HORIBA IR-400 Series Gas Monitor Instruction Manual

June 12, 2024
HORIBA

HORIBA IR-400 Series Gas Monitor Instruction Manual
HORIBA IR-400 Series Gas Monitor

Safety Instruction

Chamber cleaning end point monitoring for deposition process.
Overview

  • Reduce time for chamber cleans
  • Reduce usage of cleaning gases
  • Repeatable and predictable clean process
  • Longer lifetime of chamber components

Features

  • Multi gas monitoring
  • High sensitivity
  • Gas cell heating function
  • Analog/Digital communication
  • Multi-display

Product Specifications

Model IR-422 IR-432
Measurement gas and full scale SiF4: 100 mTorr, CF4: 100 mTorr WF6: 200
mTorr, NF3: 200 mTorr SiF4: 3800 mTorr
Cell length 200 mm 30 mm
Cell set temperature 180 ℃
Heater jacket Temperature sensor: Thermocouple K-type,

Thermostat: Manual   reset
Repeatability 1| ± 0.5 %F.S.
Linearity
1| ±1 %F.S.
Zero noise 1| ± 0.5 %F.S. (3σ)
Ambient temperature| 20 -35 ℃| 20 -50 ℃
Storage temperature| 0 -70 ℃
Warm-up time| ≥ 120 min
Wetted material| SUS316L, BaF2, FFKM| SUS316L, ZnSe, FFKM| SUS316L (Clean S® treatment AF type
2), BaF2, FFKM
Fitting| NW25
Leak rate| ≤ 1 × 10-6 Pa · m3/s (He)
Proof pressure| 300 kPa (A)
Analog communication| Analog output: 0 -5 VDC
Contact output: Error, High Low alarm, Warm-up status
Contact input: Zero calibration| Analog output: 4-20 mA
Contact output: Error, High Low alarm, Warm-up status
Contact input: Zero calibration
Digital communication| RS- 485 (F-Net Protocol)
Power supply| Sensor| 24 VDC, 1.5 A
Heater jacket| 208 V, 84 VA| 115 V, 132 VA
Dimensions (mm)| W433 × H117.5 × D83| W259 × H130 × D86
Weight| 3.2 kg| 2.8 kg

  1. The specifications are guaranteed under HORIBA STEC’s inspection conditions using calibration gas.
  2. Clean S is a registered trademark of Resonance Corporation.
Model IR-427 IR-437
Measurement gas and full scale SiF4: 100 mTorr, CF4: 100 mTorr WF6: 200
mTorr, NF3: 200 mTorr SiF4: 3800 mTorr
Cell length 200 mm 30 mm
Cell set temperature 180 ℃
Heater jacket Temperature sensor: Thermocouple K-type,

Thermostat: Manual   reset
Repeatability 1| ± 0.5 %F.S.
Linearity
1| ±1 %F.S.
Zero noise 1| ± 0.5 %F.S. (3σ)
Ambient temperature| 20 -35 ℃| 20 -50 ℃
Storage temperature| 0 -70 ℃
Warm-up time| ≥ 120 min
Wetted material| SUS316L, BaF2, FFKM| SUS316L, ZnSe, FFKM| SUS316L (Clean S® treatment AF type
2), BaF2, FFKM
Fitting| NW25
Leak rate| ≤ 1 × 10-6 Pa · m3/s (He)
Proof pressure| 300 kPa (A)
Digital communication| Ether CAT®     Protocol
Power supply| Sensor| 24 VDC, 1.5 A
Heater jacket| 208 V, 84 VA| 115 V, 132 VA
Dimensions (mm)| W433 × H117.5 × D83| W259 × H130 × D86
Weight| 3.2 kg| 2.8 kg

  1. The specifications are guaranteed under HORIBA STEC’s inspection conditions using calibration gas.
  2. Clean S is a registered trademark of Resonac Corporation.

Reliable, High-performance

Non-dispersive Infrared Absorptiometry (NDIR)
The infrared absorptiometry method employed by the IR-300 Series uses the principle of the absorption by gas molecules of the infrared light emitted from an infrared light source.
The sample output from a sample that has absorbed the gas being measured is compared to a reference output with no absorbance, and the result is converted into a gas
concentration.
The use of this double beam method enables long-term, stable measurement results to be obtained.
Diagram
Diagram

The optical system is made up of a light source, gas cell and double beam detectors.
The stability of the double beam detector has been proven over a period of more than 40 years.

Application Examples

Support products of exhaust line.

[Gas and vacuum monitoring]

  • IR-400 Series: Chamber cleaning end point monitoring for deposition process
  • VG Series: Pressure monitoring of exhaust line

[Pressure control]

  • PV Series: Chamber pressure control by N2 ballast control.

Exhaust Line

Disposal

| The HORIBA Group adopts IMS (Integrated Management System) which integrates Quality Management System ISO9001, Environmental Management System ISO14001,
and Occupational Health and Safety Management System ISO45001.
We have now integrated Business Continuity Management System ISO22301 in order to provide our products and services in a stable manner, even in emergencies.
---|---
| Applying to the EU RoHS Directive: This products is compliant with the restriction of the designated 10 hazardous substances(*). (I’) lead , cadmium , mercury , hexavalent chromium , polybrominated biphenyls (PBB) , polybrominated diphenyl ethers (PBDE) bis (2-ethylhexyl) phthalate (DEHP) , butyl benzyl phthalate (BBP) dibutyl phthalate (DBP) and isobutyl phthalate (DIBP).
Using lead-free soldering: Lead-free soldering is used for mounting components of printed circuit boards. – Many countries consider the reinforcement of regulations concerning the risk caused by lead to human body and the environment

  • The contents of this catalog are subject to change without prior notice, and without any subsequent liability to this company.
  • It is strictly forbidden to copy the content of this catalog in part or in full.
  • All brand names, product names and service names in this catalog are trademarks or registered trademarks of their respective companies.

Please read the operation manual before using this product to ensure safe and proper handling of the product

CUSTOMER SUPPORT

HEAD OFFICE
11-5, Hokotate-cho, Kamitoba, Minami-ku, Kyoto, 601-8116 Japan
Phone: (81) 75-693-2300 Fax: (81) 75-693-2350
U.S.A.
HORIBA Instruments Incorporated
Sunnyvale Office
Phone: (1) 408-730-4772 Fax: (1) 408-730-8975
Austin Office
Phone: (1) 512-836-9560  Fax: (1) 512-836-8054
Portland Office
Phone: (1) 503-624-9767  Fax: (1) 503-968-3236
HORIBA Reno Technology Center
Phone: (1) 775-358-2332  Fax: (1) 775-358-0434
horiba.com/semiconductor
Logo.png

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HORIBA User Manuals

Related Manuals