WMF 5000 S+ planning information – Dynamic Milk
|
---|---
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF GmbH | WMF Platz 1 | 73312 Geislingen (Steige)
Conditions for usage and installation
Any necessary on-site preparatory work for electricity, water, and drainage
connections at the customer‘s premises is to be arranged by the machine
owner/operator.
The work must be carried out by authorized installation technicians in
compliance with general, country-specific, and local regulations. The WMF
service engineers may only connect the coffee machine to existing prepared
connection points. WMF Service is neither authorized nor responsible for
carrying out any on-site installation work prior to connection. The potential
equalization terminal is installed by WMF Service if needed
Dimensions and empty weight| Width Height Depth
Clearance heights Weight| 325 mm 716 mm 590 mm 72 – 169 mm Approx. 37
kg (depending on the model)
---|---|---
Water supply| Water supply line| 3/8 inch hose connector with mains tap, and
filter
| with 0.08 mm mesh size, on-site. At least 0.2 MPa (2 bar) supply
| pressure at 2 l/min. Maximum 0.6 MPa (6 bar).
Inlet temperature| Maximum 35 °C.
Water drain tube| Hose a minimum of DN 19, a minimum downward slope of 2 cm/m
Use at
elevation
above sea level| <2000m| |
Electrical data| Nominal power rating| 3.01 – 3.51 kW| 8.41 -9.96 kW
Power supply| 220 -240 V| 380 – 415 V
| 50 / 60 Hz (1 / N / PE)| 50 / 60 Hz (3 / N / PE)
Degree of protection| IP X0
Protection Class| I
Installation Clearance| For operating, service, and safety reasons the machine
should be installed with a clearance from the building or non- WMF components
of not less than 50 mm at the sides and 60 mm at the back. A minimum working
space of 800 mm in front of the coffee machine is recommended. Clearance of
at least 200 mm above the product hopper is recommended. The height of the
installation surface above the floor is at least 850 mm. If the coffee machine
connections are to be run downwards through the counter, please make space for
the lines, which can reduce the usable space below the machine. Additional
space for grounds through the counter needs to be considered on-site if
necessary. If the coffee machine is operated with a water filter the
additional space under the machine depending on the filter size has to be
considered. For further information see filter instructions.
If the machine is equipped with the cleaning system Auto Clean additional
space for the cleaning bottle under the counter needs to be considered (WxDxH
120x120x360 mm) Auto Clean cleaning hose is routed through the existing
counter cut out to the back of the machine.
Extension of the cut-out is not necessary.
Ventilation| If ventilation possibility is limited sufficient ventilation
needs to be provided e.g machine on feet extension, active ventilation, and
additional ventilation slots/ openings in the counter area.
Ventilation slots must not be covered. Under certain circumstances forced
ventilation on site is necessary to ensure heat dissipation.
Installation surface /water spray| The device must be placed and leveled on a
horizontal, sturdy, water-resistant, and heatproof base. The device must not
be cleaned using a water jet. The device must be installed where it is
protected against water spray. The device must not be located on a surface
that is sprayed or cleaned with a water hose, steam jets, steam cleaner, or
similar devices.
Electrical connection| These specifications for the electrical connection and
the standards quoted apply for connecting the coffee machine in EU countries.
It may be necessary to also observe additional country-specific regulations.
Outside the EU countries, acceptance of the standards quoted is to be checked
by the legal entity or natural person who wishes to use the coffee machine.
The customer’s on-site electrical system must be designed to meet country-
specific regulations per IEC 60364 and must match the information on the
rating plate. An isolated ground socket or a country-specific single-phase
socket for a single-phase connection, a 5-pole CEE / CEKON socket per DIN EN
50310 VDE 0800–2-310 or a country-specific multi-pole socket for a three-phase
connection, must be available near the machine. The sockets are part of the
customer‘s on-site installation.
The main cable must not come into contact with hot surfaces. If the mains
cable for this device is damaged then it must be replaced by our service
personnel or a similarly qualified person, in order to prevent hazards. In
order to avoid possible faults from arising in our shielded data lines due to
potential equalization currents between the devices, an additional potential
equalization unit should be planned for devices connected to the vending
system (see DIN EN 50310 VDE 0800– 2-310). If the machine is intended to be
installed in a large kitchen, it is recommended that it be equipped with a
ground potential bonding conductor. The potential equalization terminal is
installed by WMF Service if needed.
Water supply and drainage| The water supply must be located close to the
machine (max. distance of 800 mm). An anytime easily accessible and
sufficiently dimensioned water tap (preferably a ball tap), as well as a dirt
filter with a mesh size of 0,080 mm, must be installed below the counter in
the water supply. For connection from below through the counter, a cut-out
must be made in the hatched area on-site according to the drawing (see top
view). For drinking water with carbonate hardness above 5°dKH (carbonate
hardness), a WMF water filter should be fitted upstream. If the coffee machine
is connected to a drain connection, a funnel siphon must be installed in the
drain pipe. Please observe that the free drain (funnel siphon with sheet metal
angle) is fitted vertically. This means that it must always be vertical to the
water back pressure level that is reached. It must be fitted in a way that the
given gradient of the drain hoses (2%) is observed. Additionally, the free
drain must always be below the drains of the coffee machine and above the
actual drain pipe connections (HT40, HT50 or similar) with respect to its
height. To a funnel siphon with sheet metal angle max. two coffee machines
with DN19 hose and black silicone fabric hose should be connected. Other
devices (dishwasher, sink, etc.) should be installed elsewhere. The free drain
incl. hoses must not be exposed to heavy tensile, pressure, or torsional load.
Hereby, the damage might be caused to the mechanical components of the free
drain. Consequently, its usability may get lost. The on-site preliminary works
for the drainage connection must be commissioned by the operator of the
machine. They must be carried out by concession plumbers in compliance with
the prevailing, national as well as local regulations. The following drawings
serve to illustrate the drains and do not include any other connections, such
as power or water infeed!
Miscellaneous| Ambient temperature| +5 °C to maximum +35 °C (empty the water
system in case of frost).
---|---|---
| Maximum humidity| 80 of relative humidity without condensation. Do not use
the device outdoors.
| Heat dissipation| 0.1 kWh/h standby mode
3.25 kWh/h maximum USC| 0.1 kWh/h standby mode
9.25 kWh/h maximum USC
| Continuous sound
pressure lox! (LPA)| < 70 dB(A)
For more information as the instruction manual, safety data sheets, and
certificates, see:
http://mediacenter.wmf.com/servicecenter/
All information refers to coffee machines/ equipment as the standard version.
Individual solutions can differ from the standard version.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF GmbH | WMF Platz 1 | 73312 Geislingen (Steige)