SUSSEX RWBHS150RH Wall Basin Hostess System Instruction Manual

June 12, 2024
SUSSEX

SUSSEX RWBHS150RH Wall Basin Hostess System Instruction Manual
SUSSEX RWBHS150RH Wall Basin Hostess System

Product code

  • RWBHS150RH Wall basin hostess syst 150mm
  • RWBHS200RH Wall basin hostess syst 200mm
  • RWBHS250RH Wall basin hostess syst 250mm
  • RWBHS150RH-V Wall basin hostess syst 150mm – Vertex
  • RWBHS200RH-V Wall basin hostess syst 200mm – Vertex
  • RWBHS250RH-V Wall basin hostess syst 250mm – Vertex

Rough in plumbing (MASTERFIT) mounting guide

Rough in plumbing

  • The Masterfit will be supplied with the Spindles pre-installed.
  • Prepare a nogging and secure 28-32mm back from the front Using the screws (x4) of the stud (See Fig.1)
  • The Masterfit (in-wall) will be marked “This side Up” to Ensure the Masterfit is indicate orientation.
  • Using the screws (x4) provided, mount the Masterfit (in-wall) to the Nogging.
  • Ensure the Masterfit is level and square to the Wall Studs.

Pipe connections

  • The Masterfit is supplied with coloured thread Caps to protect and identify the Hot and Cold inlet connections.
  • All lines must be free from any dirt and debris before connecting to the Masterfit. Flush all water feed lines.
  • Connect Hot and Cold lines to the corresponding 1/2” BSP ports of the Masterfit. (See Fig.1A)
  • Do not remove or disturb any factory fitted Pressure Plugs or Fixings.
  • Once all water connections are made, use the “Spindle Handle Adapter” and check Hot/Cold water operation.
  • Check all fittings and connections for leaks.
  • Store the Dress Kit in a safe place until required for Fit off.

Fitting off

Fitting off

  • Seal the wall around the Locking Sleeve and immediately fit the Dress Ring.
  • Fit the Handle Body, the Handle Body must be fully engaged onto the Spindle; note the Set Screw contact point. (See Fig.1B)
  • Secure the Handle body by tightening the Set screw using the 2mm Allen key provided. (Tighten well)
  • After completing the installation, establish water supply, check function of Tapware and ensure no water leaks.

Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003 Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c
Copyright © Sussex Taps.

Company Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>