CROWN EPX-3 Electric Counter Steamer Instruction Manual

June 4, 2024
CROWN

Job: __ Item# _____

Electric Counter Steamer
Manual Fill, Manual Drain

EPX-3

Models:
EPX-3
EPX-5

OPERATION SHALL BE BY:

Electrically heated, boiler free steam generation rated at:

9.0 kW for Model EPX-3
15.0 kW for Model EPX-5

The steam boiler shall be equipped for operation on:
208 VAC, 3 Phase, 50/60 Hz
240 VAC, 3 Phase, 50/60 Hz

* UNIT SHALL BE FIELD CONVERTIBLE TO SINGLE PHASE AND ALSO CONFIGURABLE TO 2/3 RATING.
6.0 kW for Model EPX-3
10.0 kW for Model EPX-5

STANDARD FEATURES:

  • 304 stainless steel exterior
  • 316 stainless steel cooking chamber with coved corners
  • Heavy gauge stainless steel door with full perimeter gasket
  • Positive lock and seal mechanism with spring release door
  • Illuminated cooking/off/constant steam power switch
  • Ready indicator light
  • Cooking indicator light
  • Add water indicator light with audible alarm
  • 60 minute electromechanical timer with end-of-cycle audible alarm
  • 4″ adjustable legs
  • Removable stainless steel pan supports
  • Removable steam diffuser plate helps prevent objects from falling into water reservoir
  • Selectable timed or constant steam cooking mode
  • Electromechanical controls
  • 16 oz. QuickClean treatment included

OPTIONS & ACCESSORIES AT ADDITIONAL COST

220 VAC, 3 Phase, 50/60 Hz
380 VAC, 3 phase, 50/60 Hz
415 VAC, 3 phase, 50/60 Hz
480 VAC, 3 phase, 50/60 Hz
600 VAC, 3 phase, 50/60 Hz (EPX-3 only)
380/220 VAC, 3 Phase, 50/60 Hz 4 wire
415/240 VAC, 3 Phase, 50/60 Hz wire
Correctional package
120-minute timer
28″ high single unit stand
Double unit stacking stands available (see stacked spec sheet for details)
Caster kit for single unit stand
Drain hose kit

STANDARD CONSTRUCTION SPECIFICATIONS

Shall be a Crown model EPX-3 (3 pan) or EPX-5 (5 pan) countertop, boiler free convection steamer, c-CSA-us and NSF certified.
Unit shall be connectionless, no plumbing required.
Unit shall be constructed of satin finish 304 stainless steel with a one-piece welded 316 stainless steel cooking chamber with coved corners.
The door shall have a removable inner liner of stainless steel with full perimeter gasket seal, an outer liner of one-piece all welded stainless steel, and a positive lock and seal mechanism with spring release.
The steamer shall have removable stainless steel pan supports and steam diffuser plate.
The control housing shall be constructed of stainless steel with a full access removable panel.
The controls shall include an illuminated timed cooking/off/constant steam switch, a ready indicator light, cooking indicator light, 60 minute electric timer with audible alarm that signals the end of the cook cycle, and a low water indictor light with audible alarm.
A door interlock switch shall interrupt steam generation when the door is open and shall be reactivated when the door is closed. Provide options and accessories as indicated.

NOTE: DRAIN PAN PROVIDED BY OTHERS.

Approval Notes:




SERVICE CONNECTIONS ­

ELECTRICAL CONNECTION: Ø 1 1/8″ (29 mm) hole for electrical connection. Rating to be specified on data plate.
­ DRAIN: 1/2″ NPT

ELECTRICAL CHARACTERISTICS

MODEL KW AMPS/PHASE
208V 220V 240V
1 PH 3PH 1 PH
3PH 3PH 3PH
EPX-3 9
6 43.3
28.9 25.0
N/A 40.9
27.3 23.6
N/A 37.5
25.0 21.7
N/A 13.7
N/A 12.5
N/A 10.8
N/A 8.7

N/A
EPX-5| 15
10| 72.1
48.1| 41.6
N/A| 68.2
45.5| 39.4
N/A| 62.5
41.7| 36.0
N/A| 22.8
N/A| 20.9
N/A| 18.0
N/A| 14.4
N/A

COMPARTMENT PAN CAPACITY, WEIGHT AND CLEARANCE

MODEL| PAN
DEPTH| INCHES| 1| 3.| 4| 6| SHIPPING WEIGHT| MINIMUM CLEARAN
---|---|---|---|---|---|---|---|---
MM| 25| 64| 102| 152
EPX3| Total Quantity of Pans| 6| 3| 2| 1| 161 lbs. [73 kg]| SIDES| 0
EPX-5| 10| 5| 3| 2| 183 lbs. [83 kg]| BACK| 3

WATER QUALITY STATEMENT

Water is the essential ingredient in steam equipment, water quality is the major factor affecting the performance of your appliance. Crown Steam Group offers a Comprehensive Water Treatment System which exceeds our minimum water requirements. Proof of installation and proper cartridges replacement is required for warranty coverage. Water supply to Crown Steam Group steamers must be within these guidelines.

Total dissolved solids…………………..Less than 60 PPM
Total alkalinity …………………………………. Less than 20 PPM
Silica………………………………………………. Less than 13 PPM
Chlorine ……………………….Less than 1.5 PPM pH
Factor …………………….6.8 – 7.3

Water which does not meet these standards should be treated with the installation of Middleby’s Water Treatment System. Call 919-762-1000 if you have questions concerning your water meeting these parameters. *Failure or malfunction of this appliance due to poor water quality is not covered under warranty. Reference www.crownsteamgroup.com for complete warranty details and instructions.

DISCLAIMER

Terry System Cartridge Changes / Installation ­ “2-3 gallons of water MUST be purged at each cartridge change or new installation prior to water supply being fed to the steamer. Failure to do so can result in component damage within the steamer which is not covered under warranty. For additional guidance on proper installation, refer to install documentation provided with each Terry System and Replacement Cartridge Set.”

INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.

Form EPX Rev 1 (June/2021)
70 Oakdale Road, Toronto ON, Canada M3N IV9
919-762-1000 www.crownsteamgroup.com

Printed in USA Date:____

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals