Controller
Product Information
Hive Node Kits
Hive Node Kits are advanced IoT controllers designed to offer an efficient and compact solution for controlling devices through RS-232, IR, and Relay interfaces via IP. These kits are PoE-powered and specifically designed to enhance the capabilities of the Hive Touch control panel and the Hive KP8 control keypad.
Overall Features:
- HIVE-NODE-RELAY FEATURES
- HIVE-NODE-RS-232 FEATURES
- HIVE-NODE-IR FEATURES
Package Contents:
HIVE-NODE-IR
- 1 x HIVE-NODE-MINI main controller
- 1 x Tri-port cable adapter
- 3 x IR Emitters
HIVE-NODE-RELAY
- 1 x HIVE-NODE-MINI main controller
- 1 x Relay Sensor
HIVE-NODE-RS-232
- 1 x HIVE-NODE-MINI main controller
- 1 x RS-232 Cable
- 1 x Gender Bender
Panel Description
HIVE-NODE-MINI
ID | Name | Description |
---|---|---|
1 | USB Micro | Used for providing power to the device if a PoE switch is not |
available.
2| Receiver Port| 3.5mm receiver port, used to connect to HIVE-NODE-IR,
HIVE-NODE-RELAY, or HIVENODE-RS-232 devices.
3| Network| RJ45 PoE network port.
HIVE-NODE-IR
ID | Name | Description |
---|---|---|
1 | IR Ports | 3 x IR emitter ports. |
2 | 3.5mm Connector | Connects into the HIVE-NODE-MINI receiver port. |
HIVE-NODE-RELAY
ID | Name | Description |
---|---|---|
1 | Relay | 4 x Relay ports. |
2 | Contact Closure | 4 x Contact closure ports. |
3 | 3.5mm Connector | Connects into the HIVE-NODE-MINI receiver port. |
HIVE-NODE-RS-232
ID | Name | Description |
---|---|---|
1 | Speaker | 2 x Speakers for audio signal output. |
2 | 3.5mm Connector | Connects into the HIVE-NODE-MINI receiver port. |
Relay Tech Guide:
The relay & sensor cable is an input/output cable for use with the HIVE-NODE-
MINI. It provides relay outputs and sensor inputs, allowing control and
monitoring of various devices.
Configuration can be done through hardware jumpers and software API. External
devices are connected via push-release terminal blocks. The enclosure can be
mounted directly on a DIN rail for easy integration with external relays. The
relay outputs are fully configurable to operate as different standard relay
types and can control a wide range of devices. The sensor inputs can detect
contact closure, as well as AC and DC voltage.
Input and Output Connector Blocks:
The board provides terminal connector blocks for connecting external devices. These connector blocks are physically grouped as relay outputs and sensor inputs. Each distinct port within the relay outputs or sensor inputs uses 2 terminals. For example, in the figure above, Port 1 uses terminals 1 and 2, and port 2 uses terminals 3 and 4.
Introduction
OVERVIEW
Hive Node Kits are our advanced IoT controllers that offer an efficient and compact solution for controlling devices through RS-232, IR, and Relay interfaces via IP. These PoE-powered kits are designed specifically to enhance the capabilities of the Hive Touch control panel and the Hive KP8 control keypad.
OVERALL FEATURES
- Offers control over TCP/IP networks using a single Cat cable
- Equipped with IR, RS-232, and Relay accessories for diverse control
- Built-in IR Learner with a robust IR database for effective AV control
- PoE-powered for a convenient, hassle-free setup
- Web interface for easy setup
- UDP broadcasting for sensor data collection
- Designed to enhance the capabilities of Hive Touch control panel or Hive KP8 control keypad
- Scalable, supports multiple kits in a single installation
- Includes PC utilities for easy setup and testing
- Compact and DIN rail mountable for easy installation
- Made in the USA
HIVE-NODE-RELAY FEATURES
- 4 Relay outputs and 4 sensor inputs with LED indicators
- POE powered and easy installation with push/release terminals
- Flexible relay combinations and adaptable sensor modes
- Native compatibility with Hive Touch and Hive KP8
- Enhances the Hive-Node-RS-232 and/or Hive-Node-IR as part of a complete control solution
- Relay control via TCP and sensor updates via UDP
HIVE-NODE-RS-232 FEATURES
- Controls displays, projectors, switchers, and DSPs
- Includes PoE-powered Hive-Node-Mini with RS232 adapter and gender changer
- Supports RS-232, RS-422, RS-485, full and half duplex
- Configurable null modem settings and baud rate via web page or API
- Dedicated TCP IP port for serial communication
- Scalable and adaptable to unique project requirements
HIVE-NODE-IR FEATURES
- Versatile one-way device control
- Compatibility with an array of displays, projectors, and media players
- Includes PoE-powered Hive-Node-Mini, tri-port and 3 emitters
- Connects to single IR emitter or tri-port for multiple device control
- IR emitters provide blink feedback for easy troubleshooting
- Access to extensive IR device driver database
- Features IR learning capability via built-in sensor and utility
- Seamlessly integrates with Hive Touch and Hive KP8 controllers
Package Contents
HIVE-NODE-IR
- 1 x HIVE-NODE-MINI main controller
- 1 x Tri-port cable adapter
- 3 x IR Emitters
HIVE-NODE-RELAY
- 1 x HIVE-NODE-MINI main controller
- 1 x Relay Sensor
HIVE-NODE-RS-232
- 1 x HIVE-NODE-MINI main controller
- 1 x RS-232 Cable
- 1 x Gender Bender
Panel Description
HIVE-NODE-MINI
ID | Name | Description |
---|---|---|
1 | USB Micro | Used for providing power to the device if a PoE switch is not |
available.
2
| ****
Receiver Port
| 3.5mm receiver port, used to connect to HIVE-NODE-IR, HIVE-NODE-RELAY, or
HIVE- NODE-RS-232 devices
3| Network| RJ45 PoE network port
HIVE-NODE-IR
ID | Name | Description |
---|---|---|
1 | IR Ports | 3 x IR emitter ports |
2 | 3.5mm Connector | Connects into the HIVE-NODE-MINI receiver port |
HIVE-NODE-RELAY
ID | Name | Description |
---|---|---|
1 | Relay | 4 x Relay ports |
2 | Contact Closure | 4 x Contact closure ports |
3 | 3.5mm Connector | Connects into the HIVE-NODE-MINI receiver port |
HIVE-NODE-RS-232
ID | Name | Description |
---|---|---|
1 | Speaker | 2 x Speakers for audio signal output. |
2 | 3.5mm Connector | Connects into the HIVE-NODE-MINI receiver port |
Relay Tech Guide
INTRODUCTION
- The relay & sensor cable is an input/output cable for use with the HIVE-NODE-MINI. It provides relay outputs and sensor inputs which allow control and monitoring of a variety of devices. Configuration is accomplished through hardware jumpers and software API. External devices are connected via push-release terminal blocks. The enclosure can be mounted directly on a DIN rail, allowing for simple integration with external relays.
- The relay outputs are fully configurable to operate as a number of different standard relay types and are capable of controlling a wide range of devices.
- The sensor inputs are configurable to allow detection of contact closure, as well as AC and DC voltage
INPUT AND OUTPUT CONNECTOR BLOCKS
- The board provides terminal connector blocks for connecting external devices. These connector blocks are physically grouped as relay outputs, and sensor inputs. Each distinct port within the relay outputs or sensor inputs use 2 terminals. For example, in the figure above, Port 1 uses terminals 1 and 2, and port 2 uses terminals 3 and 4.
- Relay ports can be configured as individual SPST relays, but can also be logically grouped with other ports to create other common relay type configurations. Input ports are all individually configurable and support either voltage sensing or contact closure modes.
RELAY OUTPUTS
- The relay outputs can be configured via hardware jumpers and software API to operate as various common relay types. These supported relay types and associated jumper settings are shown in the following illustrations.
- Each relay configuration has a configurable default state. This allows relays to be set up as either normally open or normally closed. The above illustrations depict the relays in an open state with a default state of open.
- Single Pole, Single Throw:
- Each physical port functions as an individual relay, and each relay uses a single port. For example, Port 1 uses terminals 1 & 2, and Port 2 uses terminals 3 & 4.
- Single Pole, Double Throw:
- Two physical relay output ports are grouped such that pins 1 and 4 are connected as the common pole, with double (2) throws (positions), to terminal 3 and terminal 2.This mode is useful for applications where two separate outputs are needed, rather than simply turning a device on or off.
- Double Pole, Double Throw:
- Four ports (two relay blocks) are configured as a pair of SPDT relays. In this mode, the two SPDT relays are linked, so that both throw simultaneously.
ELECTRICAL SPECIFICATIONS
Relay Rating | Minimum Value | Maximum Value |
---|---|---|
Voltage | — | 24 Volts |
Current | — | 500mA |
SENSORS
Sensor inputs are versatile and allow for sensing contact-closure, as well as
the presence of voltages between ±3V and ±24V RMS value. Each terminal block
provides 2 input ports. Each input port on an input block can be configured
independently.
To configure a port for voltage input, disconnect all jumpers, or store
jumpers vertically in the bottom two positions of the jumper pins. In the
following figure, a block of 2 input ports is configured with both ports set
for voltage-sense. In this state the inputs are read as open (‘0’) until a
voltage is applied at which point the indicator LEDs turn on and the inputs
are read as closed (‘1’).
To configure input ports for contact closure, the jumpers should be placed vertically on the top two pins of each column of jumper pins, as shown below for the two ports. In this configuration, the state of the inputs will be closed (‘1’) until contact-closure occurs, at which point the input state will be open (‘0’).
SENSOR INPUT CHARACTERISTICS
Characteristics | Minimum Value | Maximum Value |
---|---|---|
Input Voltage AC/DC | ±3V (RMS)* | ±24V (RMS)* |
Input Current | 200µA | — |
Input Low to High Response | 1.5ms** | 3ms** |
Input High to Low Response | 110ms** | 250ms** |
Contact Closure Detection Source Current | — | 2mA |
For AC signals at low frequencies the minimum input voltage becomes a function
of frequency. The above graph depicts this relationship.
These times are for relay and sensor board hardware detection only and do not
include network and processing delays.
The Web GUI designed for the HIVE-NODE family allows for basic controls and device settings. This Web UI can be accessed through a modern browser, e.g., Chrome, Safari, Firefox, IE10+, etc.
To get access the Web UI:
- Connect the LAN port of the switcher to a local area network. Ensure there’s a DHCP server in the network so that the device can obtain a valid IP address. (If there is no DHCP server the video bar will revert to a 169.254.x.x address which you can find on the OSD. Use this to change the video bar IP to a static IP address and set your own.)
- Connect the PC to the same network as the HT-NODE.
- Input the HIVE-NODE’s IP address in the browser and press Enter, the following window pops up.
- Input the password (default password: admin) and click Login to enter the main page
MAIN PAGE
UI Element | Description |
---|---|
Network Settings | Click the icon to start the preview of the camera. |
Hive Node Cable | Selects the control cable to be used. |
Security | Security settings such as username and password. |
Advanced Settings
| Select the desired tracking mode between Off, Auto Framing, Speaker Tracking, and Presenter Tracking.
NETWORK SETTINGS
UI Element | Description |
---|---|
DHCP Enabled/Disabled | Click to enable/disable DHCP (default is set to |
DHCP)
Hostname| Set the desired name of the host
Save Changes| Click to save the changes
INFRARED CABLE
UI Element | Description |
---|---|
Emitter Type | Select the IR connection method |
Save Changes | Click to save any changes to the IR emitter selection |
SERIAL CABLE
UI Element | Description |
---|---|
Baud Rate | Set the desired baud rate: |
Flow Control (RS-232) |
Duplex (RS-485)
| Select between half and full duplex when using RS-485. Set Full for 4-signal RS-485, and
Half for 2-signal RS-485.
Parity| Set desired parity: None, Even, or Odd
Data Bits| Set the desired data bits
Stop Bits| Set the desired stop bits
Gender Changer (RS-232)
| The gender of the data cable can be changed using the included gender changer.
· True: used if the gender changer is used
· False: used if the gender changer is not used
Errors| Tracks any communication errors that may occur. Click to reset each error count.
RELAY/SENSOR
UI Element | Description |
---|
Relay Type
| In Presenter Tracking mode the camera frames the location of the presenter. This is typically used for a single presenter.
Note: there are no adjustments for smooth or speed of the framing in this mode.
Jumper Settings| Mirror flips the camera in the mirrored direction.
Current State
| If there is flicker in the camera, typically caused by fluorescent light bulbs in the room, change the set frequency to the other one. (Options are 50Hz or 60Hz)
Sensors
| Off decreases the quality of the camera to ensure laptop compatibility; On increases the quality to HD.
Save Changes
| Adjusts wide dynamic range to improve the camera’s image quality under high-contrast lighting conditions.
SECURITY
UI Element | Description |
---|---|
User Name | Change the user name (default is admin) |
Password | Change the password (default is admin) |
Web Lock | Click to enable/disable web lock |
API Lock | Click to enable/disable API lock |
System Lock | Click to enable/disable System Lock |
Save Changes | Click to save any changes made to the security settings |
ADVANCED
UI Element | Description |
---|---|
Reboot | Click to reboot the HIVE-NODE-MINI |
Factory Reset | Click to restore the HIVE-NODE-MINI to the original |
factory settings
Utility Applications
There are four different utility applications.
NODE CONVERT
This utility is used to convert between IR codes and Hex codes. This is an
executable file and does not require installation.
UI Element | Description |
---|---|
Input | Enter the command you wish to have converted |
Convert From/To | Use the drop-down to select the desired command to be |
converted to.
Convert| Click on “Convert” to convert the command.
NODE HELP
This utility is used to locate and configure HIVE-NODE-MINI devices on the
network and is necessary to update the firmware. This is an executable file
and does not require installation. When this utility is used it sends out
multicast beacons and displays every MAC ID and IP Address within one minute.
UI Element | Description |
---|---|
Detected Units | Displays all detected HIVE-HIVE-NODE-MINI devices on the |
network
Auto refresh / Refresh
| Click to checkbox to enable auto refresh. With this enabled the NodeHelp utility will constantly search for new HIVE-NODE-MINI devices. If unchecked, click the “Refresh” button to refresh the list manually.
NODE LEARN
This utility is used to capture IR commands from different devices. This is an
executable file and does not require installation.
UI Element | Description |
---|---|
Connection | Select the desired HIVE-NODE-MINI and click connect. |
Capture Options | Set the desired capture options. |
Format | Select the desired output format of the learned IR command |
Save | Save the learned command to the desired file location. |
NODE TEST
This utility is used to send literal strings, individual hex bytes, or a
mixture of both to devices connected to HIVE-NODE-MINI. This utility contains
two receive windows, one printing ASCII, and the other printing the hex values
of each character received in a sixteen-byte hex dump format. This is an
executable file and does not require installation.
UI Element | Description |
---|
Communications
| Select the desired communication string along with the HIVE-NODE-MINI’s IP address and
connect to the device.
Command String| Enter the command string to be tested and hit Send
Responses| Responses to the command will be shown in these windows
Specifications
HIVE-NODE-MINI
Interface| 1 x RJ45, 1 x USB Micro, 1 x 3.5mm Connector
Setup & Configuration| Integrated web server for easy configuration and HTTP
control
Network Connection| DHCP (default) & Static, 10/100 Mb Ethernet protocol
LED Indicators| Power to indicate activity and status
Control APIs
| TCP
Ÿ ASCII textual commands
Ÿ Comma delimited, carriage return terminated
HTTP
Ÿ Web-based control using HTTP commands with JSON payload data
Dimensions (L x W x H)| 65.5mm x 30.99mm x 20.83mm (2.58” x 1.22” x 0.82”)
Certifications| FCC (Part 15, Class B), C-tick, RoHS compliant
Infrared
IR Output| 3.5mm connector, from 20 to 500 kHz
IR Tri-Port| Support for emitter-emitter-emitter or emitter-emitter-blaster
Relay
Relay Outputs
| Ÿ 4 Integrated SPST relays with transient voltage suppression and easy push release terminal blocks
Ÿ 24V AC/DC or 500mA N.O. contact relays
Relay Configurations
| Ÿ Single Pole Single Throw (SPSP)
Ÿ Single Pole Double Throw (SPDT)
Ÿ Double Pole Double Throw (DPDT)
Sensor Inputs
| Ÿ 4 configurable inputs
Ÿ Voltage or contact closure sense modes
Voltage Sense Mode| Sense AC/DC voltages ±3V (RMS) to ±24V (RMS)
Contact Closure Mode| Sense contact closure from input from devices or
feedback from external relays
Cable/Connector
| Ÿ 3.5mm four conductor jack to HIVE-NODE-MINI
Ÿ 4 easy push four terminal blocks for relay and sensor connections
Ÿ 16 hardware jumpers included
Ÿ 4.5 ft (1.5m) cable
Dimensions (L x W x H)| 82.3mm x 50.8mm x 22.86mm (3.24” x 2” x 0.9”)
Serial
Serial Outputs
| RS-232
Ÿ Full support for Tx, Rx, CTS, RTS, DTR, and DTS signals
Ÿ Bi-directional communication with hardware handshaking
| RS-232 Mini Jack
Ÿ Full support for Tx, and Rx signals
Ÿ Bi-directional communication with hardware handshaking
RS-485
Ÿ Four wire (full duplex) and Two wire (half duplex) capable
---|---
Serial Configurations
| Ÿ Baud Rate: 300 baud to 115200 baud
Ÿ Parity: Even, Odd, or None
Ÿ Stop Bits: 1 or 2
RS-232
Ÿ Flow Control: Enable hardware RTS/CTS flow control.
Ÿ Gender: Allows configuration of cable gender. Allows for null modem and straight through cable creation.
RS-232 Mini Jack
Ÿ Gender: Allows for null modem and straight through cable creation.
RS-485
Ÿ Duplex: full duplex or half duplex
Ÿ RS-422 compatible
Cable/Connector
| Ÿ 3.5mm four conductor jack to HIVE-NODE-MINI
RS-232
Ÿ Male DB9 connector with locking screws
Ÿ Includes gender changer
Ÿ 5ft (1.5m) cable
RS-232 Mini Jack
Ÿ Male 3.5mm mini jack stereo connector
Ÿ 6.5ft (2m) cable
RS-485
Ÿ 5-pin screw terminal block
Ÿ Connector at 90° angle for easy fit
Ÿ 5ft (1.5m) cable
Dimensions (H x L x W)| 55.9mm x 32.5mm x 15.2mm (2.2” x 1.28” x 0.6”)
© Copyright 2022. Hall Technologies