B E G PD2-M-2C-12-48V-RR LUXOMAT Presence Detector Instruction Manual
Mounting-Instructions Preparations
Work on the mains supply may only be carried out by qualified professionals
or by instructed persons under the direction and supervision of qualified
skilled electrical personnel in accordance with electrotechnical regulations.
Disconnect supply before installing!
This device is not to be used to isolate other equipment from the mains
supply.
Operation
The device is a remote control-capable occupancy detector for ceiling mounting (interior applications) having a circular detection area.
Occupancy detectors automatically control the light, based on people being present (motion) and on the ambient light level (full automatic mode). The integrated light sensor constantly measures the ambient light and compares it with the switch-on threshold on the detector. If the ambient light is sufficient, lighting will not be switched. If the ambient light level is below the switch-on threshold, a movement activates the lighting in the room.
Mounting
Exclude sources of interference
In case the detection area of the detector is too large or areas are being covered that should not be monitored, the range can be reduced or limited by using the enclosed blinds.
Self-test cycle
The product enters an initial 60- second self-test cycle when the supply is first connected (LEDs flash).
LED function indicators after each mains recovery
Factory setting active
- White, red and green flash in quick succession for 10sec., then initialisation indicators,- see below
Standard mode
- Detector programmed
- red flashes quickly (2x/sec.)
- Detector not programmed
- red flashes (1x/sec.)
LED function indicators
Motion detection
- red flashes
Light value higher than switchon threshold:
- green LED flashes
Impulse mode active
- red and green flash once all 4 s
Corridor function active:
- white LED ON 1 s and OFF 4 s
Semi-automatic mode active:
- white LED shines permanent
Light measurement active:
- Green flashes once every 10 s
Hardware Reset/ factory settings
Reset: The setting of the potentiometers to “test” and “sun” from any other position causes a reset of the device. That means all other settings are reset to factory settings (fast flashing of all LEDs for 5 seconds).
EU Declaration of conformity
This product respects the directives concerning
- electromagnetic compatibility (2014/30/EU)
- low voltage (2014/35/EU)
- restriction of the use of certain hazardous substances in electrical and electronic equipment (2011/65/EU)
Accessory
- Remote control IR-PD-2C
- Remote control IR-PD-Mini
- IR-Adapter for Smartphones
- Wire basket BSK (Ø 200 x 90 mm)
- SM socket IP54
Technical data
- Voltage
- Power input
- Terminal clamps: for solid one-wire conductors
- Area of coverage
- Mounting height min./max./ recommended
- Monitored surface for tangential approach and 2.5 m mounting height
- Range of coverage at 2.5 m mounting height and 18°C ambient temperature
- tangential
- towards
- seated
- Class / Degree of protection
- Dimensions H x Ø
- Ambient temperature
- Housing
- remote control-capable
Channel 1 (lighting control)
- Relay contact Switching power
- Type of contact: 1x µ-contact, dry NO contact
- Mixed light measuring
- Factory settings
Channel 2 (HVAC control) – motion-dependent
- Relay contact Switching power
- Type of contact: 1x µ-contact, dry NO contact
- Factory settings
- A follow-up time of > 15 min being chosen, the switch-on delay of 5 minutes is active
**Settings via potentiometers
A = 15 s – 16 min/Test/
B = 10 – 2000 Lux
C = 5 – 120 min/ Alarm(e)/**
Follow-up time channel 1 Switch-on threshold channel 1 Follow-up time channel
2 The setting 10 Lux corresponds to the potentiometer setting „moon“. With
setting „sun“ only motion detection, no light evaluation.
Wiring diagram
Schematic diagram – when connecting the detector, please respect the labelling
of the terminal connections at the detector!
- Set channel 2 of the slave device to pulse mode.
- Max use one push-button and one slave device per master.
- X1 Light channel
- X2 HVAC
Additional functions
For a description of all functions please consult the operation manual:
References
- Home - B.E.G.
- B.E.G. - The lighting control professionals
- B.E.G. - The lighting control professionals
- B.E.G. - The lighting control professionals