FDF E750 Cycle UBE FluidExercise User Guide
- June 12, 2024
- FDF
Table of Contents
FDF E750 Cycle UBE FluidExercise User Guide
Introduction
Training with the E750
Congratulations on your purchase of E750.
FIRST DEGREE FITNESS is proud to present the Unit as a full commercial use
product featuring patented Adjustable Fluid Resistance.
As with any piece of fitness equipment, consult a physician before beginning your E750 exercise program.
Follow all instructions carefully for correct assembly, Tank filling, Water Treatment, service and safety.
Access to our world-wide distributor and service network is available at www.firstdegreefitness.com
Check contents to assure all parts are present and correct prior to assembly.
CAUTION
Use two hands and follow all safety instructions whenever raising or lowering the E750 control arm.
Warning
Do not remove feet or hands while crank is in motion. The crank will continue
to rotate and could cause injury
Safety
Safety Information
- Before using this product, it is essential to read this ENTIRE operation manual and ALL instructions. The Unit is intended for use solely in the manner described in this manual.
- UNDERSTANDING EACH AND EVERY WARNING TO THE FULLEST IS IMPORTANT
- As with any piece of fitness equipment, consult a physician before beginning your Unit exercise program.
- Please be aware that any fitness regiment, before being undertaken, is best preceded by a physical checkup from a certified physician.
- Injuries to health may result from incorrect or excessive training.
- WARNING Heart rate monitoring systems may be inaccurate. Over exercise may result in serious injury or death. If you feel faint, stop exercising immediately.
- Do not allow children unattended access to the machine.
- Please keep hands away from moving parts, as indicated by the warning label on th Main Frame of your machine.
- If any of the adjustment devices are left projecting, they could interfere with the user‟s movement.
- Do not store in freezing conditions with water in the Tank as it can expand and crack the components.
Installation
- Place on a stable, flat surface in a horizontal position during use for maximum stability.
- Check regularly and follow all instructions for maintenance as specified in this manual.
- Replace immediately any defective parts and do not operate unit until all repairs are complete.
Proper Usage
- Turn the Seat to the side BEFORE entering AND exiting the unit.
- Do not use any equipment in any way other than designed or intended by the manufacturer. It is imperative that FIRST DEGREE FITNESS equipment is used properly to avoid injury.
- Injuries may result if exercising improperly or excessively. It is recommended that all individuals consult a physician prior to commencing an exercise program. If at any time during exercise you feel faint, dizzy or experience pain, STOP EXERCISING and consult your physician.
- Keep body parts (hands, feet, hair, etc.), clothing and jewelry away from moving parts to avoid injury.
- Follow instructions provided in this manual for correct foot position and basic rowing techniques.
- For more detailed rowing techniques, please refer to our International website www.firstdegreefitness.com
Inspection
- DO NOT use or permit use of any equipment that is damaged and/or has worn or broken parts. For all FIRST DEGREE FITNESS equipment use only replacement parts supplied by FIRST DEGREE FITNESS.
- EQUIPMENT MAINTENANCE – Preventative maintenance is the key to smooth operating equipment as well as to keep your liability to a minimum. Equipment needs to be inspected at regular intervals.
- Ensure that any person(s) making adjustments or performing maintenance or repair of any kind is qualified to do so.
- DO NOT ATTEMPT TO USE OR REPAIR ANY ACCESSORY APPROVED FOR USE WITH THE FIRST DEGREE FITNESS EQUIPMENT WHICH APPEARS TO BE DAMAGED OR WORN.
- Check regularly and follow all instructions for maintenance as specified in this manual.
- Replace immediately any defective parts and do not operate unit until all repairs are complete.
Operating Warnings
- Keep children away from the equipment. Parents or others supervising children must provide close supervision of children if the equipment is used in the presence of children.
- Do not allow users to wear loose fitting clothing or jewelry while using equipment. It is also recommended to have users secure long hair back and up to avoid contact with moving parts.
- **** All bystanders must stay clear of all users, moving parts and attached accessories and components while machine is in operation.
- WARNING Do not insert fingers into Tank
Assembly
Product Specifications
- Product Class : SC
- Note : Class SC crank training equipment is not suitable for high accuracy purposes
- Braking System : Speed Independent
- Product Net Weight: 104.4kg (230.16lb)
- Product Gross Weight : 123.8kg (272.93lb)
- Maximum Safe Operating Surface Area : 253cm (99.61”) Length x 217cm (85.43”) Width
- Dimensions: 1330mm (52.36”) Length x 970mm (38.19”) Width x 1520mm (59.84”) Height
- Maximum User Weight : 150kg (330lb)
- Footprint :1930mm x 1570mm or upright 1520mm x 970mm
For indoor use
Product Highlights
Live area and Training area
Box Contents
Item | Qty. | Description | Item | Qty. | Description |
---|---|---|---|---|---|
1 | 1 | Main Frame | 8 | 1 | Right Crank Pedal |
2 | 1 | Lower Seat Frame | 9 | 1 | Seat Frame lubricating grease |
3 | 1 | Upper Seat Frame | 10 | 1 | Multi-Tool |
4 | 1 | Seat Back | 11 | 2 | D Cell Battery |
5 | 1 | Lower Seat | 12 | 1 | Touch Up Paint |
6 | 1 | L-pin | 13 | 1 | Funnel and Hose |
7 | 3 | Leveler | 14 | 1 | Owners Manual |
Hardware Kit
15| 8| M6x20mm Bolt| 20| 5| M10 Nylock Nut
16| 5| M10x25mm Bolt| 21| 1| 4mm Allen Key
17| 8| M6 Washer| 22| 1| 6mm Allen Key
18| 10| M10 Washer| 23| 4| Water Treatment Tablet
19| 1| M10 Plastic Washer| | |
Support Kit
24| 1| Dome Head Bolt M8x55| 27| 2| M8 Nyloc Nut
25| 1| Dome Head Bolt M8x90| 28| 1| Support Plate
26| 2| Washer M8x16x1t| | |
Assembly Instructions
STEP 1
REQUIRED
- Upper Seat Frame [3]
- Seat Back [4]
- Lower Seat [5]
- 8 x M6 x 20mm Blots [15]
- 8 x M6 Washers [17]
Assembly Seat Back and Lower Seat
a) Seat Back[4] to Upper Seat Frame[3] using 4x M6x20mm Bolts[15] and 4x
M6 Washers[17].
b) Lower Seat[5] to Upper Seat Frame[3] using 4x M6x20mm Bolts[15] and 4x
M6 Washers[17].
STEP 2
REQUIRED
- Main Frame [1]
- Lower Seat Frame [2]
- 3 x Foot Levelers [7]
- 4 x M10 x 25mm Blots [16]
- 8 x M10 Washers [18]
- 4 x M10 Nyloc Nuts [20]
Assembly Main Frame and Lower Seat Frame
a) Attach Lower Seat Frame[2] to Main Frame[1] using 4x M10x25mm
Bolts[16], 4x M10 Nyloc Nuts[20] and 8x M10 Washers[18].
b) Thread the 3x Foot levelers[7] into underside of base. Adjust as
required.
STEP 3
REQUIRED
- Main Frame [1]
- Upper Seat Frame [3]
- L– Pin [6]
- M10 x 25mm Blots [16]
- 2 x M10 Washers [18]
- M10 Plastic Washers [19]
- M10 Nyloc Nuts [20]
Assembly Upper Seat Frame and Lower Seat Frame
Upper Seat Frame[3] onto Main Frame[1] and secure using 1x M10x25mm
Bolt[16],1x M10 Nyloc Nut[20], 2xM10 Washers [18], M10 Plastic Washer[19] and
L-pin[6].
Note : Tighten the M10x25mm Bolt, Washers and Nyloc until lightly snug only. Over-tightening will prevent the seat from rotating. Use the L-pin to tighten the Upper Seat Frame once rotated into place
STEP 4
REQUIRED
Right Crank Pedal [8]
Assembly Right Crank Pedal
Secure Right Crank Pedal[8] onto Crank arm. The Pedal threads have a blue
coating which will feel very tight when threaded onto the crank arm. This is a
type of thread locker, and once in contact with the crank arm threads will
activate in approximately 15minutes.
CAUTION
Extreme over-tightening could damage the aluminum threads on the crank arm
Note : Allow 15 minutes for the thread-locker to activate before first time use.
Check pedal tightness on a regular basis and tighten as needed with a 15mm wrench
STEP 5
REQUIRED
- M8x55 Bolt[24]
- M8x90 Bolt[25]
- 2 x M8 Washer[26]
- 2 x M8 Nyloc Nut[27]
- Support Plate[28]
Support Kit Assembly
Let the machine lie down carefully.
Assemble the Support Plate[28] using M8x55 Bolt[24] and M8 Washer[26] and M8
Nyloc Nut[27].
Stand the machine.
Assemble the M8x90 Bolt[25],M8 Washer[26] and M8 Nyloc Nut[27] on the side of
Support Plate.
Operation Instructions
E750 Control Arm
Chain Tensioning Bolts : Allows for tightening the chain or adjustment from side to side. Make sure when tightening only to adjust the same amount for both Bolts, otherwise the sprocket will be misaligned.
Note : Tightening the right Bolt only will pull the right side of the crank assembly toward you, tightening the left will pull the left side toward you. Use this feature to realign the rear with the front sprocket if needed or when changing to a new chain.
Crank Arm Bolts: Loosen all 8 Bolts slightly before adjusting/ tightening chain.
The E750 Pedal: This patented design allows for usage in both the recumbent position and for sitting/standing upper body workouts.
T-Pin : The T-Pin locks the control arm in any one of 72 different positions throughout its 360 degree range of motion. Pull up the T-pin to allow the control arm to rotate while supporting the control arm with the other hand
L-Pin: Loosen when rotating the control arm and tighten (snug only) once the desired position has been reached.
Inspection plate: Open to check chain tension.
Warning : Do not check chain tension by hand!
Tank Filling and Water Treatment
REQUIRED
Funnel and Hose[13]
a) Filling requires a large bucket (not supplied) and the supplied water
Funnel and Hose[13]. Filling will take approximately 8 liters of water.
b) Open the Tank Plug on the back of Tank and insert hose (rotating the
impeller slightly may be necessary to allow the hose to pass). In areas where
tap water quality is known to be poor, FD F recommends the use of distilled
water.
c) Move the Tank adjuster handle to level 10 and begin filling. Do not
fill the Tank higher than the level indicator on the front of the clear shell.
d) Once filling is complete follow the Water Treatment schedule below.
NOTE
In areas where tap water quality is known to be poor, FDF recommends the use
of distilled water
WARNING Impeller blades are sharp! Do not Place fingers in Tank to adjust impeller position.
It is recommended to use the end of the hose should the impeller require adjustment
Note : The Lower Tank Plug is Permanently Sealed
NOTE : For simple, fast and efficient filling and/or drainage of the Fluid Tank, we have a battery operated pump (rechargeable via USB) available as an option. We recommend this to any commercial facility, with multiple units, that has a need to drain and refill Tanks from time to time. To purchase, contact your nearest First Degree Fitness distributor or go to our website on www.firstdegreefitness.com for details.
INITIAL WATER TREATMENT
Add One Water Treatment Tablet per full Tank. Do NOT, UNDER ANY CIRCUMSTANCE,
USE A WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED WITH YOUR UNIT. Your
unit purchase includes 4xWater Treatment Tablets, which is sufficient for
several years of use.
To purchase additional Water Treatment Tablets, please consult your nearest regional dealer/distributor or check our website at www.firstdegreefitness.com
CHANGING RESISTANCE LEVEL
Changing resistance on your Unit is simple. The level of resistance is determined by the level indicator located on the front of the Tank. Level one indicates lightest resistance, level ten represents heaviest resistance. The Tank‟s variable fluid resistance technology ensures an instant catch and constant resistance throughout the movement.
Your Unit Monitor will automatically adjust to the resistance level selected
on the Tank. Allow three to four seconds after adjusting resistance handle for
the correct resistance level to be achieved.
LONG-TERM WATER TREATMENT
WARNING: DO NOT USE ANY OTHER WATER TREATMENT TABLET OTHER THAN THOSE SUPPLIED
WITH YOUR UNIT.
The amount of time between water treatments can vary greatly depending on your unit‟s location and exposure to sunlight. Typically you can expect to treat your Tank water every 12-24 months. If water becomes discolored or shows signs of algae / bacterial growth simply add one Water Treatment Tablet.
Bluetooth Auto-Adjust Monitor
Auto Start: Commence exercise to activate.
Reset all values : Press and hold RESET button for 3 seconds.
Auto Power Down : Over 5 minutes. All values revert to zero after
restart.
WATT : Measures peak power in watts, calculating the strength and acceleration provided to accurately measure a user‟s power.
TRAINING DATA : Data gathered from each workout is displayed in a power curve and cumulative power graph, enabling real-time comparisons for effective progressive training.
AUTO ADJUST LEVEL: Built in potentiometer automatically adjusts the Monitor‟s resistance level according to the position of the Fluid Force Lever on the tank .
BLUETOOTH CONNECTIVITY: Each unit is fitted with the most advanced Monitor technology, enabling Bluetooth connectivity with any compatible smart device. The Monitor will assist with effective training progression, capturing and comparing data for the competitive individual. It is compatible with 3rd party APP and Software Update via Bluetooth.
NOTE: Heart Rate Chest Strap is sold separately.
BATTERY WARNING: To prevent batteries from leaking, remove them from the console if you plan on not using the equipment for more then 30 days.
WARNING:
Heart rate monitoring systems may be inaccurate, Over exercising may result in serious injury or death. If you feel faint stop exercising immediately and seek professional medical advice.
Calibration Procedure
Press and hold 「RESET」and「REST」for 5 seconds. Display will show “ Level 1“
-
Turn handle to Level 1.
-
Press Reset.
-
Display will now show Level 2.
-
Level 1 Calibration is complete.
-
Turn handle to Level 2.
-
Press Reset.
-
Display will now show Level 3.
-
Level 2 Calibration is complete.
Repeat for 3,4,5,6,7,8,9,10. Level 10 Press Reset.
Repeat the steps back to level 1. Calibration is complete.
Maintenance & Troubleshooting
For further information, manuals and warranty requests visit www.firstdegreefitness.com/support
Problem | Solution |
---|---|
Water changer color or becomes cloudy. | Change Unit location to reduce direct |
exposure to sunlight. Add water treatment or change Tank water as directed in
the water treatment section of this manual. Consider using distilled water to
refill Tank.
I want to drain the fluid Tank on my E750.| It is recommended to take your
unit outdoors, open the Tank Plug, and lay unit on its back to facilitate
draining process. For simple, fast and efficient filling and/or drainage of
the Fluid Tank, we have a battery operated pump (rechargeable via USB)
available as an option. We recommend this to any commercial facility, with
multiple units, that has a need to drain and refill Tanks from time to time.
To purchase, contact your nearest First Degree Fitness distributor or go to
our website on www.firstdegreefitness.com
for details.
The Monitor display is erratic and illuminates, but does not register with
movement.| It is possible that there is a loose connection. Check that the
Monitor lead is connected properly to the unit. If connected properly check
Sensor gap. Contact your local dealer if this fails to address the problem.
The Monitor does not illuminate after battery installation.| Replace/reinstall
batteries in correct position and try again. If the LCD screen fails to
illuminate, try rotating the batteries slightly in the Monitor.If this fails,
contact your local service center.
The Monitor LEVEL is not synchronized with the Tank LEVEL.| The Monitor LEVEL
needs to be recalibrated. Please refer to “Calibration Procedure” page 15 of
this manual.
Knocking noise from inside the control arm while training, especially when
changing directions.Chain requires tightening or adjustment.| Open Inspection
Plate located on front of Control Arm and check tension using a screwdriver or
other tool. Use the Chain Tensioning Bolts located at the rear of the Control
Arm to tighten or adjust as needed. The chain should have approx. 3mm of slack
when properly adjusted. See P.11 for details.
Pedal is loose (either left or right) and cannot be retightened.Aluminum crank
arm threads are stripped.| Contact service center for replacement. Then check
weekly as recommended.
Pedals slip during hard training. PK Tank Belt requires tightening.| Remove
large Inspection Plate next to the Tank, insert a long tool to push the rear
end cap out from the inside, exposing the Tank Belt Tensioning Bolt. Loosen
Tank Bolts slightly.Remove upper Rubber Belt Cover to expose the PK Belt.
Tighten the Tank Tensioning Bolt until the Belt is too tight to be twisted
from side to side more than 45 degrees by hand.
Item| Time Frame| I nstru c ti on s
---|---|---
Seat and Frame.| Weekly.| Wipe down weekly with lint free cloth or more often
with heavy club use.
PK Belt Tension.| Monthly.| Check monthly for signs of slippage.
Adjust/tighten as required.
Tank and Water Treatment.| 12 months to 2 years.| Follow instructions as
specified in the “Water Treatment” section of this manual.
Chain Drive.| Check every 100 hours for correct tension.| Open the inspection
plate and check tension using a screwdriver or other tool. Tighten as required
using Chain Tensioning Bolts located at the end of the Control Arm.
Handle Assembly.| Check weekly using Multi-Tool (supplied) toensure Handle
Assembly is securely tightened into Crank Arm.| The Handle should be checked
on a regular basis. Continued use of a loose Handgrip can causedamage to the
Crank Arm threads, necessitating replacement.
To ensure maximum lifespan and optimal performance follow these steps:
- Keep your E750 in a dry, clean climate controlled environment at room temperature.
- Only treat water with FDF genuine Water Treatment Tablets. Refer to „Water Treatment‟ section on page 12.
- Periodically clean your machine with disinfectant, applied using a lint free cloth.
- Wipe dust off the machine.
- For information on how to service your machine visit firstdegreefitness.com/support
Tank Belt Adjustment
-
Remove large metal inspection plate.
-
Using a long tool, push out the rear end cap as pictured below left. This will give you access to the Tank tensioning Bolt (shown lower right).
-
Loosen both the rear and front Tank Bolts slightly as shown. Remove front Rubber Belt Cover.
-
Using a 6mm Allen Key, tighten the Belt using the Tank Tensioning Bolt until the belt no longer slips during hard rowing.
Note : Do not over tighten Tank Bolts.
Tip : Twist the Belt by hand to gauge tightness. Correct tension should be obtained when no longer able to twist more than 45 degrees
International Warranty
FULL COMMERCIAL USE
This product is designed and constructed for use in any Health Club / Fitness
Studio application. First Degree Fitness Limited warrants that the E750 Cycle
XT (model E750), purchased from an authorized agent and in its undamaged
original packaging, is free from defects in materials and workmanship. First
Degree Fitness Limited or its agent will, at their discretion, repair or
replace parts that become defective within the warranty period, subject to the
specific inclusions and exclusions below.
Metal Frame – 10 Year Limited Warranty
First Degree Fitness will repair or replace the metal Main Frame should it
fail due to any defect in materials or workmanship within 10 years of the
original purchase. Warranty does not apply to frame coating.
Polycarbonate Tank & Seals – 5 Year Limited Warranty
First Degree Fitness will repair or replace the polycarbonate Tank or seals
should they fail due to any defect in materials or workmanship within 5 years
of the original purchase.
Mechanical Components (of a non-wearing nature) – 2 Year Limited Warranty
First Degree Fitness will repair or replace any mechanical component should it
fail due to any defect in materials or workmanship within 2 years of the
original purchase.
All Other Components (of a wearing nature) – 2 Year Limited Warranty
First Degree Fitness will repair or replace any component should it fail due
to any defect in materials or workmanship within 2 year of the original
purchase.
Specific Inclusions
- Pedals & toe straps
- Hand grip assemblies
- Seat
- All rubber components
- Monitor & speed Sensor (excluding replaceable batteries)
- All drive belts & chains
- Crank arms
- All pulleys, rollers & bearings
General Exclusions
- Damage to the finish of any part of the machine
- Damage due to neglect, abuse, incorrect assembly or use of the machine
- Any charges for freight or customs clearance associated with the return or dispatch of parts
- Any damage to or loss of goods during transport of any kind
- Any labour cost associated with a warranty claim
General Conditions
- The serial number of the machine must be correctly registered with First Degree Fitness Limited or one of its appointed distributors
- First Degree Fitness Limited reserve the right to examine any part where replacement is claimed under warranty
- Warranty commences at time of sale but no later than six (6) months from date of original shipment
- Warranty period applies only to the original purchaser from the date of purchase and is not transferable
- The product must be returned to your place of purchase in original packaging with transportation, insurance and associated charges paid for by you and risk of loss or damage assumed by you
- First Degree Fitness makes no other warranties except as stated here and expressly disclaims all warranties not stated in this warranty. Neither First Degree Fitness nor its associates shall be responsible for incidental or consequential damages
- Manufacturer’s warranty automatically commences upon sale of the product to end user or upon the expiration of one (1) year from month of manufacture, whichever occurs first
NOUS CONTACTER
Pour le soutien à la clientèle, veuillez
visiter
firstdegreefitness.com/support
TAÏWAN
T: +886 3 478 3306
764 Chung Shan South Rd
Yangmei Taoyuan
Taiwan R.O.C.
References
Read User Manual Online (PDF format)