CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm Instruction Manual

June 12, 2024
CLIPSAL

CLIPSAL Firetake LOGO Smoke alarm
755LPSMA4
Lithium Battery Powered Photoelectric Smoke
Alarm with Wireless InterconnectCLIPSAL 755LPSMA4 Lithium Battery Powered
Photoelectric Smoke Alarm

More information is available

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm - QR
Code https://download.schneider-electric.com/files?p_Doc_Ref=EAV8159103

Scan the QR code for more information about your Clipsal smoke alarm:

  • What smoke alarms can and cannot do
  • Developing and practising a plan of escape
  • What to do if an alarm sounds.

Operating elements

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Operating elements

Installation location

Install more than 1 m away from air conditioner/heater vents and fans, electrical sources, appliances and fittings.

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Installation 1

Do not install in garages, kitchens, bathrooms or any area with high levels of moisture, dirt or insects.

For garages: A heat alarm is more suitable as it is not affected by particulates.
Dead air space (do not install in these locations)
Suitable alarm location

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Installation 3

Example: Class 1a building
 Smoke alarm
Recommended additional alarms (or as required by legislation)

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Installation 4

Example: Class 1b building
Smoke alarm
Smoke alarm with evacuation lighting

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Installation 5

Storeys with bedrooms:
Alarm in hallway connecting bedrooms
Recommended additional alarms (or as required by legislation)

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Installation 6

Storeys with no bedrooms:
Alarms located in the area of the stairway.

Installation

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm -
Installation 11

Removing alarm from bracket
Use a flat-bladed screwdriver to press and hold locking clip upwards…

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm - alarm
bracket

Interconnected alarms (do this before mounting alarms)
Preparing the MASTER alarm

Choose a smoke alarm as MASTER and apply ‘Master’ label.
Treat all other alarms as SLAVE.

Use a flat-bladed screwdriver to carefully switch Master and all Slave alarms ON.
Note: Take care when inserting screwdriver.
Adding SLAVE alarms

Press MASTER Te st/Hush 3 times in 2 seconds. (Network LED B flashes blue for 30 s.)

Press SLAVE Test/Hush 3 times in 2 seconds while MASTER blue LED is On.
Network LED flashes red or green for 3 seconds.
Then, both Master and Slave Network LEDs flash green for a further 3 seconds indicating successful interconnection.
5. Repeat step 4 on all SLAVE alarms.
6. Test on one unit after MASTER network LED has turned off. Refer to Testing the smoke alarm.

Removing SLAVE alarms
Notes:

  1. Never remove the MASTER alarm.
  2. Remove slave alarm from bracket before performing the steps below.

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm - alarm
bracket 2

Note: Keep holding Test/Hush until red LED stops flashing.

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm - alarm
bracket 3

Operating the smoke alarm

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm - smoke
alarm

General information

  • Leave these instructions with the occupant, to be retained for the life of the alarm.
  • It is recommended that this smoke alarm be installed by a licenced electrician.
  • Do not remove dust cover until 24 hours after all construction has been completed. Construction dust and chemicals can cause contamination and false alarms.
  • Important: Dust cover must be removed before smoke alarm will operate correctly.

For your safety

CAUTION
EQUIPMENT INSTALLATION HAZARD

  • This product must only be used for the purpose described in these instructions and must be installed in accordance with the wiring rules and regulations in that location.
  • Ensure the product has been correctly installed and tested for safe operation.
  • Only install indoors.
  • The 755LPSMA4 is wirelessly compatible with wireless base 755RFB2.
  • The 755LPSMA4 is NOT compatible with wireless base 755RFB.
  • Check the function and wireless interconnection on each smoke alarm.
  • Test each wireless interconnected unit 1 by 1. Press and hold the Test button until second burst of 3 beeps has finished. If any unit fails to alarm, check all wireless connections.
  • Press and hold the Test/Hush button on one smoke alarm until it sounds, then check that the red LED is flashing on all interconnected smoke alarms.

Failure to follow these instructions may result in injury or equipment damage.
Operating elements

  • Network LED (wireless pairing indication: yellow/blue and green: master and slave pairing modes).
  • Red LED (low battery, alarm, test and hush indicator). The LED is located within the smoke alarm casing and is visible when On.

Choosing the installation location
NOTICE
EQUIPMENT INSTALLATION COMPLIANCE
This smoke alarm must be installed in accordance with the National Construction Code and any local state legislation requirements.
Failure to follow these instructions may result in a non-compliant installation.
Prior to installing, ensure there are no obstructions in ceiling mounting locations, such as pipes or cables.

Installing the smoke alarm

  • Only install smoke alarm indoors in a stand-alone or wireless interconnected set up (see Interconnected alarms).
  • Set up wireless interconnection before installing the alarms (see Interconnected alarms).
  • Do not remove the dust cover until you are ready to test the unit. See

Interconnecting smoke alarms
(see Interconnected alarms)
Wireless interconnection on the 755LPSMA4 smoke alarm is designed for easy installation and no wiring is required. An optional wireless base (Catalogue No. 755RFB2) can be purchased separately to wirelessly interconnect with Gen 2 and Gen 4 surface mount mains powered Clipsal smoke alarms.
Always test alarm system operation after interconnected smoke alarms are added or removed.
NOTICE
EQUIPMENT INSTALLATION HAZARD

  • Maximum of 40 interconnected smoke alarms.
  • Only Clipsal 755LPSMA4 smoke alarms and Clipsal smoke alarms connected to the 755RFB2 base are compatible for interconnection with this alarm.

Failure to follow these instructions may result in injury or equipment damage.
**Mounting the smoke alarm

Operating the smoke alarm
Testing the smoke alarm

CAUTION
DO NOT USE OPEN FLAME**
Never use an open flame of any type to test your alarm.
Failure to follow this instruction may result in injury or equipment damage.

  • Test the smoke alarm once per month to ensure proper operation.
  • Press the Test/Hush button on each alarm for three seconds until the alarm sounds. If no alarm sounds, there is a defective battery or other failure. Refer to Troubleshooting.
  • If the smoke alarm is installed in a mobile home, test weekly and before every journey.
  • Check that all interconnected smoke alarms operate during the test.

Testing interconnected smoke alarms

  • The smoke alarm will send out a wireless signal once the Test/Hush button is released. All interconnected alarms will sound for 10 seconds and flash the front red LED twice a second for 5 minutes. If this does not happen, check the wireless interconnection setup and that the distance between alarms is within the specification.
  • After the first alarm has been tested, briefly press the Test/Hush button on the next interconnected alarm to stop the flashing Red LED, then press and hold the Test/Hush button again until the alarm sounds. Repeat this on all alarms.

Silencing the smoke alarm (Hush feature)

  • When the Test/Hush button is pressed during an alarm event, the smoke alarm is not sensitive to smoke for 10 minutes, after which the alarm resumes normal operation. During this hush time, the red LED flashes once every 8 seconds.
  • To silence an unwanted alarm, press the Test/Hush button until the alarm sound stops.
  • If more than one alarm is interconnected, identify the alarm with the red flashing LED, as this will be only alarm that can be hushed. All interconnected alarms will stop sounding within 5 to 10 seconds after the initial alarm is hushed.
  • If more than one alarm has a flashing red LED and sounding, the Test/Hush button on all alarms will all need to be pressed.
  • Wait 10 minutes before performing any additional testing to avoid any abnormal alarm responses.

**Snoozing smoke alarm alerts

Low battery
When the backup battery gets low, the red LED flashes once every 40 seconds, together with a beep sound. You can snooze the low battery indication for 10 hours by pressing the Test/ Hush button for 3 seconds.
Alarm fault**
When an alarm fault is detected 1 beep will sound every 40 seconds without LED flashing. You can snooze the alarm fault indication for 10 hours by pressing the Test/Hush button for 3 seconds.

LED and sound indications

Red LED/Sound

Operating mode Red LED Sound Duration
Normal mode /Standby mode 1 flash every 40 s OFF _
ALARM MODE Local alarm 1 flash every 1 s Continuous 3 beeps every 4 s
Interconnected alarm OFF Continuous 2 beeps every 1 s _
Test mode 1 flash every 1 s 3 beeps every 4 s Until Test/Hush released
Wireless Interconnection Test 2 flashes every second Continuous 2 beeps
every 1 s 5 minutes for LED 10 seconds for alarm
Hush mode 1 fla$h every 8 s OFF 10 min
Low battery mode 1 flash every 40 s 1 beep every 40 s End of life: replace

smoke alarm
Fault mode| OFF| 1 beep every 40 s| Until fault has been cleared
SNOOZE MODE| Low battery| 1 flash 40 severy| OFF| 10 hrs
Fault| OFF| OFF| 10 hrs

Network LED

Operating mode Network LED Duration
Master alarm in pairing mode Blue, flashing 30 s max. or until pairing

successful
Slave alarm in pairing mode (first time)| Red, flashing| 3 s
Slave alarm in pairing mode (previously paired)| Green, flashing| 3 s
Master and slave alarm pairing successful| Green, flashing| 3 s
Master alarm after pairing completed| Blue, flashing| 30 s
Slave alarm pairing unsuccessful| Green, flashing| 30 s or more beyond pairing time

Troubleshooting

Problem Resolution/Action
Smoke alarm does not sound when tested 1. Make sure POWER is ON. Fit the

smoke alarm on the bracket and turn the alarm body clockwise until a click is heard.
2. Press Test/Hush button until it sounds. Do not quick press.
3. If problem persists, refer to Warranty section, and replace smoke alarm.
If out of warranty, replace with new smoke alarm.
Smoke alarm beeps and red LED flashing once every 40 seconds| Battery is in low voltage condition.
Replace the smoke alarm.
Smoke alarm beeps once without red LED flashing| 1. Clean smoke alarm. Refer to Maintenance, Repairs and Service.
2. If problem persists refer to Warranty section, and replace smoke alarm.
If out of warranty, replace with new smoke alarm.
Smoke alarm sounds unexpectedly when smoke or steam is present| 1. Identify the smoke alarm that has initiated the alarm indicated by a flashing red LED and sound warning
of three beeps every seconds.
2. Press Test/Hush button on the smoke alarm to pause the alarm. Interconnected alarms will stop sounding in 5 to 10 seconds.
3. To clean smoke alarm refer to Maintenance, Repairs and Service.
4. Move smoke alarm to a new location and test.
Nuisance/false alarm (Smoke alarm sounds without any smoke present)| 1. Identify the smoke alarm that has initiated the alarm indicated by a flashing red LED and sound warning
of three beeps every seconds.
2. Press Test/Hush button on the smoke alarm to pause the alarm. Interconnected alarms will stop sounding in 5 to 10 seconds.
3. Clean smoke alarm. Refer to Maintenance, Repairs and Service.
4. If problem persists refer to Warranty section, and replace smoke alarm. If out of warranty, replace this alarm only.

False Alarm
In the event of a false alarm in an interconnected group, it is important to identify the triggering alarm(s). These alarms may need to be cleaned, serviced or replaced if necessary.
When alarms are sounding without any smoke present:

  • Identify which smoke alarm/s are being triggered – Look for the alarm/s with sound and red LED flashing.
  • Unclip all identified smoke alarms, then all interconnected alarms will stop alarming in 1 minute.
  • Clean smoke alarms in accordance with the Maintenance, Repairs and Service section.
  • Re-install and test all the smoke alarms.

If all of the above fails, contact a licenced electrician for replacement.

Maintenance, Repairs and Service

Maintenance
It is recommended that the smoke alarm is inspected monthly to ensure it is free from dirt, dust and insects. The alarm can be vacuumed or brushed with a soft brush to remove dust, dirt or kitchen grease that has accumulated. Apply a small amount of insect surface spray to a cloth and wipe around alarm/s every 3–6 months to mitigate insect ingress.
ALWAYS TEST THE SMOKE ALARM AFTER CLEANING
Repairs and Service
NOTICE
EQUIPMENT MAINTENANCE INSTRUCTIONS

  • Test this smoke alarm regularly to ensure the unit is functional and that the battery is in good condition.
  • Replace the smoke alarm 10 years after date of manufacture.
  • Do not open the smoke alarm casing or repair the smoke alarm yourself. There are no user-serviceable parts inside.

Failure to follow these instructions may result in equipment malfunction or failure.
Disposal
As the smoke alarm does not contain any radioactive material, disposal with normal rubbish is permitted in Australia and New Zealand.
Before disposal, move the battery disconnect switch to the disconnect position. This will prevent the low battery warning beep when the battery eventually discharges.

Technical data

Battery Life 10 years
Operating Current ≤70 mA
Sensing Type Photoelectric. This alarm contains NO radioactive material.
Operating Temperature 0 °C to 45 °C
Ambient Humidity 5% to 95%
Interconnecting Wireless, 40 alarms maximum
Transmit Frequency 433.42 MHz
RF Range 140 m free air, 50 m indoor line of sight
Wireless Response Time Within 30 seconds
Horn Level 85 dB at three metres minimum
Mounting Type Ceiling and wall mount only
Approvals Activfire SAI Global RCM
Complies with AS 3786 AS/NZS 60065

** It is recommended to dispose of this device at an authorised electronic waste collection point. Professional recycling protects people and the environment against potential negative effects.
Trademarks and certifications**
Schneider Electric acknowledges that the Australian Standard Certified Product logo is a trademark of SAI Global, and that the Activfire Certified logo is a trademark of CSIRO.

CLIPSAL 755LPSMA4 Lithium Battery Powered Photoelectric Smoke Alarm - ICON
13

Warranty
We warrant this product to be free from defects in materials and workmanship for a period of 5 (five) years from the date of installation.
Customer care
If you have technical questions, please contact the Customer Care Centre in your country.

Australia
Schneider Electric (Australia) Pty Ltd
Customer Care Australia: 13 73 28
e: [email protected]
www.schneider-electric.com.au
New Zealand
Schneider Electric (NZ) Ltd
After hours service: 0800 735 4357 (NZ only)
Customer Care NZ: 0800 652 999
e: [email protected]
www.schneider-electric.com
PHA7373102_01

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CLIPSAL User Manuals

Related Manuals