ZEISS HFA3 Humphrey Field Analyzer User Manual

June 12, 2024
Zeiss

ZEISS HFA3 Humphrey Field Analyzer

Humphrey Field Analyzer 3 from ZEISS
Reduce testing time and increase insight into glaucoma.

Product Information

The ZEISS Humphrey Field Analyzer 3 (HFA3) is an innovative device designed to advance clinical efficiency in the diagnosis and management of glaucoma. It is a reliable tool that thousands of practices depend on for essential diagnoses.

The HFA3 features SITA Faster Testing, which optimizes test results for both the healthcare professional and the patient. SITA adapts to patient responses, making optimal use of the information contained in the patient’s responses and continuously refining the measurements. This ensures accurate and insightful analysis of the  patient’s visual field.

The HFA3 offers various testing strategies, including SITA Faster 24-2C, SITA Fast 24-2, and SITA Standard 24-2. The new SITA Faster 24-2C test adds 10 test points to the 24-2 pattern, specifically examining areas along physiologically relevant nerve fiber bundles known to be susceptible to glaucomatous defects.

The HFA3 also includes STATPACTM statistical software, which compares test results to proprietary age normative and glaucoma databases. This allows for expert analysis of changes in the patient’s visual field over time.

Product Usage Instructions

  1. Position the patient comfortably in front of the Humphrey Field Analyzer 3.
  2. Select the appropriate testing strategy based on the patient’s condition and requirements. Options include SITA Faster 24-2C, SITA Fast 24-2, and SITA Standard 24-2.
  3. Explain the test procedure to the patient, ensuring they understand the importance of accurate and reliable responses.
  4. Initiate the test and allow the patient to respond to the presented stimuli.
  5. During threshold testing, the HFA3 will adapt to the patient’s responses, continuously refining measurements for optimal accuracy.
  6. Monitor the test progress and ensure the patient maintains focus and attention throughout the duration of the test.
  7. Once the test is complete, the HFA3 will generate visual field test results.
  8. Utilize the STATPACTM statistical software to analyze changes in the patient’s visual field over time, comparing results to age normative and glaucoma databases.
  9. Based on the analysis, provide expert insights and recommendations for the patient’s diagnosis and management of glaucoma.

Reduce testing time and increase insight into glaucoma.
ZEISS Humphrey Field Analyzer 3

The ZEISS HFA3 featuring SITA Faster Testing
The Humphrey® Field Analyzer 3 (HFA3) combines everything you value in a Humphrey with expanded testing options and reduced patient test times.

Optimize results for you and your patient.

  • Expand testing options. Optimize your patient management with new SITA™ Faster 24-2 and 24-2C tests.
  • Identify progression. Guided Progression Analysis™ (GPA™) helps determine if visual field loss is progressing (where and how fast) to help augment treatment.
  • Streamline workflow. Reduce set-up time and provide best test results with the Liquid Trial Lens™ and automated eye alignment.
  • Interact with results. Access HFA3 results and the entire patient test history as well as change baselines on the fly.
  • Synchronize data for complete patient history. Test patients at any HFA3 or HFAII-i, and generate reports with complete test history.
  • See the whole picture. HFA is the cornerstone of the Integrated Diagnostic Imaging platform for glaucoma
    that provides a new level of information for optimal patient management based on visual field function and corresponding OCT structure data.

Everything you depend on, only from a Humphrey

The innovations in HFA3 add to the reliable standard that thousands of practices already depend on for essential diagnoses.

SITA “adapts” to patient responses
HFA SITA™ Strategies are the standard of care in visual field testing. SITA makes optimal use of the information contained in the patient’s responses, looks at the complete pattern of patient responses while thresholding, and continuously refines the measurements.

Threshold testing is faster than ever with SITA Faster 24-2

ZEISS-HFA3-Humphrey-Field-Analyzer-2

SITA Faster 24-2 improves clinical workflow and patient satisfaction with the fastest test time in HFA threshold testing. Approximately 50% faster than SITA Standard, SITA Faster 24-2 is also about 30% quicker than SITA Fast, yet offers the same reproducibility.

Obtain more information in central visual field

The new SITA Faster 24-2C test adds 10 test points to the 24-2 pattern. They were selected to examine areas along physiologically relevant nerve fiber bundles known to be susceptible to glaucomatous defects.1-6

Expert analysis of visual field test results

STATPAC™ statistical software compares results to proprietary age normative and glaucoma databases for analyzing changes in the patient’s visual field over time.

  1. Heijl A1, Patella VM2, Chong LX3, Iwase A4, Leung CK5, Tuulonen A6, Lee GC2, Callan T2, Bengtsson B7. A new SITA perimetric threshold testing algorithm; construction and a multi-center clinical study. Am J Ophthalmol. 2018 Oct 15. pii: S0002-9394(18)30592-0. doi: 10.1016/j.ajo.2018.10.010. [Epub ahead of print]
  2. Donald C. Hood,a,b,*,1 Ali S. Raza,a,c,1 Carlos Gustavo V. de Moraes,d,e,1 Jeffrey M. Liebmann,d,e,1 and Robert Ritchd,f,1. Glaucomatous damage of the macula. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3529818/
  3. Ilana Traynis, B.S.,1,2 Carlos G. De Moraes, M.D.,4,5 Ali S. Raza, B.A.,1 Jeffrey M. Liebmann, M.D.,4,5 Robert Ritch, M.D.,4,6 and Donald C. Hood, Ph.D.1,3. The Prevalence and Nature of Early Glaucomatous Defects in the Central 10° of the Visual Field. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4204644/
  4. De Moraes CG1, Hood DC2, Thenappan A3, Girkin CA4, Medeiros FA5, Weinreb RN5, Zangwill LM5, Liebmann JM6. Visual Fields Miss Central Defects Shown on 10-2 Tests in Glaucoma Suspects, Ocular Hypertensives, and Early Glaucoma. Ophthalmology. 2017 Oct;12 4(10):1449-1456. doi: 10.1016/j.ophtha.2017.04.021. Epub 2017 May 24. 24-2. https://www.ncbi.nlm.nih.gov/pubmed/28551166 Invest Ophthalmol Vis Sci. 2014 Feb 3;55(2):632-49. doi: 10.1167/iovs.13-13130.
  5. Hood DC1, Slobodnick A, Raza AS, de Moraes CG, Teng CC, Ritch R. Early glaucoma involves both deep local, and shallow widespread, retinal nerve fiber damage of the macular region. https://www.ncbi.nlm.nih.gov/pubmed/24370831
  6. Donald C. Hood,1,2 Matthew Nguyen,1 Alyssa C. Ehrlich,1 Ali S. Raza,1,3 Ieva Sliesoraityte,4,5 Carlos G. De Moraes,2 Robert Ritch,6,7 andUlrich Schiefer4,8. A Test of a Model of Glaucomatous Damage of the Macula With High-Density Perimetry: Implications for the Locations of Visual Field Test Points. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4064621/

ZEISS-HFA3-Humphrey-Field-Analyzer-5

Inform your decision-making with GPA

GPA™ (Guided Progression Analysis) is designed to help you identify where, and how fast, defects are progressing. GPA allows transition to new SITA tests while maintaining analysis of the complete patient history.

Identify consecutive change at each test point

Progression Analysis Probability Plot is designed to identify statistically significant progression events in consecutive visits at individual test points. GPA Alert displays a plain language message about the likelihood of disease progression.

Visualize rate of progression

Visual Field Index™ (VFI) is a measure of the patient’s overall visual function as compared to an age-adjusted normal population. VFI trend analysis helps differentiate rapid versus slow progressing visual field loss.

HFA3 makes visual field testing faster and easier than ever

Simple to operate

ZEISS-HFA3-Humphrey-Field-Analyzer-8

  1. Liquid Trial Lens technology reduces setup time by automatically loading each patient’s refractive correction from the previous exam.
  2. Automated eye alignment centers the patient’s eye to the trial lens and adjusts to the patient during the test to provide fast setup and best results.
  3. With the intuitive SmartTouch interface you simply select the patient’s name and press start to begin testing.

Enhancing workflow from patient testing to report review

New Review Software delivers comprehensive analysis and improves digital workflow.

  • Quickly access HFA reports in every exam lane.
  • Modify reports on-the-fly to include and exclude tests, reset baselines and follow up on tests.
  • Simple visual reports foster clear patient communication, which may help improve compliance.

Data Synchronization automatically updates and integrates patient tests from any connected HFA3. HFA-IIi contributes tests to HFA3, enabling you to use existing HFA-IIi devices to supplement testing capacity.

Technical data Specifications

Choose the HFA3 that’s right for you

ZEISS-HFA3-Humphrey-Field-Analyzer-13

Test specifications

Maximum temporal range (degrees) 90 30 30
Stimulus duration 200 ms 300 ms 200-400 ms
Visual field testing distance 30 cm Infinity Infinity
Background illumination 31.5 ASB 100 cd/m2 100 cd/m2

Threshold test library

N-30
C-20
24-2, 30-2, 10-2, Macula
60-4, Nasal step

Threshold test strategies

SITA Standard, SITA Fast, SITA Faster, Full Threshold, FastPac| •| •| •| •| |
---|---|---|---|---|---|---
SITA-SWAP| | | •| •| |
MOBS| | | | | •| •
ZEST| | | | | •|

Suprathreshold test library

C40, C76, C80| •| •| •| •| |
---|---|---|---|---|---|---
C64, C-Armaly| •| •| •| •| |
C-20| | | | | | •
N-30| | | | | •| •
24-2| | | | | •|
Peripheral test patterns| •| •| •| •| |

Suprathreshold test modes

Age corrected
Threshold related, Single intensity

Specialty test library

Social Security Disability, monocular, binocular| •| •| •| •| |
---|---|---|---|---|---|---
Esterman monocular, binocular, superior 36, 64| •| •| •| •| |
Kinetic testing| | •| •| •| |
Custom Kinetic testing| | •| •| •| |
Custom Static testing| •| •| •| •| |

Fixation control

Heijl-Krakau blind spot monitor
Video eye monitor
Gaze tracking
Head tracking
Vertex monitoring

Operator interface

| Touchscreen LCD| LCD| LCD
---|---|---|---
| •| •| •| •| | •

Stimulus

Frequency doubling
White-on-white
Red- or blue-on-white
Blue-on-yellow (SWAP)

General testing features

Stimulus sizes Goldmann I-V 10° 2°, 5°, 10°
Foveal threshold testing
Automatic pupil measurement
Liquid Trial Lens (AutoTLC)
RelEYE eye review

Test storage

ZEISS-HFA3-Humphrey-Field-Analyzer-14

Software features

Single Field Analysis (SFA)| •| •| •| •| |
---|---|---|---|---|---|---
Glaucoma Hemifield Test (GHT)| •| •| •| •| | •
Visual Field Index (VFI)| •| •| •| •| |
Guided Progression Analysis (GPA)| •| •| •| •| |
Mixed GPA| •| •| •| •| |
Serial field overview| •| •| •| •| | •
Networking| •| •| •| •| | •
FORUM Connectivity| •| •| •| •| | •
DICOM Connectivity| •| •       •| •| | •

Printer

Thermal printer| | | | | •|
---|---|---|---|---|---|---
Native generic PCL 3, PCL 5 and postscript printer support for local, shared and networked printers| | | | | | •
Native postscript printer support for network capable printers| Optional| |

Data storage, retrieval and analysis

Hard drive 500 GB 250 GB
USB
CD-R/W drive

Dimensions

Height 23″ (58 cm) 17″ (43 cm) 17″ (43 cm)
Width 20″ (51 cm) 10″ (25 cm) 12.2″ (31 cm)
Depth 18″ (46 cm) 19″ (48 cm) 33.5″ (85 cm)
Weight 63 lbs (28.7 kg) 19 lbs (8.6 kg) 37.5 lbs (17.4 kg)

Electrical requirements

ZEISS-HFA3-Humphrey-Field-Analyzer-15

Standards

ZEISS-HFA3-Humphrey-Field-Analyzer-16

See the whole picture

Integrated Diagnostics Imaging platform for Glaucoma
Glaucoma management is evolving to require a new diagnostic environment to support your clinical assessment when and where you need it.
The Integrated Diagnostics Imaging platform delivers information critical to understanding and managing your patients by offering connection to multi- modality data sets. The combined analysis of HFA3 and CIRRUS™ HD-OCT lets you observe, identify and evaluate structural and functional changes earlier, for better glaucoma management.

ZEISS-HFA3-Humphrey-Field-Analyzer-11

ZEISS Integrated Diagnostic Imaging – Glaucoma

en-OUS_31_020_0016I Printed in Germany. CZ-VIII/2021 International edition: Only for sale in selected countries.
The contents of the brochure may differ from the current status of approval of the product or service offering in your country. Please contact our regional representatives for more information. Subject to changes in design and scope of delivery and due to ongoing technical development. Humphrey, HFA, Liquid Trial lens, CIRRUS, Guided Progression Analysis, GPA, SITA, Visual Field Index, VFI, STATPAC, Humphrey FDT, and Humphrey Matrix are either trademarks or registered trademarks of Carl Zeiss Meditec AG or other companies of the ZEISS Group in Germany and/or other countries.
© Carl Zeiss Meditec Inc., 2021. All rights reserved.
0297

Humphrey Field Analyzer 3
Carl Zeiss Meditec, Inc. 5300 Central Parkway Dublin, CA 94568

USA
www.zeiss.com/HFA3 www.zeiss.com/med/contacts

Carl Zeiss Meditec AG
Goeschwitzer Str. 51-52 07745 Jena

Germany
www.zeiss.com/med/contacts

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals