or 2 x 110V / 60Hz |
VPG750: 500W
Lighting| 1W High Brightness LED with SOS mode
Temperature| Working: -10 – 45°C (14 – 113°F)
Storage: 0 – 45°C (32 to 113°F)
Model| 12V 3W
Lighting| Stereo| PSP| Canera| Smart
Phone| Tablet| Laptop| 60W Fan| TV| Mini
Bar
---|---|---|---|---|---|---|---|---|---|---
VPG750| 230h+| 500X+| 90X+| 160X+| 70X+| 17X+| 8X+| 12h+| 7h+| 15h+
| 12V 3W Lighting
---|---
| Stereo
| PSP
| Camera
| Smart phone
| Tablet
| Laptop
| 60W Fan
| TV
| Mini Bar
Attentions
| Please use VPG750 to power/charge your devices within the following
operating temperature range: 14°F (-10°C) to 113°F (45°C)
---|---
| Please recharge VPG750 within the following operating temperature range32°F
(0°C) to 113°F (45°C). Do not charge VPG750 when ambient temperature is above
113°F (45°C).
| Please do not recharge VPG750 more than 12 hours, overcharging may shorten
the service life.
| Please use the included charger when charging via an AC wall outlet.
| To maximize the service life of your VPG750, do not discharge below 20%
state of charge. Note: Discharging below 20% is acceptable.
| Please do not expose VPG750 to fire or high temperature (under direct
sunlight or in vehicle under high heat), which may cause accidents such as
fire and explosion.
| Please recharge or use VPG750 at least once every four months for a longer
service life.
| Please ensure close supervision when using VPG750 around children or pets.
| Please do not take on planes or aircraft.
| Please do not disassemble, this may lead to risks such as fire, explosion,
or electric shock.
| Please avoid dropping VPG750.
| Please charge and use in a dry and well ventilated area to avoid rain and
water. Do not restrict ventilation in any way.
Warranty
Limited Warranty Conditions:
- The warranty is only valid if the product is used and handled correctly as per the included instructions.
- The warranty starts from the purchasing date. To make a warranty claim you must present the original invoice or sales receipt as evidence of your purchase.
- If any fault or failure happens, please contact the authorized seller or contact us directly to arrange a repair or replacement.
- The warranty is limited to the original purchaser when purchased from an authorized seller. The warranty is not transferable.
Warranty Exclusions:
- Warranty period exceeded.
- No valid purchase voucher (like invoice, etc.) can be provided.
- Repaired or modified by unauthorized agency or individual.
- Damage caused by using the unauthorized accessories, or not using the included charger.
- Damage caused by improper transportation, usage, operation, or storage.
- Damage caused by lightning, abnormal voltage, flood, fire, natural disaster, or accidental breakage, etc.
- Damage caused if used in environments where it is not intended for.
- Warranty does not apply to the battery cell unless the battery cell is fully charged within 30 days after your purchase and at least once every 6 months thereafter.
Disposal
Properly recycle your device at the end of its service life. Please dispose batteries by following local regulations.
Customer Service
18-month Limited Warranty
Lifetime Technical Support
Please contact us or visit our website for more information.
VMAX USA
5850 Sheldon Rd, Belleville, Mi 48111
1-888-862-9826
info@vmaxtanks.com
vmaxtanks.com
All rights reserved.
Documents / Resources
|
VMAXTANKS VPG750 Portable Power
Generator
[pdf] User Manual
VPG750 Portable Power Generator, VPG750, Portable Power Generator, Power
Generator, Generator
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>