CLiCK GridPro Dimmer Mounting Kit

Dimmer Kit Yoke Mounting Instructions

  • Isolate mains supply before commencing any work

  • Ensure back box is correctly positioned i.e. box must be flush to the wall.

  • Assemble all dimmers on to yoke using nut runner tool and locking nut. (Fig.4)
    All dimmers should be assembled on to yoke before attaching the yoke to the back box
    Dimmer is assembled from the back

  • Do Not attach yokes to back box until all dimmers are attached and wired according to instructions. (Fig.5)
    For ease of installation it is recommended that all dimmers are installed first prior to other Grid Pro modules
    Mounting Instructions

  • Wire Dimmers according to instructions.

  • Ensure mounting yoke is earthed correctly using the earth terminal provided.

  • When all dimmers are assembled attach mounting yoke to suitable fixed back box according to the Yoke Attachment Instructions supplied with the yoke.

  • Ensure mounting yoke is earthed correctly using the earth terminal provided.

  • Arrange cables through the mounting yoke and connect the remaining modules according to the General Installation Instructions (supplied with Yokes).

  • Check all connections thoroughly.

  • When the installation is complete attach front plate according to the Front Plate Attachment Instructions supplied with the front plate.

  • Do not overtighten the fixing screws.

  • Turn on mains supply to check operation of installation.

  • For cleaning / polishing of products, use only a soft, dry, clean cloth

Note: When mounting dimmers on to multi-tier plates, only dimmers less than 60 mm in height must be used. Please speak to our technical team who will be able to assist.

Safety Information

Please read the following information carefully before commencing installation.

Before commencing any electrical work, to prevent the possibility of receiving an electric shock, ensure the mains isolator on the consumer unit is in the ‘OFF’ position and safely isolated in accordance with Best Practice Guide 3.

If in doubt consult a qualified electrician. The accessory plate must be installed in accordance with the latest IET Wiring Regulations, BS7671.

If this product is being fitted as a replacement part to an existing installation account must be taken to the version of the wiring regulations it was installed to.

Dimmer Mounting on to 1 – 4 Gang Plates (Mode, Polar, Deco, Deco+, Metalclad, Define)

  • Please note all 1-4 gang GridPro front plates can be mounted in any British Standard BS4662 flush mounted boxes. The product can also be surface mounted using the standard Click Mode or Polar Back boxes.

  • Isolate mains supply.

  • Ensure the depth of the back box is the correct size for the installation (47mm deep) and is securely fixed to the wall.

  • When using a 1 Gang Plate it may be necessary to bend back or remove the top and bottom lug of the back box if present. Alternatively you may find it easier to remove the clip feature on the module but this will make the module incompatible with the GridPro yoke.

  • Assemble dimmer on to the mounting kit via the supplied locking nut and nut runner tool. (Fig1.)
    Dimmer Mounting
    Please note that the dimmer spindle may be offset so the orientation of the dimmer will need to be taken into account to achieve the desired assembled position. (Fig.2)
    Overhanging dimmer does not allow room for adjacent module
    Dimmer Mounting
    Rotating dimmer on the offset spindle moves the overhang to the other side to allow adjacent module to be fitted
    Dimmer Mounting

  • Depending on the size of dimmer then a twin mounting kit may be required. (Fig.3)
    For larger dimmer modules a twin mounting kit could be required
    Dimmer Mounting
    This allows the dimmer to be fitted by sacrificing the module space next to it
    Dimmer Mounting

  • Cable dimmer module according to instructions.

  • Check all connections thoroughly.

  • Mount accessory taking care to avoid trapping any cables. Do not overtighten the fixing screws.

  • Turn on mains supply to check operation of accessory

Note: When mounting dimmers on to multi-tier plates, only dimmers less than 60mm in height must be used. Please speak to our technical team who will be able to assist.