Introduction
This is A professional digital anemometer with stable performance, safety and reliability. It is widely used in wind energy, meteorology, industry, agriculture, hydrology and water conservancy, environmental protection, highways, airports and ports, etc.
Display screen
symbols | description | symbols | description |
---|---|---|---|
H | Data hold | m/s | meter per second |
MAX | Maximum value | Km/h | kilometers per hour |
MIN | Minimum value | mil/h | Miles per hour |
AVG | Average value | ft/m | Foot per minute |
°C | Celsius | ft/s | Feet per sec |
--- | --- | --- | --- |
°F | Fahrenheit | knots | nautical miles per hour |
%RH | Humidity unit | Low battery | |
Wind speed | |||
simulation bar | Automatic shutdown |
Considerations
- Do not touch the fan blade with force.
- Do not store or operate the instrument in areas with high temperature or humidity.
- In use, do not let the strong light directly shine on the fan, in order to avoid measurement errors.
- Avoid violent vibration.
- Remove the battery before storing the instrument for a long time.
Operation
wind speed measurement:
- Press me button to turn on the power.
- Hold the anemometer and let the fan plane of the anemometer align vertically with the wind direction of the airflow for measurement.
- The display will show the wind speed, wind temperature and wind humidity at the same time.
Data hold:
To freeze a displayed reading, press the button(<1 Sec.). The “H” icon will
appear and the most recent reading will appear in the display. Press the
button(<1 Sec.) to exit the mode and return to normal mode.
Backlight on or off:
Press the button and hold it for more than 2 seconds to enable or disable the
backlight function.
MAX/MIN/AVG function:
Press the key (:51 Sec.) to turn on the maximum function, and then press the
key to cycle through the maximum, minimum and average values. Long the key
press (>1 Sec.) returns to normal measurement function.
Temperature unit selection:
Press the key to select the temperature unit.
Wind speed unit selection:
Press the key to select the desired wind speed unit (m/s, km/h, mill/h, ft/m,
ft/s, knots).
Auto shutdown function.
When the power is turned on, the automatic shutdown function is turned on by
default. No operation within 10 minutes will automatically shut down.
If you need to cancel the auto-off function, press and hold the key before
turning on the meter, then press the key to turn on the power, and then
release the key after the meter is turned on, the auto-off function
will be canceled.
To restore the auto-off function, turn on the power again to restore the auto-
off function. When the meter turns on the auto-off function, the display will
show the symbol; when the auto-off function is canceled, it will not show.
Specifications
Display | LCD, Max display 9999 |
---|---|
Air velocity | 0.70 – 30.00 mis |
Sampling rate | One reading per 0.5 Sec. |
Sensor | Air velocity flow sensor: angled vane arms with bearing |
Max Min Avg | minimum, maximum, average measurement |
Data hold | Freeze reading |
Operating conditions | Temperature:0-40°C, |
Humidity:<80%RH Altitude :<2000m
Storage conditions| Temperature:-1050°C,
Humidity:<80%RH
Auto power off| 10 minutes
Power| 3 x 1.5VAAA(LR03) batteries
Accuracy Specifications
The accuracy applies within one year after the calibration.
Reference condition: the environment temperature 18°C to 28°C, the relative
humidity is no more than 80%
Air velocity measurements | Range | Resolution |
---|---|---|
m/s | 0.70 — 30.00 | 0.01 |
km/h | 2.50-108.0 | 0.01-0.1 |
ft/s | 2.30 — 98.50 | 0.01 |
ft/m | 137.0— 5900 | 0.1-1 |
knots | 1.30 — 58.30 | 0.01 |
mil/h | 1.50 — 67.10 | 0.01 |
--- | --- | --- |
Accuracy of air velocity | < 1.00m/s: t0.7 m/s |
1.00-30.00 m/s: ±(2.0%+ 0.5m/s)
Range of temperature| -20.0°C — 60.0°C (-4.0°F-140.0°F)
Resolution of temperature| 0.0 — 45.0°C: ±1.0°C
others: ±1.5°C
Range of humidity| 0.0% —99.9%RH
Resolution of humidity| 20%— 80% RH: ±5.0%RH
others: ±6.0%RH
Maintenance
Battery replacement
When the meter shows the symbol” “, please replace the battery in time.
- Unscrew the battery cover, and then open the battery cover.
- Remove the batteries from the battery compartment.
- Install the new battery correctly according to the positive and negative marks on the bottom of the battery compartment.
- Reinstall the battery cover and fasten the screws to secure it.
Cleaning
caution
To avoid damaging the case, do not use corrosive agents or solvents to
clean the instrument.
Wipe the shell regularly with detergent or a damp cloth and detergent.
INSTRUMENTS
Documents / Resources
| HTC
INSTRUMENT AVM-03 Digital
Anemometer
[pdf] User Manual
HT605, AVM-03 Digital Anemometer, AVM-03, Digital Anemometer, Anemometer
---|---