SUSSEX RMOS150RH Wall Bath Mixer System Dress Kit Installation Guide
- June 12, 2024
- SUSSEX
Table of Contents
SUSSEX RMOS150RH Wall Bath Mixer System Dress Kit
Product Information
The Circa Wall Bath Mixer System is a versatile and stylish tapware solution for your bathroom. It comes with a Dress Kit thatincludes various components for installation and usage. The product is available in three different sizes: 150mm, 200mm, and 250mm. Additionally, there is a Vertex variant available for each size, which offers a unique design.
The product code for each variant is as follows:
- RMOS150RH – Wall bath mixer system 150mm
- RMOS200RH – Wall bath mixer system 200mm
- RMOS250RH – Wall bath mixer system 250mm
- RMOS150RH-V – Wall bath mixer system 150mm – Vertex
- RMOS200RH-V – Wall bath mixer system 200mm – Vertex
- RMOS250RH-V – Wall bath mixer system 250mm – Vertex
Product Usage Instructions
Installation of Mixer Dress Kit
- Remove the protective cover from the mixer.
- Apply silicone sealant around the wall surface and outlet threads to ensure a watertight seal.
- Fit the Mixer Dress Ring onto the mixer cartridge lever.
- Attach the Handle Body onto the Mixer Cartridge Lever, ensuring full engagement.
- Tighten the set screw using the provided Allen Key to secure the Handle Body in place.
Outlet Fit Off
- Apply sealing tape (Teflon) to the male thread of the outlet.
- Place the Dress Ring and Dress Flange over the prepared male thread.
- Fit and align the Outlet onto the male thread.
- Operate the mixer(s) to check the flow of both hot and cold water from the Outlet to complete the installation.
After installation, make sure to check all fittings and fixtures for any water leaks.
Rough-In Plumbing
Prior to installing the Circa Wall Bath Mixer System, calculate the finished wall thickness. The maximum thickness allowed is 30mm. If the wall thickness exceeds 30mm, contact the manufacturer for further options.
- Prepare a Nogging to be fixed parallel between the wall studs.
- The Nogging should be fitted in a way that the base of the Masterfit is 30-32mm back from the Stud Face.
- Mount the Masterfit onto the Nogging using the provided screws (x4). Ensure that it is level and square.
Pipe Connections
During on-site high-pressure line testing, ensure that the mixer is in the closed position. Do not open the mixer when the maximum stated water pressure is exceeded. After testing, do not relieve any high pressure by opening the mixer. Exposing the internals of the Mixer Cartridge to higher than specified water pressures will void the manufacturer’s warranty.
Note: Tapware installation should be performed by a licensed plumber in accordance with AS/NZS 3500:2003. The recommended working water pressure is 300-500 kpa, and the maximum water temperature is 65 deg.c.
For more information, visit sussextaps.com.au
Wall bath mixer system Dress kit
Product code
- RMOS150RH Wall bath mixer system 150mm
- RMOS200RH Wall bath mixer system 200mm
- RMOS250RH Wall bath mixer system 250mm
- RMOS150RH-V Wall bath mixer system 150mm – Vertex
- RMOS200RH-V Wall bath mixer system 200mm – Vertex
- RMOS250RH-V Wall bath mixer system 250mm – Vertex
Mixer dress kit
- Remove Mixer protective cover.
- Using silicone, seal the wall sur face around the Mixer and
- Outlet threads.
- Ft the Mixer Dress Ring.
- Fit the Handle Body onto the Mixer Cartridge Lever and ensure full engagement.
- Secure the Handle Body by tightening the Set screw using the
- Allen Key provided (tighten well)
Outlet fit off
- Apply sealing tape (Teflon) to male thread.
- Place Dress Ring and Dress Flange over prepared male thread.
- Fit and align the Outlet.
- To complete installation, operate the Mixer(s) checking the flow of both hot and cold water from the Outlet.
Check all fittings and fixtures for water leaks.
Wall bath mixer system Rough in
Product code
RMOS150RH Wall bath mixer system 150mm
RMOS200RH Wall bath mixer system 200mm
RMOS250RH Wall bath mixer system 250mm
RMOS150RH-V Wall bath mixer system 150mm – Vertex
RMOS200RH-V Wall bath mixer system 200mm – Vertex
RMOS250RH-V Wall bath mixer system 250mm – Vertex
Rough in plumbing
- Prior to installing calculate the finished wall thickness, maximum is 30mm thick. Contact manufacturer for further options.
- If Wall thickness is greater than 30mm, contact manufacturer for further options.
- Prepare a Nogging to be fixed parallel between the Wall Studs.
- The Nogging must be fitted to enable the base of the Masterfit to be 30-32mm back from the Stud Face.
- The Masterfit will be marked “This side Up” to indicate orientation.
- Using the screws (x4) provided, mount the Masterfit to the Nogging. Ensure the Master fit is level and square.
Pipe connections
- The Hot and Cold ports are marked on the Masterfit. (Mixers have individual Hot/Cold inlet ports).
- Flush all water feed lines. All lines must be free from any dirt and debris before connecting to the Masterfit.
- Connect Hot and Cold lines to the corresponding 1/2” BSP ports of the Masterfit. (see Drawing)
- Do not remove any factory fitted pressure plugs or Fixings.
- Once all water connections are made, check Hot/Cold water flow by operating the Mixer Cartridge.
- Check all fittings and fixtures for leaks.
- Leave the Mixer(s) in the closed position and replace the Mixer protective cover.
- Store the Dress Kit in a safe place until required (see Dress Finishing Guide)
Plumbers note
- On-site high pressure line testing must be conducted with the Mixer in the closed position. (STATIC TEST ONLY )
- Under no circumstances is the Mixer to be opened when exceeding the maximum stated water pressure.
- At the completion of the testing, do not relieve any high pressure by opening the Mixer.
- Exposing the internals of the Mixer Cartridge to higher than specified water pressures, will void the manufacturer’s warranty
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS
3500:2003
Recommended working water pressure 300-500 kpa. Maximum water temperature is
65 deg.c
Copyright © Sussex Taps.
Read User Manual Online (PDF format)