FDF E316 and VX-2 Rowers Indoor Rowing User Manual

June 12, 2024
FDF

FDF E316 and VX-2 Rowers Indoor Rowing

FDF E316 and VX-2 Rowers Indoor Rowing product

Product Information

The Monitor and Sensor Troubleshooting Guide is applicable to E316 and VX-2 Rowers. It provides step-by-step instructions to resolve issues related to the monitor and sensor of the rowing machine. The guide helps in identifying and fixing problems such as no display on the monitor, abnormal readings, fluctuating readings, and incorrect time display.

Basic Checks:

  1. Monitor Displays Nothing: Check batteries and replace if necessary.
  2. Abnormal Readings: Monitor display is normal, but readings do not update during exercise or fluctuate inconsistently. Monitor displays 59:59 for 500mTime (Rowers Only).

These symptoms indicate a potential issue with the speed sensor assembly or the wiring between the sensor and monitor. To  resolve  the  issue  follow the  step‐by‐step  instructions  below  until  normal  function  resumes.

Troubleshooting

  • Step 1: Remove and replace batteries

Ensure to replace the batteries with new ones.

  • Step 2: Check Sensor Connector at rear of Monitor
  • Disconnect and re-connect the sensor cable.
  • Check for obvious sensor cable damage.
  • Re-test monitor input before proceeding.FDF E316 and VX-2 Rowers Indoor Rowing 02
  • Step 3: Remove the Rear Cover

Remove the rear cover by unscrewing the five fixing screws.

  • Step 4: Check cabling, connectors, and Sensor for correct fit or damage.

Ensure that all cables, connectors, and sensors are properly connected and undamaged.FDF E316 and VX-2 Rowers Indoor Rowing 04

  • Step 5: Check the 6 Magnets on the Sensor Wheel

Inspect the sensor wheel to ensure all six magnets are in place.

  • Step 6: Check sensor/sensor wheel gap
    Temporarily replace rear cover and check sensor/sensor wheel gap is between ~ 0.5 and 3mm. Closer is better. Adjust if necessary.

    • Temporarily replace the rear cover.
    • Ensure the sensor/sensor wheel gap is between approximately 0.5mm and 3mm.
    • Adjust the sensor position if necessary.FDF E316 and VX-2 Rowers Indoor Rowing 06
  • Step 7: Sensor Replacement

  1. 1. Disconnect and remove the old sensor.
  2. Install and connect the new sensor.
  3. Adjust the sensor/sensor wheel gap accordingly.
  4. Reinstall the rear cover.
  • Step 8: Replacing the Monitor (last resort)
  1. 1. Disconnect the connectors at the rear of the monitor.
  2. Remove the securing nut and bolt from the monitor support stalk.
  3. Replace with a new monitor.
  4. Reinstall the securing nut and bolt.
  5. Re-connect both connectors.

Note: Replacing the monitor should be considered as a last resort after exhausting all other troubleshooting steps.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)